Laserfiche WebLink
WATERMAIN EXTENSION PLAN <br /> • SEC.12 SW,TOWNSHIP 28 N., RANGE 4 E. W.M. <br /> • <br /> Know what's below. F W <br /> Call before you dig. <br /> oom W <br /> F H F NOTES PARTS FOR 1" PARTS FOR 2" NOTES <br /> M I K A. 2"WATER MAIN SHALL BE POLYETHYLENE PER >j rc (A <br /> 1. AIR-VAC UNITAND BOXTO A. PROVIDE ROMAC,FORD A. PROVIDE ROMAC,FORD OR STANDARD DETAIL 502B.CONNECTION TO MAI TO zBE IN OR MUELLER SERVICE &J U <br /> SADDLE <br /> NON ED-TRAFFIC ICC AREA. SADDLE FOR DUCTILE ORELLER DUCTILE IRON OR DIPS BE MADE PER STANDARD DETAIL 502B. o M N J <br /> /\\ z G IRON OR DIPS HOPE HOPE MAIN F <br /> 2. USE MUELLER DOUBLE MAIN B. 2"BRASS MALE IRON PIPE THREAD X COMPRESSI i' � ��c <br /> \r STRAP SERVICE CLAMP OR B. 2"BALL CORP. FITTING WITH STAINLESS STEEL INSERT O o ooc� W O t/ <br /> APPROVED EQUAL ON ALL B. 1"FORD F600 SERIES STIFFENER.COUPLING SHALL BE"FORD"C84-77 E' o`�`�< W I.E. O <br /> p r MAINS LESS THAN 8"IN CORPORATION STOP. C. 2"TYPE"K"COPPER OR CITY APPROVED EQUAL. m n z m <br /> r a a a <br /> L DIAMETER. TUBING. a c <br /> C. 1'TYPE"K"COPPER E G C. 2"BRASS TEE(FIP). w w w w w <br /> 3. ALL PIPE FITTINGS BETWEEN TUBING. D. 2"90°ELL. (n o rn rn ut I1J W <br /> MAIN AND UNION,AFTER D. BRASS HEX BUSHING 2"X SERVICE SIZE, a�'�' <br /> AIR/VACUUM RELIEF VALVE, D. 1"FORD 602-44 ANGLE E. HEAVY DUTY 2"GATE A D A Q <br /> a ,- SHALL BE BRASS. COUPLING. VALVE WITH RESILIENT w <br /> ? SEAT.GATE VALVES SHALL E. CORPORATION STOP SHALL BE FORD FB700 OR 7i! s i i i i n <br /> m m m m m m 3"MIN CUR q, INSTALLATIONS LARGER E. 1"FORD 821-444 CURB BE"WAROVED SERIES 2500 APPROVED EQUAL. a W <br /> v g THAN 2"SIZE AIR/VACUUM STOP. OR APPROVED EQUAL. Q <br /> ssssmRELIEF VALVES SHALL BE F. METERED WATER SERVICE PER STANDARD 502A i <br /> J _ D INDIVIDUALLY DESIGNED F. 1"BRASS NIPPLE. F. 2"BRASS NIPPLE. 502C. �' m <br /> F AND WILL REQUIRE 41 y m O APPROVAL BY THE CITY G. 6"PVC PIPE. G. 2"OPERATING NUT c c c c <br /> //// UTILITIES DEPARTMENT. EXTENSION AND VALVE G. #10 COPPER TRACE WIRE WRAPPED ALONG EN Iii <br /> E H. 1"BRASS UNION. BOX PER STANDARD G B C B G WRAPPELENGTH(D AROUND ONE PTHE SADDLE BOTAND PER FOOT)WITH ONE END n H M w w <br /> 5. PAINT METER BOX LID AND DRAWING 505 <br /> N F 1"OPTION a RISER ASSEMBLY(2)COATS I. 1"BRASS ELL. SECURED BETWEEN 2 NUTS,ON MAIN N S <br /> H SAFETY YELLOW OIL BASE <br /> H. 2"BRASS UNION. CONNECTION.THE OTHER END WILL BE EXPOSE AENAMEL HAND N N <br /> A ,BRUSH J <br /> APPLIED 1"COMBINATION AIR THE METER BOX.A SCOTCH CAST ELECTRICAL < m <br /> ..STENCIL RISER AND VACUUM RELIEF I. 2"BRASS 90°ELL. SPLICE KIT TO BE USED TO SPLICE ALL WIRES WH <br /> F ASSEMBLY WITH"AV"AND VALVE CLA-VAL 36 SERIES