My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD BLDG 40-87 2025-08-21
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-87
>
3003 W CASINO RD BLDG 40-87 2025-08-21
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/21/2025 10:49:36 AM
Creation date
7/23/2025 9:15:10 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-87
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
257
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
TFP1O2O <br /> Page 7 of 20 <br /> Valve Setting Step 5.As necessary,replace all sprin- to the Care and Maintenance section <br /> klers that have operated. Replacement under Automatic Drain Valve Inspection <br /> Procedure sprinklers must be of the same type to determine/correct the cause of the <br /> and temperature rating as those which leakage problem. <br /> Steps 1 through 11 are to be performed have operated. Step 10. Partially open the Main <br /> when initially setting the Model DPV-1 Control Valve. Slowly close the Main <br /> Dry Pipe Valve;after an operational test MUM Drain Valve as soon as water dis- <br /> of the fire protection system; or, after In order to prevent the possibility of charges from the drain connection. <br /> system operation due to a fire. a subsequent operation of an over- Depress the plunger on the Automatic <br /> NOTES:If the DPV-1 is equipped with heated solder type sprinkler,any solder Drain Valve to make sure that it is open <br /> a Dry Pipe Valve Accelerator, refer to type sprinklers which were possibly and that there is no water discharging. <br /> its resetting instructions before reset- exposed to a temperature greater than The absence of water discharging from <br /> ting the DPV-1.Refer to TFP1105 for the their maximum rated ambient must be the Automatic Drain Valve is an indica- <br /> VIZOR or TFP1112 for the ACC-1. replaced. tion of a properly set water seat within <br /> Based on the instructions provided, Step 6. Push down on the Reset Knob the DPV-1 Valve. If water is discharg- <br /> reset the Accelerator at the appropriate (Figure 2E)to allow the Clapper Assem- ing, refer to the Care and Maintenance <br /> time during the resetting of the DPV-1. bly to re-seat. section under the Automatic Drain <br /> Step 7. Pressurize the system with air Valve Inspection to determine/correct <br /> Unless otherwise noted,refer to Figure 3, 4, or 5 to identify functional trim (or nitrogen) to 10 psi (0,7 bar), and the cause of the leakage problem. <br /> components. then individually open all auxiliary drain If there are no leaks,the DPV-1 Valve is <br /> valves in the system piping to drain ready to be placed in service and the <br /> Step 1. Close the Main Control Valve, any remaining water in trapped sec- Main Control Valve must then be fully <br /> and close the Air Supply Control Valve. tions. Close each drain valve as soon opened. <br /> If the DPV-1 is equipped with a Dry as water ceases to discharge. Note: After setting a fire protection <br /> Pipe Valve Accelerator, remove the Dry <br /> Pipe Valve Accelerator from service in Also partially open the Low Body Drain system, notify the proper authorities <br /> accordance with its Technical Data Valve to assure that the riser is com- and advise those responsible for moni- <br /> S heet(Refer to TFP1105 for the VIZOR pletely drained. Close the Low Body toring proprietary and/or central station <br /> or TFP1112 for the ACC-1). Drain Valve as soon as water ceases alarms. <br /> Step 2.Open the Main Drain Valve and to discharge. Step 11. Once a week after a valve is <br /> all auxiliary drains in the system.Close Step 8. Refer to Table B and then reset following an operational test or <br /> the auxiliary drain valves after water restore the system to the normal system operation,the Low Body Drain <br /> ceases to discharge. Leave the Main system air pressure as necessary to Valve (and any low point drain valves) <br /> Drain Valve open. hold the DPV-1 Valve closed. should be partially opened (and then <br /> Step 9. Depress the plunger on the subsequently closed) to relieve drain- <br /> Step Depress the plunger the Automatic Drain Valve to make sure back water. Continue this procedure <br /> drain- <br /> Automatic tic Drain Valve to verify that it is until drain-back water is no longer it is open and that there is no air <br /> open and that the DPV-1 Valve is com-pletely drained. discharging. present. <br /> Step 4. Open the Optional Alarm The absence of air discharging from <br /> Control Valve, as applicable, if it was the Automatic Drain Valve is an indica- <br /> closed to silence local alarms. tion of a properly set air seat within the <br /> DPV-1 Valve. If air is discharging, refer <br />
The URL can be used to link to this page
Your browser does not support the video tag.