LEVIN GARAGE July 24, 2023 SDA Job# 9843 i <br /> Type of construction: LOW RISE-RESIDENTIAL Location: 1013 RUCKER AVE <br /> Applicable Building Codes:12021 IBC,ASCE 7-16 EVERETT,WA 98201 <br /> Work performed: LATERAL ONLY <br /> WIND DESIGN: <br /> Enclosure Classification: ENCLOSED-SIMPLE DIAPHRAGM PER ASCE 7-16,26.2 <br /> Exposure: B Wind Exposure Category as set forth in 2021 IBC,Section 1609.4 <br /> Wind Speed= 110 MPH Basic Wind Speed as used in ASCE 7-16,Figure 26.5-1(A-0) <br /> VAso= 86 MPH Allowable Stress Design Wind Speed _____'__.-..__._................................--..---.. <br /> ,k= 0.92 Adjustment factor for building height and exposure from Figure28.5-1 of ASCE 7-16 <br /> KZT= 1.37 Adjustment factor for increased wind speed due to a hill or escarpment <br /> rise run <br /> Front/Rear Slope=tan-1 ( Flat / 12 ) =0.0 degrees Number of floors: U <br /> Left/Right Slope=tan-1 1 12 ) = 18.4 degrees <br /> 22 R Mean Elevation per ASCE 7-16 26.2 <br /> Simplified Design Wind Pressure(Ps)=APs30Kzt ASCE 7-16,28.5.3 <br /> Average uplift(F!R)= -16.4 psf Based on wind zones'G'and'H' � <br /> Average uplift(R/L)= -17.6 psf Based on wind zones'G and'H' i <br /> � f1 <br /> End zone of wall End zone of roof j C <br /> Front/Rear Left/Right FrontfRear Left/Right ) <br /> PS30= A= 19.2 psf 25.8 psf B= -10.0 psf -7.3 psf j <br /> PS= 24.1 psf 32.5 psf 8.0 psf 80 psf <br /> MODIFIED AER M DIFIED PER w <br /> ASCE 7-16.28.5.4 ASCE 7-16,28.5.4 <br /> Interior zone of wall Interior zone of roof e U <br /> Front/Rear Left/Right Front/Rear Left/Right <br /> Ps30= C= 12.7 psf 17.2 psf D=-5.9 psf -4.1 psf <br /> PS= 16.0 psf 21.6 psf &0 psf 8.0 psf <br /> M DIFIED PER MODIFIED PER MODIFIED PER <br /> ASCE 7-16,28.5.4 1 ASCE 7-16 28.5A ASCE 7-16,28.5.4 Transverse <br /> FRONTIREAR ZONES <br /> EV Roof= <br /> WIND ZONE A C <br /> AVE.HEIGHT 3.5 3.5 <br /> AVE.WIDTH 6 38.7 <br /> Ps 24.14 16.00 0.00 0,00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 <br /> SUBTOTAL 507 2167 0 0 0 0 0 0 0 0 0 0 <br /> TOTAL t2,674lbs <br /> EV 2nd Floor = <br /> WIND ZONE A C <br /> AVE. HEIGHT 6 9 <br /> AVE.WIDTH 9 18 <br /> PS 24.14 16.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0,00 <br /> SUBTOTAL 1304 2592 0 0 0 0 0 0 0 0 0 0 <br /> TOTAL :3,896lbs <br /> £V Grade= <br /> WIND ZONE A C <br /> AVE.HEIGHT <br /> AVE.WIDTH <br /> Ps 24.14 16.00 0.00 0.00 0.00 0.00 0.00 0.00 0,00 0.00 0.00 0.00 <br /> SUBTOTAL 0 0 0 0 0 0 0 0 0 0 0 0 <br /> TOTAL :0lbs <br /> FV NA= <br /> WIND ZONE <br /> AVE.HEM-FI7 <br /> PS 0.00 0-00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 <br /> SUBTOTAL 0 0 0 0 0 0 0 0 0 0 0 0 <br /> TOTAL 101bs <br />