Laserfiche WebLink
I <br /> Exisitng Basin Event Summary <br /> IEvent Peak Q (cfs) Peak T (hrs) Hyd Vol (acft) Area (ac) Method <br /> 2 yr 24 hr 0.2506 8.00 0.0967 1.26 SBUH <br /> 1 10 year 0.5091 8.00 0.1884 1.26 SBUH <br /> 100 year { 0.7013 ( 8.00 0.2561 I 1.26 I SBUH <br /> IAll results based on storm duration of 24.0 hours. This is ok if all precipitations are <br /> appropriate for the storm duration. If some design event precipitations are for different <br /> duration storms, those results are incorrect <br /> I <br /> Record Id: Exisitng Basin <br /> IDesign Method SBUH Rainfall type TYPE1A.RAC <br /> Hyd Intv 10.00 min Peaking Factor 484.00 <br /> IStorm Duration 24.00 hrs Abstraction Coeff 0.20 <br /> Pervious Area 0.64 ac DCIA 0.62 ac <br /> I Pervious CN 86.00 DC CN 98.00 <br /> Pervious TC 10.00 min DC TC I 10.00 min <br /> I Pervious CN Calc <br /> Description SubArea Sub cn <br /> 0.64 ac 86.00 <br /> IPervious Composited CN(AMC 2) 86.00 <br /> I <br /> Pervious TC Calc <br /> Type Description Length Slope Coeff Misc TT <br /> Sheet I I 0.00 ft 1 0.0% I 10.0 I 0.00 in 10.00 min <br /> IPervious TC I 10.00 min <br /> I <br /> DCI- CN Calc <br /> Description SubArea Sub cn <br /> I 0.62 ac 98.00 <br /> II DC Composited CN(AMC 2) I 98.00 <br /> I <br /> DCI - TC Calc <br /> Type Description Length Slope Coeff Misc TT <br /> Sheet I I 0.00 ft I 0.0% 10.0 I 0.00 in 10.00 min <br /> II Pervious TC 10.00 min <br /> I <br />