' r <br /> Verizon Communications-Stormwater Site Plan Everett, WA <br /> II. Preliminary Conditions Summary <br /> Existing Conditions <br /> The existing site is fully developed and generally flat. The 9.12 acre portion of the site <br /> covered by this report is shown on Exhibit A — Pre-Developed Conditions Map. The USGS <br /> defines the site soils as Alderwood-Urban land complex. <br /> Table 1 — Existing Land Coverage <br /> Existing <br /> SF Acres <br /> Pervious 88,759 2.038 <br /> Gravel 69,418 1.594 <br /> PGIS* 235,193 5.399 <br /> Roof top 3,879 0.089 <br /> TOTAL 397,249 9.120 <br /> *Pollution-Generating Impervious Surface <br /> The surface run-off is collected by the onsite conveyance system and is conveyed to the <br /> City of Everett public storm drainage system at the northeast corner of the site. There are <br /> no existing water quality or flow control measures in place for the portion of the <br /> development covered by this report. Downstream of the site, the public system continues <br /> east along West Casino Road. <br /> Discharge at Natural(Existing) Location <br /> No change is proposed to the existing onsite drainage system connection to the closed <br /> system within West Casino Road. <br /> Wells, Septic Tanks and Fuel Tanks <br /> There are no known fuel tanks, wells or septic tanks located on the property. The former <br /> onsite fueling station has already been removed and it is assumed that any fuel tanks <br /> associated with the station were removed at that time. If at a later date one is discovered <br /> on the property, it will be removed in accordance with all regulatory requirements, local, <br /> state and federal. <br /> PACLAND Job#50183001 Page 3 <br />