REQURED.SCOTCH CAST ELECTRICAL SPLICE KIT <br /> 0 K SIZE OF AIR/VAC ASSEMBLY OR EQUAL. J. 2"COMBINATION AIRAND SERVICE CONNECTION PLAN SHALL 8E 3M INSULATION DISPLACEMENT z <br /> H ON SIDE FACING ROADWAY VACUUM RELIEF VALVE, <br /> N IN2"BLACK LETTERS. K. PROVI DE METER BOX CLA-VAL 365ERIES OR CONNECTORS OR CITY APPROVED EQUAL. <br /> \/ \/\\\ BODYMANUFACTURED EQUAL. <br /> VENT PIPE / \\ \/\\ /\\/ 6. AIR/VAC RELEASE VALVE BY"RAVEN PRODUCTS, <br /> ASSEMBLY SHALL BE MODEL RMD-15-27-12", K. PROVIDE METER BOX BODY LO <br /> (USED ON BOTH OPTIONS) \\/ //\\ \ \\' ON LAN EED AT HIGH H POINT FLUSH SOLID COVER LID. RAVEN PRODUCTSANUFACTURED , <br /> VENT PIPE PARTS L / /\ L. BACKFILL WITH RMD-17-30-12",FLUSH �\ ��/ <br /> / FALLS IN LOCATION WHERE \i\\ /�//� ADJUSTABLE VALVE BOX W <br /> L /� G ASSEMBLY CANNOT BE SAWDUST TO BONNET SOLID COVER LID. �� SEE C.O.E.STANDARD DWG 505 (y J <br /> N. 2"GALV PIPE. INSTALLED,PROVIDE AS APPLICABLE W <br /> ADDITIONAL DEPTH TO M.2"X1"GALV REDUCER. L. BACKFILL WITH SAWDUST 2"HEAVY DUTY P Ld <br /> O. 2"GALV 90°ELL(VERT). TO BONNET. BRASS NIPPLE 2"BRASS FORD MALE IRON PIPE THREAD."PACKJOINT" 5 5 0 Go <br /> CREATE NEW HIGH POINT. <br /> P. 2"GALV RETURN BEND. (` 7co <br /> . CONCRETE VAULT #C84-77 WITH INSERTSTIFFENER#55 OR APPROVED EQUAL. O co c <br /> PENETRATIONS SHALL BE <br /> 0, GALV SCREEN FOR 2" CORE DRILLED AND O W Q N W <br /> PIPE,MIN 24 MESH. GROUTED. 3 <br /> MIN #10 WIRE CHASER Z m <br /> CUR E o #10 COPPER WIRE ,` W O O <br /> O o WRAPPED ONCE 2"OD POLYETHYLENE(PE)PER WATER LINEV > Z nI <br /> = J F " AROUND SADDLE BOLT Q <br /> AWWA C901,SDR9(COPPERTUBE SIZE) O <br /> n SECURED BETWEEN Q = c v <br /> w 2 NUTS 2"HEAVY DUTY GATE VALVE L <br /> z I F H C 2 OPTION EVERETT PUBLIC WORKS MUELLER#A2380-8 WITH 2"DRIVE BLOCK CITY OF EVERETT W < <br /> B WASHINGTON DEPARTMENT4 PUBLIC WORKS DEPARTMENT (O Z <br /> os _'RMA _ _"LXELM HA%2022 a SERVICE CLAMP MUELLER BOUBLE 94171" P.uiwiwe�m °'""" 12]30`2016 0 <br /> o A �o ME1"pAND 2" STRAP OR APPROVED EQUAL x O <br /> s^ AIR VACUUM VALVE 512W c CONNECTION TO MAIN 2"POLYETHYLENE W <br /> ASSEMBLY Ic WATER MAIN 513 <br /> City of Everett Permit Review <br /> EVERETT Status:Revisions Approved <br /> 05/18/2023 3:05:46 PM <br /> H. <br /> UTILITY VAULT CO. PARTS NOTES \N WAsH NOTES SIZE MODEL COVER ° <br /> 2112' 644 B4-2332P Ol. POST INDICATOR VALVE(PIV)PAINTED RED WITH TAMPER TO FIRE ALARM PANEL 1. TEE AND GATE VALVE REQUIRED ON MAIN. <br /> 1. ALL INSTALLED AIR GAPS MUST BE WA DOH s° 544 64-2-33zP 18"X18"%8" AND WITH STENCILED ADDRESS(WHITE,2"HIGH TEXT). z <br /> APPROVED. a" 575 57TL-2_2P CONC.BLOCK 2. SINGLE DETECTOR CHECKS ARE NOT <br /> 6^ sn 57TL-"Sp <br /> O2. DUCTILE IRON PIPE(SIZED AS REQUIRED)CLASS 52. APPROVED BACKFLOW PREVENTION DEVICES. <br /> 2. THE HEIGHT OF THE AIR GAP MUST MEET THE B^ aa84 4484-TL2-332P 6 O3, SCHEDULE 40 GALV.STEEL WRAPPED W/6MIL PLASTIC. 