Model W2 (non-recessed) Model W4 <br /> (recessed,concealed pendent) <br /> Finishes0) . • - <br /> Standard Finishes Special Application Finishes <br /> Sprinkler F1,F2 and FPM CCP Cover Sprinkler F1, F2 and FP(2) CCP Cover Plate(2) <br /> Escutcheons Plate(2) Escutcheons <br /> Bronze Brass Chrome Electroless Nickel PTFE(3)(4) Bright Brass Bright Brass <br /> Chrome Chrome White Paint Bright Brass Satin Chrome Satin Chrome <br /> White Polyester(3) White Polyester Satin Chrome Custom Color Polyester Custom Color Paint <br /> Custom Color Polyester(3) <br /> Notes: <br /> 1. Paint or any other coating applied over the factory finish will void all approvals and warranties. <br /> 2. Model FP escutcheons and Model CCP sprinklers utilize a galvanized steel cup with a finished trim ring or cover plate. <br /> 3. cULus Listed as corrosion resistant. <br /> 4. FM Approved as corrosion resistant(horizontal sidewall only). <br /> Installation Maintenance <br /> Model F1 FR EC Series sprinklers must be installed in accordance Reliable Model F1 FIR EC series sprinklers should be inspected <br /> with NFPA13 and the requirements of all applicable authorities and the sprinkler system maintained in accordance with NFPA <br /> having jurisdiction using the Reliable sprinkler installation wrench 25, as well as the requirements of any Authorities Having <br /> identified in this bulletin.Any other wrench may damage the Jurisdiction. <br /> sprinkler. The Models W2 and W4 wrenches have two sets of Prior to installation, sprinklers should remain in the original <br /> jaws. Use the smallest set of jaws that fit on the wrench flats of cartons and packaging until used.This will minimize the potential <br /> the sprinkler. A leak tight sprinkler joint can be obtained with a for damage to sprinklers that could cause improper operation or <br /> torque of 8 to 18 lb-ft(11 to 24 N•m). Do not tighten sprinklers over non-operation. <br /> the maximum recommended installation torque. Exceeding the <br /> maximum recommended installation torque may cause leakage or Do not clean sprinklers with soap and water, ammonia liquid or <br /> impairment of the sprinkler. any other cleaning fluids. Remove dust by gentle vacuuming <br /> without touching the sprinkler. <br /> Glass bulb sprinklers have orange bulb protectors or protective Replace any sprinkler which has been painted (other than factory <br /> caps to minimize bulb damage during shipping, handling and applied).A stock of spare sprinklers should be maintained to <br /> installation. Reliable sprinkler installation wrenches are designed allow quick replacement of damaged or operated sprinklers. <br /> to install sprinklers with bulb protectors in place. Remove the bulb Failure to properly maintain sprinklers may result in inadvertent <br /> protector at the time when the sprinkler system is placed in service operation or non-operation during a fire event. <br /> for fire protection. Removal of the bulb protector before this time <br /> may leave the bulb vulnerable to damage. Remove bulb protectors <br /> by undoing the clasp by hand. Do not use tools to remove bulb <br /> protectors. <br /> Bulletin 028 Reliable Page 6 of 7 <br /> October 2022 www.reliablesprinkler.com <br />