Laserfiche WebLink
victaulic.com <br /> 6.0 NOTIFICATIONS <br /> A WARNING <br /> 9 0 A%MWk <br /> • Read and understand all instructions before attempting to install, remove, adjust, or maintain any Victaulic piping <br /> products. <br /> • Depressurize and drain the piping system before attempting to install, remove, adjust, or maintain any Victaulic <br /> piping products. <br /> • Wear safety glasses, hardhat, and foot protection. <br /> Failure to follow these instructions could result in death or serious personal injury and property damage. <br /> 7.0 REFERENCE MATERIALS <br /> Switch and Wiring <br /> 1. The supervisory switch contains two single pole, <br /> UL STED <br /> double throw, pre-wired switches. JUNCTION BOX <br /> NC <br /> 2. Switches are rated: CONDUIT <br /> L <br /> 10 amps @ 125 or 250 VAC/60 Hz <br /> 0.50 amps @ 125 VDC / NPCONDUR CONNECTORS <br /> 0.25 amps @ 250 VDC <br /> WIRE NUTS <br /> 3. Switches supervise the valve in the "OPEN" position. <br /> 5. One switch has two#18 insulated wires per terminal, FIRE ALARMWOR <br /> OF-LINE RESISTOR, <br /> which permit complete supervision of leads (refer CONTROL PANELEXT INDICATOR <br /> SUPERVISORY <br /> to diagrams and notes below). The second switch CIRCUIT <br /> has one #18 insulated wire per terminal. This double SWfTCHcircuit provides flexibility to operate two electrical COINTACT RATING10A AT125 ANDdevices at separate locations, such as an indicating 250VAC, <br /> O.SA AT125 VDC, <br /> light and an audible alarm, in the area that the valve 0.25 AT 250 VDCIFI I <br /> is installed. 1JF. <br /> VOLTAGE SOURCE FI1111 <br /> 6. A#14 insulated ground lead (green) is provided. <br /> Switch 1:2leads per terminal <br /> Switch #1 = S1 Switch 2:1 lead per terminal <br /> For connection to the supervisory circuit of a UL <br /> Listed alarm control panel NOTES <br /> • The above diagram shows a connection between the common terminal <br /> Switch #2 = S2 (yellow—S1 and yellow-with-orange stripe—S2)and the normally closed <br /> Auxiliary switch that may be connected to auxiliary terminal(blue—S1 and blue-with-orange stripe—S2).In this example, <br /> y y y the indicator light and alarm will stay on until the valve is fully open.When <br /> devices, per the authority having jurisdiction the valve is fully open,the indicator light and alarm will go out.Cap off <br /> any unused wires(e.g.brown with orange stripe). <br /> Normally Closed: (2) Blue • Only S1(two leads per terminal)may be connected to the fire alarm <br /> Sl control panel. <br /> Common: (2) Yellow • The connection of the alarm switch wiring shall be in accordance with <br /> NFPA 72 and the auxiliary switch per NFPA 70(NEC). <br /> Normally Closed: Blue with Orange Stripe <br /> S2 Normally Open: Brown with Orange Stripe <br /> Common: Yellow with Orange Stripe <br /> 10.81 05662 Rev J Updated 03/2021 ©2021 Victaulic Company.All rights reserved. <br /> victaulic.com 6 ✓ctaulic° <br />