Laserfiche WebLink
Page 5 of 6 <br /> ® QUICK RESPONSE <br /> NIKJNG4 HORIZONTAL SIDEWALL <br /> SPRINKLER VK360 (K8.0) <br /> The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 <br /> Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email:techsvcs@vikingcorp.com <br /> Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com <br /> DESIGN CRITERIA <br /> (Also refer to the Approval Chart) <br /> cULus Listing Requirements: <br /> Quick Response Horizontal Sprinkler VK360 is cULus Listed as indicated in the Approval Chart for installation in accordance with the latest edition of <br /> NFPA 13 for sidewall standard spray sprinklers. <br /> • Designed for use in Light and Ordinary Hazard occupancies. <br /> • Locate the deflector 4"to 12"(102 mm to 305 mm)below the ceiling. <br /> • Protection areas and maximum spacing shall be in accordance with the tables provided in NFPA 13. <br /> • Minimum spacing allowed is 6 ft. (1.8 m). <br /> • Locate no less than 4"(102 mm)from end walls. <br /> • Maximum distance from end walls shall be no more than one-half of the allowable distance between sprinklers.The distance shall be measured <br /> perpendicular to the wall. <br /> • The sprinkler installation and obstruction rules contained in NFPA 13 for sidewall standard spray sprinklers must be followed. <br /> DEFLECTOR POSITION: Install sprinkler VK360 with the leading edge of the deflector and the sprinkler frame arms oriented parallel to the ceiling(see <br /> Figure 3).THE TOP SURFACE OF THE DEFLECTOR IS MARKED"TOP".The sprinkler must be oriented as shown in Figure 3. <br /> IMPORTANT:Always refer to Bulletin Form No. F_091699-Care and Handling of Sprinklers.Also refer to Form No. F_080614 <br /> for general care, installation, and maintenance information.Viking sprinklers are to be installed in accordance with the latest <br /> edition of Viking technical data,the appropriate standards of NFPA, FM Global, LPCB,APSAD,VdS or other similar organiza- <br /> tions, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. <br /> Wall Opening Size: <br /> 2-5/16' (58.7 mm) minimum <br /> 2-1/2' (63.5 mm) maximum <br /> 2-1/2' <br /> 2-5/8" (63,5 mm) <br /> (66 mm) <br /> m w <br /> 3/4" T <br /> (20 mm) Sprinkler VK360 <br /> NPT <br /> Installed with a <br /> standard 1/8' (3.1 mm) <br /> surface-mounted escutcheon, <br /> Figure 4: Sidewall Sprinkler VK360 Dimensions with a Standard Escutcheon <br /> Form No. F_092508 20.06.04 Rev 20.1 <br />