CO® Worldwide www.tyco-fire.com <br /> Contacts <br /> Model DPV4 Dry Pipe Valve <br /> External Resetting <br /> General <br /> Description <br /> The TYCO Model DPV-1 Dry Pipe <br /> Valves are differential valves used to <br /> automatically control the flow of water <br /> into dry pipe fire protection sprinkler <br /> systems upon operation of one or more I <br /> automatic sprinklers. The DPV-1 also <br /> provides for actuation of fire alarms r: <br /> upon system operation. The Model <br /> DPV-1 features are as follows: <br /> • External reset. <br /> • 250 psi (17,2 bar) pressure rating. <br /> • Unique offset single clapper design <br /> enabling a simple compact valve to <br /> minimize installation labor. <br /> • Ductile iron construction to ensure Available Sizes and End Connections <br /> a lightweight valve to minimize ship- <br /> ping cost. Nominal Valve Size <br /> • A variety of inlet and outlet End Connection 2-1/2 in. 3 in. 4 in. 6 in. <br /> connections. (DN65) (DN80) (DN100) (DN150) <br /> • Compact, Pre-Trimmed, and Semi- Flange x Flange N/A N/A • <br /> Assembled, easy to operate valve Flange x Groove N/A N/A • <br /> trim. Groove x Groove • <br /> • Simple reset procedure through the .-Available <br /> elimination of priming water. N/A-Not Available <br /> Dry pipe sprinkler systems are used <br /> in unheated warehouses, parking INOTRIM Dry Pipe Valve <br /> garages, store windows, attic The Model DPV-1 Dry Pipe Valves The TYCO Model DPV-1 Dry Pipe <br /> spaces, loading docks, and other described herein must be installed Valves shall be installed in the verti- <br /> areas exposed to freezing tempera- and maintained in compliance with cal orientation only (supply at bottom <br /> tures, where water filled pipe cannot this document, as well as with the flowing upward)and are rated for use at <br /> be utilized. When set for service, the applicable standards of the National a maximum service pressure of 250 psi <br /> dry pipe sprinkler system is pressur- Fire Protection Association, in addition (17,2 bar). Valve and trim dimensions <br /> ized with air (or nitrogen). The loss of to the standards of any other authori- are shown in Figure 6. <br /> pressure through an operated auto- ties having jurisdiction. Failure to do so Flanged connections are available and <br /> matic sprinkler in response to heat may impair the performance of these drilled per ANSI,ISO,AS,and JIS spec- <br /> from a fire permits the DPV-1 Dry devices. ifications (Ref. Table A). The grooved <br /> Pipe Valve to open and allow a flow of outlet connections, as applicable, are <br /> water into the sprinkler system piping. The owner is responsible for main- cut in accordance with standard groove <br /> Table B establishes the minimum taining their fire protection system specifications for steel pipe. They are <br /> required system air pressure that and devices in proper operating con- suitable for use with grooved end pipe <br /> includes a safety factor to help prevent dition. Contact the installing contrac- couplings that are listed or approved <br /> false operations that might occur due for or product manufacturer with any for fire protection system service. <br /> to water supply fluctuations. questions. <br /> Available combinations of inlet and <br /> outlet connections are described in <br /> Technical Data the Ordering Procedure section and in <br /> IMPORTANT the Available End Connection and Sizes <br /> Refer to Technical Data Sheet Approvals table on page 1. <br /> TFP2300 for warnings pertaining to UL and C-UL Listed <br /> regulatory and health information. <br /> FM Approved Trim port connections of valves having <br /> NYC Approved flanges drilled to ANSI,AS,or JIS spec- <br /> Page 1 of 20 OCTOBER 2018 TFP1020 <br />