My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
304 SE EVERETT MALL WAY PANERA BREAD 2025-07-25
>
Address Records
>
SE EVERETT MALL WAY
>
304
>
PANERA BREAD
>
304 SE EVERETT MALL WAY PANERA BREAD 2025-07-25
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/25/2025 1:18:35 PM
Creation date
7/25/2025 1:17:05 PM
Metadata
Fields
Template:
Address Document
Street Name
SE EVERETT MALL WAY
Street Number
304
Tenant Name
PANERA BREAD
Notes
STORMWATER MANAGEMENT REPORT
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
108
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Design Flow Treated Sediment Load <br /> per BFC-(gpm) (Ibs) <br /> Nominal <br /> 30 150 <br /> 23 200 <br /> 20 250 <br /> 15 300 <br /> 2.3 PRECAST CONCRETE VAULT COMPONENTS <br /> A. Concrete structures shall be designed for H-20 traffic loading and <br /> applicable soil loads or as otherwise determined by a Licensed Professional <br /> Engineer. The materials and structural design of the devices shall be per <br /> ASTM C857 and ASTM C858. <br /> B. The minimum compressive strength of the concrete shall be 4000 psi. <br /> C. Cement shall conform to the requirements for Portland cement of <br /> Specification C 150. <br /> D. Aggregates shall conform to Specification C33, except that the requirement <br /> for gradation shall not apply. <br /> E. Reinforcement shall consist of wire conforming to Specification A82 or <br /> Specification A496, of wire fabric conforming to Specification A185 or <br /> Specification A497, or of bars of Grade 40 steel conforming to <br /> Specification A615/A615M. <br /> F. The access cover shall be designed for HS20-44 traffic loading and shall <br /> provide a minimum 30 inch clear opening. <br /> G. All joints shall be waterproof with wrapped gaskets or sealed with a mastic <br /> treatment. <br /> H. Any grout used within the system shall meet the ASTM C 1107 "Standard <br /> Specification for Packaged Dry, Hydraulic-Cement Grout (Non-Shrink)". <br /> Grades A, B and C at a pourable and plastic consistency at 70°F. CRD C <br /> 621 "Corps of Engineers Specification For Non-Shrink Grout." <br /> 2.4 CONTRACTOR PROVIDED COMPONENTS <br /> Specifications for all contractor-provided components are minimum requirements. <br /> If a higher standard is shown on the plans or described in another section of the <br /> technical specifications, then the higher standard shall govern. <br /> BaySaver Technologies,Inc. 3 03/31/09-Version 2.0 <br />
The URL can be used to link to this page
Your browser does not support the video tag.