My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
304 SE EVERETT MALL WAY PANERA BREAD Geotech Report 2025-07-25
>
Address Records
>
SE EVERETT MALL WAY
>
304
>
PANERA BREAD
>
Geotech Report
>
304 SE EVERETT MALL WAY PANERA BREAD Geotech Report 2025-07-25
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/25/2025 1:22:09 PM
Creation date
7/25/2025 1:20:38 PM
Metadata
Fields
Template:
Address Document
Street Name
SE EVERETT MALL WAY
Street Number
304
Tenant Name
PANERA BREAD
Address Document Type
Geotech Report
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
40
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
KA No.092-12004 <br /> August 24,2012 <br /> Page No. 10 <br /> should not be allowed. In addition, adequate ventilation of the structure is recommended to reduce the <br /> accumulation of interior moisture. <br /> Temporary Excavations <br /> The on site soils have variable cohesion strengths,therefore the safe angles to which these materials may <br /> be cut for temporary excavations is limited, as the soils may be prone to caving and slope failures in <br /> temporary excavations deeper than 4 feet. Temporary excavations in the medium dense native soils <br /> should be sloped no steeper than 1H:1 V(horizontal to vertical)where room permits. <br /> All temporary cuts should be in accordance with Washington Administrative Code (WAC) Part N, <br /> Excavation, Trenching, and Shoring. The temporary slope cuts should be visually inspected daily by a <br /> qualified person during construction work activities and the results of the inspections should be included <br /> in daily reports. The contractor is responsible for maintaining the stability of the temporary cut slopes <br /> and minimizing slope erosion during construction. The temporary cut slopes should be covered with <br /> plastic sheeting to help minimize erosion during wet weather and the slopes should be closely monitored <br /> until the permanent retaining systems are complete. Materials should not be stored and equipment <br /> operated within 10 feet of the top of any temporary cut slope. <br /> A Krazan & Associates geologist or geotechnical engineer should observe, at least periodically, the <br /> temporary cut slopes during the excavation work. The reason for this is that all soil conditions may not <br /> be fully delineated by the limited sampling of the site from the geotechnical explorations. In the case of <br /> temporary slope cuts, the existing soil conditions may not be fully revealed until the excavation work <br /> exposes the soil. Typically, as excavation work progresses the maximum inclination of the temporary <br /> slope will need to be evaluated by the geotechnical engineer so that supplemental recommendations can <br /> be made. Soil and groundwater conditions can be highly variable. Scheduling for soil work will need to <br /> be adjustable, to deal with unanticipated conditions, so that the project can proceed smoothly and <br /> required deadlines can be met. If any variations or undesirable conditions are encountered during <br /> construction, Krazan & Associates should be notified so that supplemental recommendations can be <br /> made. <br /> Structural Fill <br /> Fill placed beneath foundations, pavement, or other settlement-sensitive structures should be placed as <br /> structural fill. Structural fill, by definition, is placed in accordance with prescribed methods and <br /> standards, and is monitored by an experienced geotechnical professional. Field monitoring procedures <br /> would include the performance of a representative number of in-place density tests to document the <br /> attainment of the desired degree of relative compaction. The area to receive the fill should be suitably <br /> prepared as described in the Site Preparation subsection of this report prior to beginning fill placement. <br /> Typically, imported structural fill material should consist of well-graded gravel or sand and gravel <br /> mixture with a maximum grain size of 3 inches and less than 5 percent fines (material passing the U.S. <br /> Krazan&Associates,Inc. <br /> Eleven Offices Serving The Western United States <br />