3. ASSEMBLY REQUIRES CERTIFICATION UPON Ppf,qE,42766� <br /> ORAOBST UCTIONREST WALL IDE RIB POTABLE WATER SUPPLY CRITERIA IN TABLE A UNLESS OTHERWISE NOTED. Ja' St06 51D6TL333z O INSTALLATION AND RE-CERTIFICATION FSS��NA LLEE�G\� <br /> 4. CLASS 52 DI TEE FL X FL. ANNUALLY BY OWNER. <br /> 3. THE CITY o BE INCREASED <br /> DEPARTMENT IF I NT MAY REQUIRE THE 9 3 S O5. SWING CHECK VALVE W/BALL DRIP ASSEMBLY. <br /> AIR GAP TO BE INCREASED IF INSTALLED WITHIN A 4. ALLTEST COCKS MUST HAVE BRASS PLUGS. 2 24 23 <br /> BUILDING WHERE THE AIR PRESSURE 15 ARTIFICIALLY 3 O6. FIRE DEPARTMENT CONNECTION(FDC),BRASS.PROVIDE KNOX LOCKING CAPS. 5. ROUND MANHOLE LIDS ARE NOT TO BE USED. <br /> MAINTAINED OR INCREASED. EXPOSED GALVANIZED STEEL PIPE TO BE PAINTED RED.STENCIL ADDRESS(WHITE, - <br /> 2"HIGH TEXT)ON PAINTED PIPE. <br /> W EFFECTIVE DISCHARGE TO B B 6. INSIDE DEPTH 15 TO BE KEPT AT A M INI M UM ti e g a <br /> OPENING D" 4. AIR GAPS LESS THAN 1 INCH SHALL BE APPROVED g O AS PER DIMENSION IN SKETCHES ABOVE 5 H II 2 i <br /> NON-POTABLE ONLY ASA PART OF A LISTED DEVICE THAT HAS BEEN 3 7. ALL PIPE THROUGH VAULT WALL SHALL BE CORE DRILLED AND HAVE A"LINK SEAL" ii <br /> WATER SYSTEM TESTED UNDER BACKSIPHONAGE CONDITIONS 7 TO (OR APPROVED EQUAL). AND/OR AS APPROVED BY CITY OF EVERETT i <br /> OVERFLOW RIM ¢ UTILITIES DEPARTMENT. <br /> t7 WITHIN A VACUUM OF A MINIMUM OF 25 INCHES BUILDING Og, OS&YVALVES WITH TAMPER SWITCH TO ALARM PANEL OR CHAIN AND PADLOCK. <br /> OF MERCURY. - 7. METER SHALL BE INSTALLED SUCH THAT IT <br /> a O9. 1-GALV.LADDER WITH PULL-UP LADDER EXTENSION TO BE BOLTED TO VAULT CAN BE READ WITH ACCESS HATCH OPEN ut i <br /> 5. TUBULAR SCREENS MAY BE ATTACHED OR THE FLOOR AND TO VAULT WALL,MOUNTED SUCH THAT LADDER IS DIRECTLY ABOVE AND WITHOUT ENTERING THE VAULT. �I 3 m <br /> SUPPLY LINE OUTLET MAY BE CUTATA 45"ANGLE. a 1 q THE EDGE OF ACCESS OPENING FOR EASE OF ACCESS. o <br /> r r r r r r r r r r ALL DIMENSIONS ARE MINIMUM CLEARANCE. <br /> A TAMPER A 10 UL-FM LISTED SOFTSEATED WA STATE APPROVED DOUBLE CHECK DETECTOR 8. _ g u n <br /> 6. HOSES AND BYPASSES ARE NOT ALLOWED. 12 SW ITCH IF VALVE ASSEMBLY INCLUDING 2-O.S.