My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1215 80TH ST SW 2022 Plans 2025-08-07 (2)
>
Address Records
>
80TH ST SW
>
1215
>
Plans
>
1215 80TH ST SW 2022 Plans 2025-08-07 (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/24/2025 9:27:18 AM
Creation date
7/24/2025 9:26:06 AM
Metadata
Fields
Template:
Address Document
Street Name
80TH ST SW
Street Number
1215
Permit
PW2203-018
Year
2022
Notes
SITEWORK FOR NEW 166,590 SF WAREHOUSE INDUSTRIAL BLDG
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
28
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
WATERMAIN EXTENSION PLAN <br /> nSEC.12 SW,TOWNSHIP 28 N., RANGE 4 E. W.M. <br /> Know what's below. FLU <br /> Call before you dig. <br /> o LU <br /> 2 U U S U <br /> Gl 2 Z lf) <br /> NOTES PARTS z && J V <br /> 0 0 <br /> A. ROMAC,FORD OR MUELLER DOUBLE STRAP SERVICE SADDLE WITH I.P.THREAD TO BE USED ON ALL MAINS 4"DIA A. HYDRANTS AND ALL MATERIALS SHALL CONFORM TO65 <br /> AND LARGER.ALL NEW TAPS ON EXISTING WATER MAINS SHALL BE DONE BY THE CITY OF EVERETT UTILITIES AWWA STANDARDS AND SHALL BE OF STANDARD z <br /> DEPARTMENT AT TH E DEVELOPERS OR CONTRACTORS EXPENSE. MANUFACTURE(MUELLER SUPER CENTURION#250, �z z Zi Zi i W <br /> B. 2"BRASS NIPPLE. WATEROUS PACER#WB67,OR CITY APPROVED U U N N Q Q O O <br /> C. HEAVY DUTY 2"GATE VALVE WITH RESILIENT SEAT AND 2"OPERATING NUT.GATE VALVES SHALL BE"WATEROUS" EQUAL). ¢ a z.¢m <br /> SERIES 2500 OR CITY APPROVED EQUAL. <br /> D. MUELLER H-15451N OR H-15428N OR APPROVED EQUAL.USE APPROPRIATE STAINLESS STEEL INSERT STIFFENER B. 5-1/4"VALVE MINIMUM. w o c w w <br /> WITH POLYETHYLENE TUBING.PHYSICAL BENDS IN POLY PIPE ARE NOT ALLOWED,USE BRASS ELBOWS. W LL.I <br /> C. 1-1/4"OPERATING NUT AND CAP NUT FOR 2-1/2" <br /> K E. RESIDENTIAL SERVICE MAX RAKE,1/4"PER FT PORTS. N <br /> 1.PROVIDE 2"POLYETHYLENE TUBING MEETING THE FOLLOWING REQUIREMENTS: B <br /> a.AWWA C901. FROM GROUND LEVEL n <br /> D. NATIONAL STANDARD THREAD ON 2-1/2"PORTS. i .0000. Ir <br /> m LU <br /> b.ASTM D2737,SIDR 9(pe3608/4710). a <br /> c.ASTM 3350-PE3608 OR PE4710. E. 5"STORZ FITTING WITH NATIONAL STANDARD THREAD Q <br /> z ON THE 4-1/2"PORT. S S S S 2.PROVIDE A#10 AWG,SINGLE STRAND COPPER WIRE WITH BLUE TYPE OF OR USE COATING SUITABLE FOR I m m � to <br /> > DIRECT BURY. C F. IF HYDRANT RISES THROUGH CONCRETE,USE w Jn <br /> L J o a.WRAP WIRE AROUND TUBING,ONE WRAPPER FT,ITS ENTIRE LENGTH. E s o 0 0 0 <br /> �+ EXPANSION STRIP AROUND HYDRANT BARREL,PER STD m <br /> z b.SECURE ONE END AROUND THE SADDLE BOLT BETWEEN TWO NUTS AND EXPOSE MINIMUM OF 18" PLAN 509.IN ADDITION,INSTALLATION OF THE <br /> A o OF THE OTHER END IN THE METER BOX. HYDRANT ON PRIVATE PROPERTY SHALL EQUAL OR <br /> U EXCEED THE STANDARDS FOR INSTALLATION OF \ \ \\\ <br /> z BALL F NON-RESIDENTIAL SERVICE TRAFFIC SAFETY PUBLIC FIRE HYDRANTS IN THE CITY OF EVERETT. N a y m m N $ <br /> H VALVE 1.PROVIDE 2"TYPE K COPPER TUBING MEETING ASTM 888,ANSI/NSF 61&APPLICABLE IAPMO STANDARDS. I