Laserfiche WebLink
■ - ■ • AA4V Star <br /> Fire Products Division of Anvil'International <br /> SPF/RNVIL" Ductile Iron Submittal Sheet <br /> 1 <br /> REDUCING <br /> 0' ELBOW <br /> Nominal Anvil Item Universal Max- Dimensions Approx. <br /> Size Number Number Working Wt.Each <br /> Pressure A B <br /> In.(mm) PSI(kPa) In.(mm) In.(mm) Lbs.(kg) <br /> 1 x 1/2 840001036 DB90031 500 1.26 1.36 0.44 <br /> F B 25 x 15 3450 32.00 34.54 0.20 <br /> 1 x 3/4 840001044 DB90032 500 1.37 1.45 0.52 <br /> 25 x 20 3450 34.79 36.83 0.24 <br /> 11/4xt/2 840001051 DB90041 500 1.34 1.53 0.64 <br /> 32 x 15 34550 34.03 38.86 0.29 <br /> A I 11/4 X 3/4 840001069 DB90042 500 1.45 1.62 0.72 <br /> 32 x 20 3450 36.83 41.14 0.33 <br /> 11/4 x 1 840001077 DB90043 500 1.58 1.67 0.75 <br /> 32 x 25 3450 40.13 42.41 0.34 <br /> 11/2 x 1 840001085 DB90053 500 1.65 1.80 0.92 <br /> 40 x 25 3450 41.91 45.72 0.42 <br /> 11h x 1'A 840001093 DB90054 500 1.82 1.88 1.08 <br /> 40 x 32 3450 46.22 47.75 0.49 <br /> 2 x 1/2 840001101 DB90061 500 1.49 1.88 1.08 <br /> 50 x 15 3450 37.84 47.75 0.49 <br /> 2 x 3/4 840001119 DB90062 500 1.60 1.97 1.24 <br /> 50 x 20 3450 40.64 50.03 0.56 <br /> 2 x l 840001127 DB90063 500 1.73 2.02 1.40 <br /> 50 x 25 3450 43.94 51.30 0.64 <br /> 2 x 11/4 840001135 DB90064 500 1.90 2.10 1.52 <br /> 50 x 32 1 3450 48.26 53.34 0.70 <br /> 2 x11/2 840001143 DB90065 1 500 2.02 2.16 1.65 <br /> 50 x 40 3450 1 51.30 54.86 0.75 <br /> MATERIAL SPECIFICATIONS <br /> Ductile iron threaded fittings are UL & ULC Listed & Dimensions conform to ASME B16.3 Class 150. UL LC <br /> Factory Mutual Approved for 500 psi service. Threads are NPT per ANSI/ASME B1 .20.1. 1M <br /> Ductile iron per ASTM A536 Class 65-45-12. For Listing sting/AD <br /> Approval <br /> NOTICE:Ductile iron Fittings have higher tensile strength than that of steel pipe.Therefore,over tightening can cause damage to a threads which may cause leakage.Ductile details contact your <br /> g g g p t g g g pipe y g AnvilStarTm Representative. <br /> iron fittings should be tightened three turns beyond hand tight,but no more than four turns. <br /> PROJECTr rAPPROVAL <br /> Project: <br /> Date: Phone: <br /> Architect/Engineer: <br /> Contractor: <br /> Address: <br /> Notes 1: <br /> Notes 2: <br /> SPF Cast & Ductile Iron Fittings For the latest UL/ULC Listed and FM Approved pressure ratings,versus pipe schedule, J&W'L <br /> REV.03.03.06-0012 go to www.anvilstar.com or contact your local AnvilStar representative �l <br />