E01 FACE / HALO LIT CHANNEL LETTERS ON PANEL 44-PC FACEMALO LIT LED BACKER <br /> Scale: 1/2"=V-0" 35.6 square feet <br /> a rox. 201.41 I bs SS Threaded Rod w/ p Spacer <br /> pp Hex Nut&Nylock Washer Aluminum returns <br /> Silicone caulk all penetrations Pan head screw <br /> Steel Angle or approved ® Trimcap <br /> 4-1/2" 2-1/2" blocking <br /> 98-8-1/2EE Backer& Swoosh Plastic Bushing Rubber Disconnect Switch <br /> 3-1/2"� Wire Nut n <br /> Junction Box Acrylic Face <br /> Rubber disconnect Electrical conduit ACM baffle <br /> switch on top right &fitting <br /> 1'-6-5/8" side of panel Anchor bolt(may vary) 18 ga PLTC Wire <br /> p w/mounting angle Crimp Connector <br /> 3N_$EN SwooshrEXTR Bolt,Hex head,1/4"20 <br /> w/nut&washer <br /> Backer , " A <br /> M I L E V-1/4" -- LED modules <br /> -5-5/8 #lsga PLrc wire <br /> Power supply box <br /> Power suppl Polycarbonate Back <br /> 1 <br /> 8-1/8" Stud for Grounding <br /> 12 ga Stranded THHN Wire 3/8"Riv nut w/hex bolt <br /> Fitting&Conduit-To Primary &lock washer <br /> 5-3-3/4" 2'-11-7/8" Disconnect Switch wl lock i Weep holes 5/16"dia <br /> w/light baffle if req'd. <br /> 12 ga Stranded THHN Wire 4mm ACM backer w/ Exterior locations only <br /> FACES: SWOOSH&"MILE":3/16"#7328 White acrylic w/surface applied trans.Yellow vinyl overlays; Fitting&Conduit-To Primary internal angle framework <br /> "EXTRA": 3/16"#7328 White acrylic MOUNTING METHOD:* SISA TO BE O.L.LISTED AL AD ROVE <br /> LD MARNENTSTO BED.L LISTED <br /> OB, <br /> (Use appropriate method following wall inspection) AXO SHALL MEET N.E.C.STANDARDS AP BE HLEDANOMARKEDPERNEC BEE <br /> ALL i0 BE ELECTRICALLY GROUNDER PER N E.C.250. <br /> IBA—riLers ALL POWER SUPPLIES TO BE FUSED PER U.L 48,28.2.1 <br /> TRIMCAP: SWOOSH:3/4"Yellow Jewelite trimcap;All trimcap seams to be on top of swoosh Thru bolt-all thread fasteners w/wood blocking or angle iron stringer UL Leberz/EeliES IRE. RRRNDIS GNDD S MEET PER <br /> CEACN 2D50-9L,-992;94;9B. <br /> "EXTRA MILE": 3/4"Gray Jewelite trimcap;All trimcap seams to be on top of letters Toggle boltswlhollowcore- wood backing �M�I ELECTRIC SIGNGrver S 48 <br /> TANDARDUNDING HGTRIGALSIGNS <br /> gg plywood 9 GROUNDING&BONDING <br /> Kwik Bolts or Expansion lag bolts&shields w/solid concrete As PER NE C.25G 90&NEC BDD <br /> IS <br /> RETURNS: SWOOSH:3-1/2"deep .040 alum. painted Yellow; <br /> "EXTRA MILE":4-1/2"deep.040 alum. painted Gray <br /> City of Everett Permit Review THIS SIGN IS INTENDED TO BE INSTALLED IN <br /> BACKS: 3/16"Clear polycarbonate w/second surface applied Red vinyl overlays ` Y ACCORDANCE WITH THE REQUIREMENTS OF <br /> EVERETT Status: Reviewed for Permit ARTICLE 6000FTHE NATIONAL ELECTRICAL <br /> ILLUM.: FACE ILLUM.(All letters and swoosh):Sloan Prism12 6500K White LED's as required by manufacturer, WASHINGTON CODE AND/OR OTHER APPLICABLE LOCAL <br /> SWOOSH HALO ILLUM.: Sloan Prism12 Red LED's as required b manufacturer; 03/20/2024 9:55:41 AM CODES.THIS INCLUDES PROPER GROUNDING <br /> q Y AND BONDING OF THE SIGN. <br /> "EXTRA MILE"HALO ILLUM.:Sloan Prism12 Red&6500K White LED's as required by manufacturer; <br /> Interior 4mm ACM baffle for all letters and swoosh; See following page for LED layouts; THE LOCATION OF THE DISCONNECT SWITCH <br /> REMOTE POWER SUPPLIES;All UL labels to be applied on the bottom right of each illuminated sign; AFTER INSTALLATION SHALL COMPLY WITH <br /> pp 9 9 ARTICLE 600.6(A)(1)OF THE NATIONAL <br /> Power to run through standoff,not a separate penetration; Exterior rubber disconnect switch to be added ELECTRIC CODE. <br /> BACKER: 1-1/21'x 1-1/2"x 1/8"angle frame glued to brake formed 4mm TOR Red Alpolic ACM with 2-1/2"returns; COLOR PALETTE SIMULATED NIGHT VIEW <br /> 2"x 2"x 1/8"angle frame for attaching to wall TOR Red Alpolic ACM <br /> 3M 3630-73 Dark Red <br /> WALL MAT.: Not provided at time of survey <br /> O PMS 7405 C Yellow <br /> INSTALL: Extra Mile&Swoosh to be pin mounted off backer surface with 1"x 1/2"dia.spacer painted to match backer 3M 3630-15 Yellow <br /> to allow for halo illumination; Backer thru bolted to wall surface using all thread into blocking as required; oamm<ow in <br /> 12"standard length of threaded rod will be supplied unless otherwise noted;3/8"threaded rod into blocking EXTRAMILE <br /> or Stratus approved equivalent;All nuts are to be Nylock to resist back out;Spacers to be provided and PMS Cool Gray 10 C <br /> painted to match backer; Eye bolt to be removed and plug to be inserted and painted red to match after install is complete <br /> ONE LETTERSET on BACKER REQUIRED FOR FRONT ELEVATION All <br /> unnle sf onishes therwisehno edtin <br /> to <br /> QUANTITY: (1) <br /> CLIENT: ORDER NUMBER: PROJECT NUMBER: Rev# Req# Date/Artist Description Rev# Req# Date/Artist Description <br /> 1205420 86352 Original 460746 01/19/24 BS <br /> L Rev 1 463337 02/13/24 Z-SA <br /> I <br /> SITE NUMBER: PROJECT MANAGER: <br /> _ ADDRESS: PAGE NO.: 1117 KEVIN HORNE <br /> _ 10921 19th Ave Se ELECTRONIC FILE NAME: <br /> -• • • • •.• Everett,WA 5 GACCOUNTS\0\CHEVRON PRODUCTS CO\EXTRA MILE\LOCATIONS\2024\WA\1117_Everett\ <br /> 98208-5154 111 7 Everett R1.cdr ... <br />