FEATURE BREAK-OFF VALVE BOX AND EXTENSION PER <br /> - STANDARD DRAWING 505 <br /> FLANGE,BREAK OFF G. PROVIDE FOR VEHICULAR TRAFFIC PROTECTION WHEN <br /> G. BRASS ELBOWS&NIPPLESAS NEEDED. NUTSAND BOLTS NECESSARY PER STANDARD DRAWING 508. m v,O M N <br /> CHECK H. METER SETTERS SHALL BE"FORD"70 SERIES COPPER SETTER VBH77-12B-11-77 WITH HORIZONTAL INLET AND <br /> O D VALVE W OUTLET APPROVED HALL BE H. STEAMERPOR TO BE FACING STREET OR ROADWAY <br /> \ \�// ���%\% T <br /> I. METER SHALL BE SUPPLIED AND INSTALLED BY CITY UTILITIES DEPARTMENT AT THE DEVELOPERS OR CONTRACTORS � FOR FIRE ENGINE ACCESS. <br /> EXPENSE. <br /> J. PROVIDE METER BOX BODY MANUFACTURED BY"RAVEN PRODUCTS,MODEL RMB-17-30-12",MOUSEHOLES CUT, 1/2 CU YD WASHED ROCK F 1 I. BREAK-OFF FLANGE TO BE 2"-4"ABOVE GROUND <br /> D G <br /> WITH AASTH0 H-20 RATED DUCTILE IRON FLUSH SOLID COVER LID OR EQUAL. 1-1/2"DRAIN ROCK <br /> G m > DUCTILE IRON TEE LEVEL. LO <br /> K. PIACE SAWDUST IN METER BOX AROUND PIPE TO TOP OF METER TO PREVENT FREEZING. } <br /> F RETAINER (M1xM1xFL)OR <br /> L. ADJUSTABLE VALVE BOX AND EXTENSION SEE STD 505. \\ GLANDS TAPPING TEE(FL) J. INSTALLCONCRETE PAD AROUND HYDRANT IN W <br /> UNPAVED,SOD AND ASPHALT AREAS PER STANDARD <br /> B C G D E \% \ DRAWING 508. W <br /> K. HYDRANT CONNECTION PIPE TO BE DUCTILE IRON ~ O T <br /> CLASS 52,ANY INTERMEDIATE JOINTS TO BE MI WITH 0 1 <br /> \\\ \ RETAINER GLANDS,OR FIELD LOCK GASKETS. O co <br /> 2 2 \%�� \\ L. FIRE HYDRANTS SHALL BE PAINTED WITH TWO COATS K �R <br /> 2"METEREDWATERSERVICE OF HIGH GLOSS CATERPILLAR YELLOW,LUXUTE V W Q N <br /> #6100-516 OR 12"x 12"x4" EQUAL.THE PORT CAPS WILLBE PAINTED BLACK. Z � m <br /> CONC BLOCK GATE VALVE <br /> x x (MJx FL) M.PROVIDE FOR AMINIMUM OF 3'CLEAR ZONE AROUND W <br /> 0 ` <br /> 0 0 6 MIL PLASTIC SHEETING WRAP HYDRANT. Z N <br /> n n UNDISTURBED EARTH Q T C '` <br /> CITY OF EVERETT o CITY OF EVERETT <br /> LIW 2 v� <br /> PUBLIC WORKS DEPARTMENT PUBLIC WORKS DEPARTMENT (Q '�. LL Z <br /> 101M.— __1RB w &rnx w.'m"'^ 101M.— <br /> � 03�06�2017 �� Sf9�2018 O <br /> METERED WATER SERVICES "�eetiww. FIRE HYDRANT E5O <br /> NU <br /> 2" 502 !s> INSTALLATION oD <br /> NOTES NOTES PARTS <br /> 1. STAINLESS STEELTAPPING SLEEVES SHALL HAVE 1. TEE AND GATE VALVE REQUIRED ON MAIN. A. UL-FM LISTED SOFTSEATED WA STATE APPROVED aa\tJ H. F <br /> FULL CIRCLE SEAL. REDUCED PRESSURE BACKFLOW ASSEMBLY Q�'pF WASy�y <br /> 2. ALL TEST COCKS MUST HAVE BRASS PLUGS. INCLUDING:2-O.S.&Y RESILIENT SEATED GATE <br /> 2. ALL TEES AND VALVES TO BE WATER TESTED VALVES,AND TEST COCKS. zm <br /> BEFORE TAP. z 3. MAXIMUM HEIGHT OF ASSEMBLY IS FIVE FEET <br /> 6" UNLESS AN OSHA APPROVED PLATFORM IS B. UNI-FLANGE WITH SETSCREWS OR MJ x FL <br /> 3. SIZE ON SIZE TAPS ALLOWED ONLY WITH MJ v PROVIDED. ADAPTOR WITH MEGA LUG OR GALVANIZED P 42766 2 <br /> TAPPING TEES.ALL OTHER TAPS SHALL BEAT SHACKLE TO MAIN WITH 2-3/4"RODS,OR MJ �'`F 9F�1 S 10, <br /> LEAST 2"SMALLER THAN THE EXISTING MAIN. 4. MINIMUM INSIDE VAULT HEIGHT I578",OR AS RETAINER GLANDS. `rS70N F.