Laserfiche WebLink
. PASS A <br /> DATE: 11/10/2023 COMPANY: American Home Planners <br /> STRUCALC BUILD: StruCalc Plus DESIGNED BY: LV <br /> CUSTOMER- Levin REVIEWED BY: LV <br /> PROJ.ADDRESS: -- PROJECT NAME: Tyler Levin Revision Plan <br /> LEVEL- Main Floor LOADING: ASD <br /> MEMBER NAME: 6x6DF2Post@RearEndflrBm CODE: 2021 International Building Code <br /> MEMBER TYPE: COLUMN NDS: 2018 NDS <br /> MATERIAL- Solid Sawn <br /> Douglas Fir-Larch I No.2 (1)5.5 X 5.5 DRY <br /> EN-1 D •• X.N. <br /> 3in BL(A) BL(B) Sin <br /> 11111P41N] ••• <br /> Start(ft)0 End(ft):10 <br /> Area Ix ly SSW Lams G Kcr <br /> On') (in`) (In") (Ibf/ft) Creep Factor <br /> 30.25 76.25 76.25 6.9 1 0.5 1 <br /> Fb(psi) Ft(psi) Fv(psi) Fc(psi) Fc.L(psi) E(psi)x103 Emin(psi)X103 <br /> Base Values 750 475 170 700 625 1300 470 <br /> Adjusted Values 750 475 170 700 625 1300 470 <br /> CM 1 1 1 1 1 1 1 <br /> CT 1 1 1 1 1 1 1 <br /> Ci 1 1 1 1 1 1 1 <br /> CF 1 1 1 1 1 1 1 <br /> Bending Adjustment Factors C fu=1 Cr =1 <br /> Unbraced Length(ft) Column End <br /> Span Length(ft) X Y Offset CP Ke(X Axis) Ke(Y Axis) Kel./d(X Axis) Kel./d(Y Axis) <br /> 1 10 10 10 0 21.82 21.82 <br /> • ' PASS/FAIL MAGNITUDE STRENGTH LOCATION(ft) LOAD COMBO DURATION FACTOR CD <br /> Compressive Stress(psi) 268.3 485.5 0 D 0.9 <br /> • Units for V:Ibf Units for M:Ibf-ft <br /> Z axis DEAD TOTAL <br /> — A 8117 8117 ---- ---- — ----- ---- <br /> B 0 0 <br /> Reaction Location <br /> A B <br /> Type Name Left Magnitude Right Magnitude Load Start(ft) Load End(ft) Load Type Direction <br /> Axial pbf) Axial -8048 -8048 10 10 Dead Z <br /> Self Weight(Ibf/ft) 6.9 6.9 0 10 Dead Z <br /> PROJECT:Tyler Levin Revision Plan 2021 International Building Code ASD <br />