&Y RESILIENTSEATED GATE VALVES,TEST o <br /> r r r r r r r r r r L- - - - 2 COCKS,3/4"BRASS OR COPPER BYPASS WITH IN LINE VALVES,5/8"X 3/4„ 9. ALL BACKFLOW DEVICES WILL BE INSTALLED S a 3 <br /> REQUIRED IN A VAULT OUTSIDE THE BUILDING UNLESS <br /> PUMP NEPTUNE METER W/E-CODER R90O I,CU FT W/STUB ANTENNA&A 3/4"DOUBLE <br /> 7. THE INSPECTION OF AIR GAPS SHALL BE INCLUDED CHECK VALVE ASSEMBLY. OTHERWISE APPROVED BY UTILITIES <br /> IN THE YEARLY TESTING PROGRAM FOR BACKFLOW 10 SUPERINTENDENT. C <br /> DE tj E <br /> VICES. PLAN 11 STATE APPROVED DOUBLE CHECK DETECTOR ASSEMBLY. FIRE SERVICE PIPINGS FROM MAIN TO L <br /> 13 12 RFCA(RESTRAINED FLANGE COUPLING ADAPTER). BUILDING SHALL BE RESTRAINED. - C <br /> 6 11. PROVISIONS FOR DRAINAGE OF THE VAULT <br /> LETTERS 13 CUTABLE PADLOCK WITH KEY IN KNOX BOX. i <br /> "AUTO TAMPER SHALL BE IN THE FOLLOWING ORDER OF d <br /> 41 *' A <br /> SPRINKLER" SWITCH IF DUAL 2-1/2"FEMALE FIRE DEPT PRECEDENCE: C � t <br /> ® REQUIRED O 1- 6 INLET CONNECTION BRASS(NOT A)VAULT DRAIN TO DAYLIGHT U IT <br /> _ PAINTED)"AUTO SPRINKLER" B)VAULT DRAIN TO STORM DRAIN SYSTEM q d <br /> TAMPER (IF PRACTICAL) U.I C <br /> SWITCH SCHEDULE 40 GALVANIZED STEEL C)IF NO POSSIBLE MEANS OF GRAVITY DRAIN, C N <br /> m ry � <br /> STENCILED CONC.BLO 0)M <br /> � PAINTED RED,STENCILED ADDRESS THEN INSTALL SUMP PUMP Qr � >� <br /> SO ADDRESS TO CONC.BLOCK N C Q 00 N - <br /> PAINTED WHITE <br /> FACE STREET 12. SWING CHECK VALVE ON FDC LINE MUST <br /> -- --- - -' LOCATED IN A VAULT.IF OUTSIDE OF DCDA <br /> ID - C Q `� <br /> VAULT,MUST BE IN MINIMUM 4'X4'VAULT. 3 N <br /> SCHEDULE40 H I" <br /> ° GALVANIZED STEEL 13. PIV LOC +ION MUST BE DOWNSTREAM OF i C U) N <br /> r R <br /> 4 WRAPPED WITH 6 DCDA AND UPSTREAM OF FDC. rD O F N - <br /> MIL <br /> PLASTIC <br /> 3 3 5 14. NEWFDCMUSTBE LOCATEDWITHIN 75'OFA <br /> F G 1 FIRE HYDRANT(OR 100'FOR AN EXISTING o <br /> INCHES $ 7 7 3 BUILDING BEING RETROFIT FOR SPRINKLERS). <br /> AIR GAP <br /> 7 NEW FIRE HYDRANT INSTALLATION MAY BE R <br /> D IF W>3D IF W 5 3D(SINGLE WALL)OR o NEEDED TO MEET CODE REQUIREMENT <br /> IF W<_4D INTERSECTING WALLS <br /> <0.5 INCH 1 1 1.5 3 <br /> 0 <0.75 INCH 1.5 2.25 n z a 2 7 TYPICAL WHEN FIRE ROOM IS MORE THAN 70'FROM MAIN i <br /> t11NCH 2XD q <br /> 3XD R 11� �N 0 EVERETT <br /> CITY OF EVERETT g PUBLIC WORKS <br /> PROVIDE 9"MINIMUM AND 12"MAXIMUM DEPARTMENT <br /> PUBLIC WORKS DEPARTMENT mti CLEARANCE BETWEEN VAULT FLOOR AND BOTTOM WASHINGTON <br /> TABLE A _ o OF BACKFLOW ASSEMBLY.WHERE ELEVATION OF 2 j <br /> 3 a a xiiii" Pa"iwiExeEm 03 07 2017 B POSITIVE VAULT DRAIN VAULT FLOOR ISTOO LOW TO DRAIN TO DAYLIGHT r`nv"ary srss n�xitli'°" P'nLiwi,xeEm °"'"wxe `1�2/a020 0 <br /> L+ OR STORM SYSTEM,MUST HAVE6"FLOOR DOUBLE CHECK DETECTOR <br /> AIR GAP FOR " OPENING FOR DRAINAGE(APPROVED BY THE CITY E u <br /> ;s^ MAKEUP TANK 519 ;s DCDVA ELEVATION A-A ENGINEER ON A CASE BY CASE BASIS ONLY). FDC ELEVATION B-B VALVE ASSEMBLY W/FDC&PIV 515 04 ` o <br /> (DCDA)2"&LARGER SERVICE 04 m o <br />