May 28, 2010 Sprinker 13g <br /> STANDARD RESPONSE <br /> ELO UPRIGHT AND <br /> PENDENT SPRINKLERS I I a:N:G:*: (STORAGE-DENSITY/AREA) <br /> The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 <br /> Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com <br /> TABLE 1:AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES <br /> Sprinkler Temperature Sprinkler Nominal Maximum Ambient Bulb Color <br /> Classification Temperature Rating' Ceiling Temperature <br /> Ordinary 155 °F (68 °C) 100 °F (38 °C) Red <br /> Intermediate 175 °F (79 °C) 150 °F (65 °C) Yellow <br /> Intermediate 200 °F (93 °C) 150 °F (65 °C) Green <br /> High 286 °F (141 °C) 225 °F (107 °C) Blue <br /> Sprinkler Finishes: Brass, Chrome-Enloy®, White Polyester, Black Polyester, and Black Teflon° <br /> Corrosion-Resistant Coatings3: White Polyester, Black Polyester, and Black Teflon°in all temperature ratings. Wax-Coated Brass for <br /> sprinklers with the following temperature ratings: <br /> 155 °F (68 °C) Lt. Brown Wax 175 °F (79 °C) Brown Wax 200 °F (93 °C) Brown Wax 286 °F (141 °C) Dk. Brown Wax4 <br /> Footnotes <br /> The sprinkler temperature rating is stamped on the deflector. <br /> 2 Based on NFPA-13.Other limits may apply,depending on fire loading,sprinkler location,and other requirements of the Authority Having Jurisdiction. <br /> Refer to specific installation standards. <br /> s The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts.These <br /> tests cannot and do not represent all possible corrosive environments. Prior to installation,verify through the end-user that the coatings are compat- <br /> ible with or suitable for the proposed environment. For automatic sprinklers,the coatings indicated are applied to the exposed exterior surfaces only. <br /> Note that the spring is exposed on sprinklers with Polyester and Teflon®coatings. For Teflon®coated open sprinklers only,the waterway is coated. <br /> 4 Wax melting point is 170°F(76°C)for 286°F(141 °C)temperature rated sprinklers. <br /> I I <br /> WIN im <br /> I I <br /> NEWIVISHI . <br /> 0 0 <br /> Sprinkler Wrench <br /> 11663W/B)K)K must be <br /> used for installing <br /> recessed Sprinkler VK536 <br /> Step 1: Carefully slide I <br /> the wrench sideways i — j <br /> around the deflector _--_ --------____ <br /> and protective shield. <br /> )KA 1/2' ratchet is required ------- Step 2: Carefully press the <br /> (Note the orientation of (not available from Viking), wrench upward and turn slightly <br /> the shield in the wrench.) to ensure engagement with <br /> the sprinkler wrench flats. <br /> Figure 2: Wrench 11663W/B for Coated and/or Recessed Pendent ELO Sprinklers <br />