�G\ <br /> oDo APPROVED BY THE CITY UTILITIES DEPARTMENT. AL <br /> o�a <br /> 4. BRANCH LINE SHALL BE RESTRAINED AS IF A C. PRECAST CONCRETE ENCLOSURE WITH STEEL 2 24 23 <br /> DEAD-END PER SECTION 5-13. 5. MAXIMUM HEIGHT OF ASSEMBLY FROM FLOOR IS ACCESS HATCH(AS MANUFACTURED BY UTILITY <br /> z FIVE FEET UNLESS AN OSHA APPROVED PLATFORM GVAULT ROUND <br /> INS AL APPROVED D L:BE P).ABOVE c c - <br /> � IS PROVIDED. GROUND INSTALLATIONS WILL:BE PROVIDED WITH <br /> 776'-6'x36"STEEL DOOR FOR ACCESS,THE EXTERIOR <br /> 6. ALL DIMENSIONS ARE MINIMUM CLEARANCE WILL BE PAINTED WITH AN APPROVED PAINT, H g 2 i <br /> REQUIREMENTS. PROVIDED WITH SUFFICIENT INSULATION TO <br /> PREVENT FREEZING AND SITE WILL BE PROVIDED s <br /> 7. ASSEMBLY REQUIRES CERTIFICATION UPON WITH A 6'HIGH SECURITY FENCE WITH PEDESTRIAN <br /> PLAN PLAN A INSTALLATION AND RECERTIFICATION ANNUALLY BY AND VEHICLE GATES.SEMI-BURIED INSTALLATIONS u <br /> OWNER. WILL:BE PROVIDED WITH OSHA APPROVED S m <br /> PLAN LADDER.INSTALLED IN SUCH A WAY AS TO NOT <br /> INTERFERE WITH INSTALLED EQUIPMENT u <br /> MAINTENANCE.PROVIDE NON-SLIP SURFACE ON Q <br /> ACCESS HATCH IF VAULT LOCATED IN PEDESTRIAN 2 <br /> WALKWAY. 5 a <br /> A D. DUCTILE IRON PIPE(SIZED AS REQUIRED)CLASS 52. <br /> V <br /> ® ® ® E. WATERTIGHT GROUT SHALL BE USED IN ALL VAULT C <br /> ®O® PENETRATIONS. <br /> �c " <br /> ® ® ® F. 2-GALVANIZED ADJUSTABLE PIPE SUPPORTS FOR <br /> 1/2"DIA AND LARGER PIPE. a, N _ <br /> 7 L <br /> B G. GRAVEL FOUNDATION AS REQUIRED. = TO LI <br /> "� q m <br /> H. DRAIN SHALL BE INSTALLED WITH APPROVED AIR q N <br /> B GAP(SEE STD 519)AND BE ABLE TO BE BORE LU c N <br /> ELEVATION ELEVATION H SIGHTED TO DAYLIGHT WHICH MUST BE ABOVE C 0)M <br /> 100 YEAR FLOOD LEVEL.DRAIN WILL BE SIZED SO O <br /> ASTO PROVIDE FREE GRAVITY DRAINAGE OF MAX = QCIDN <br /> i DISCHARGE OF RELIEF VALVE PORT. M :01 <br /> 01 N <br /> INSTALLED ON ASBESTOS CEMENT PIPE, INSTALLED ON ASBESTOS CEMENT PIPE, 5L 3 N <br /> SLOPE OPE I. 3"MIN CLEARANCE FROM UNDERSIDE OF VAULT U) I-, <br /> i0 <br /> H (V <br /> w w .. <br /> CAST IRON PIPE AND DUCTILE IRON PIPE. CAST IRON PIPE AND DUCTILE IRON PIPE. s G� �rL <br /> LID TO STEM OF OS&Y WHEN FULLY OPEN. M C F4 C L <br /> o0 0°�0 �oro�68e soa�8o U W Y <br /> `s � <br /> a CAST IRON MECHANICAL JOINT STAINLESS STEEL F <br /> TAPPING TEE TAPPING SLEEVE CITY OF EVERETT o o CITY OF EVERETT <br /> PUBLIC WORKS DEPARTMENT E G D PUBLIC WORKS DEPARTMENT <br /> 2. 1-Inuil—L "_"" 12302016 wx "'•"&au V- `"'UM "'"'NRB "'•••."• <br /> 2 joojw-^ x REDUCED PRESSURE o9z4zo18 <br /> se TAPPING TEES µ514 Ism ELEVATION BACKFLOW ASSEMBLY 518 <br /> (RP A)ALL SIZES <br /> i <br /> City of Everett Permit Review N <br /> E <br /> Ev_ERE7T Status:Revisions Approved C o 0 <br /> 05/18/2023 3:05:46 PM ' N N T <br /> lJ <br />
The URL can be used to link to this page
Your browser does not support the video tag.