My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1013 RUCKER AVE 2025-08-20
>
Address Records
>
RUCKER AVE
>
1013
>
1013 RUCKER AVE 2025-08-20
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/20/2025 8:53:48 AM
Creation date
7/22/2025 10:02:32 AM
Metadata
Fields
Template:
Address Document
Street Name
RUCKER AVE
Street Number
1013
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
76
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Page 1 of 1 <br /> 11(razan & Associates, Inc. Field <br /> Geotechnical Engineering . Environmental Engineering Report NO.:09624498DFRO92024GM <br /> Construction Testing and Inspection <br /> DATE: 9/20/2024 Set Count: CONTRACTOR: Owner/Builder <br /> PROJECT#: 09624498 PERMIT#: B2308-026 <br /> PROJECT: Levin SFR INSPECTOR: G.Moe <br /> LOCATION: 1013 Rucker Avenue JURISDICTION: City of Everett <br /> KA P.M.: WEATHER: Fair, TEMP:70'F <br /> J <br /> m <br /> m <br /> As requested by Mr. Tyler Levin; <br /> Inspected the adhesive anchoring of 1" diameter threaded rods as required for the installation of Simpson <br /> Strong—Tie HDU 11 & HDU 14 Holdowns, inclusive. <br /> Threaded rods were installed using Simpson Strong—Tie SET—3G epoxy anchoring adhesive as per <br /> manufacturer's printed instructions, reference ICC Evaluation Services Report - 4057. <br /> Reviewed By: ASTM Test#: Asset Numbers : <br /> To the best of my knowledge,the above WAS performed in accordance with the approved plans, specifications and <br /> regulatory requirements. <br /> Superintendent/Representative: Technician: <br /> Offices Serving the Western United States <br /> Lynnwood(425)485-5519•Poulsbo(360)598-2126•Tacoma(253)939-2500 <br /> The information provided on this report is prepared for the exclusive use of the client.This report may not be reproduced in any format without the written permission of the client and Krazan&Associates.This report <br /> indicates our inspectors observation and testing results based on site conditions and contractor activities.This information is subject to review,prior to final submittal.By signing this report,our inspector does not accept <br /> responsibility for validity of results.The same information has been provided by others on site.The test results apply only to the specific locations,and items inspected or tested.Template date 12/8/2023 <br />
The URL can be used to link to this page
Your browser does not support the video tag.