Laserfiche WebLink
Page 3 of 6 <br /> C QUICK RESPONSE <br /> HORIZONTAL SIDEWALL <br /> SPRINKLER VK360 (K8.0) <br /> _N41KjW4j <br /> The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 <br /> Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com <br /> Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com <br /> TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES <br /> Sprinkler Temperature Sprinkler Nominal Maximum Ambient Bulb Color <br /> Classification Temperature Rating' Ceiling Temperature2 <br /> Ordinary 135 °F (57 °C) 100 °F (38 °C) I Orange <br /> Ordinary 155 °F (68 °C) 100 °F (38 °C) Red <br /> Intermediate 175 °F (79 °C) 150 °F (65 °C) Yellow <br /> Intermediate 200 °F (93 °C) 150 °F (65 °C) Green <br /> Sprinkler Finishes: Brass, Chrome, White Polyestei Black Polyester3,4, and ENTs,a,e <br /> Corrosion Resistant Sprinkler Coatings: White Polyestei Black Polyestei and ENTs,a,e <br /> Footnotes <br /> The sprinkler temperature rating is stamped on the deflector. <br /> Z Based on NFPA-13.Other limits may apply,depending on fire loading,sprinkler location,and other requirements of the Authority Having Jurisdiction. <br /> Refer to specific installation standards. <br /> 3 The corrosion-resistant coatings have passed the standard corrosion tests required by the approving agencies as indicated in the Approval Chart. <br /> These tests cannot and do not represent all possible corrosive environments. Prior to installation,verify through the end-user that the coatings are <br /> compatible with or suitable for the proposed environment. For automatic sprinklers,the coatings indicated are applied to the exposed exterior sur- <br /> faces only. For ENT automatic sprinklers,the waterway is coated. Note that the spring is exposed on sprinklers with Polyester and ENT coatings. <br /> 4 clJLus Listed as corrosion resistant. <br /> s ENT finish is not available in 135°F(57°C). <br /> Sprinkler Wrench Part No, 13655W/B)K <br /> dust be used with Coated and/or <br /> Recessed Sprinkler VK360. <br /> (Recessed Sprinkler VK360 is shown,) <br /> Fit the wrench over the sprinkler <br /> and protective shield as shown. <br /> Protective <br /> (Note the orientation of Sprinkler <br /> the shield in the wrench.) Shield <br /> I <br /> --F- o <br /> i <br /> I I I I <br /> -+-+---------- --------I I III I -- - ----- --- ---- <br /> \ —�— �Ij ylj Jlj yi <br /> I <br /> )KNote: A 1/2' ratchet <br /> is required (not <br /> available from Viking), <br /> Figure 2: Installation of Coated and/or Recessed Sprinkler VK360 <br /> Form No. F_092508 20.06.04 Rev 20.1 <br />