Laserfiche WebLink
(E) POTTER AFC-1 00 <br /> The Symbol of Protection Fire Alarm Control Panel <br /> SLC Loop Accessories <br /> The control panel may be connected with up to 100 addressable devices or modules in any combination.The SLC is not restricted by any special wire <br /> requirements and may be wired with any wire that complies with the NEC. <br /> SLC Loop Devices <br /> Device Description <br /> PAD Series-PD Analog Photoelectric Smoke Detector is a smoke detector with a listed obscuration of 1.1 to 3.5%/foot.UL 268 7th Edition. <br /> Combination Analog Photoelectric Smoke/Heat Detector—a smoke detector with a listed obscuration of 1.1 to 3.5%/foot <br /> PAD Series-PHD obscuration and a fixed temperature range of 135'to 185'F heat detector.Smoke detection compliant with UL 268 7th <br /> Edition. <br /> PAD Series-PCD Combination Photoelectric Smoke/Carbon Monoxide Detector.Smoke detection compliant with UL 268 7th Edition.Carbon <br /> Monoxide detection compliant with UL 2075. <br /> Combination Photoelectric Smoke/Heat/Carbon Monoxide Detector.Smoke detection compliant with UL 268 7th Edition.Heat <br /> PAD200-PCHD detection with a fixed temperature range of 135'to 185'F and UL 521 7th Edition compliant.Carbon Monoxide detection <br /> compliant with UL 2075. <br /> PAD Series-HD Analog Fixed Temperature(135'- 185°F)or Rate-of-Rise Heat Detector(software selectable). <br /> PAD Series-DUCTR Addressable Duct Smoke Detector with Form C Relay rate at IOAmps @ 250/120VAC or 8 Amps at 30VDC. <br /> PAD Series-DUCT Addressable Duct Smoke Detector. <br /> PAD100-6DB 6"round base that is mountable to an electrical box and wired for connection to the PAD100/200 devices. <br /> PAD 100-4DB 4"round base that may be mounted to an electrical box and wired for connection to the PAD 100/200 devices. <br /> PAD 100-IB Isolator base that interrupts a short in a SLC and prevents the short from affecting protected devices on the loop and used for <br /> connection to the PAD100/200 devices. <br /> PAD 100-RB Addressable Relay Base that contains one relay controlled by the SLC.Relay at rated at 2 amps at 30 VDC or 0.5A at <br /> 125VAC.For PAD100/200 devices only. <br /> PAD 100-SB Addressable Sounder Base that contains an addressable sounder module which allows for configuration of local,group,and/ <br /> or all call.For PAD100/200 devices only. <br /> PAD Series-CD Addressable CO gas detector. <br /> PAD200-DD Addressable photoelectric smoke detector for use in DUCT/DUCTR enclosure. <br /> PAD300-DD Addressable photoelectric smoke detector for use in DUCT/DUCTR enclosure or pendant mount applications. <br /> Addressable Low Frequency Sounder Base that contains an addressable sounder module which allows for configuration <br /> PAD100-LFSB of local,group,and/or all call.The LFSB complies with the Low Frequency Signal Requirements(520 Hz)and used for <br /> connection to the PAD100/200 devices. <br /> PAD100-SPKB Speaker base is a wall or ceiling mount speaker capable of 25 or 70.7 VRMS and is field selectable from 1/8W to 4W and <br /> used for connection with the PAD100/200 devices. <br /> PAD300-6DB 6"round base which is mountable to an electrical box and wired for connection to the PAD300 devices. <br /> PAD300-4DB 4"round base which is mountable to an electrical box and wired for connection to the to the PAD300 devices. <br /> PAD300-IB Isolator base that interrupts a short in a SLC and prevents the short from affecting protected devices on the loop.Used for <br /> connection to the PAD300 devices. <br /> PAD300-RB Addressable Relay Base that contains one relay controlled by the SLC.The Relay is rated 2 amps at 30 VDC or 0.5A at <br /> 125 VAC and used for connection to the PAD300 devices <br /> PAD300-SB Addressable Sounder Base that contains an addressable sounder module which allows for configuration of local,group,and/or <br /> all call;and used for connection to the PAD300 devices. <br /> Addressable Low Frequency Sounder Base that contains an addressable sounder module which allows for configuration <br /> PAD300-LFSB of local,group,and/or all call.The LFSB complies with the Low Frequency Signal Requirements(520 Hz)and used for a <br /> connection to the PAD300 devices. <br /> Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com <br /> 8830134-REV G 5/23 PAGE 2 OF 5 <br />