My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1606 SE EVERETT MALL WAY ANTHEM SELF STORAGE 2025-07-25
>
Address Records
>
SE EVERETT MALL WAY
>
1606
>
ANTHEM SELF STORAGE
>
1606 SE EVERETT MALL WAY ANTHEM SELF STORAGE 2025-07-25
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/25/2025 2:44:55 PM
Creation date
7/25/2025 2:42:55 PM
Metadata
Fields
Template:
Address Document
Street Name
SE EVERETT MALL WAY
Street Number
1606
Tenant Name
ANTHEM SELF STORAGE
Notes
DRAINAGE REPORT AND STORMWATER POLLUTION PREVENTION PLAN (SWPPP)
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
119
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I <br /> have a bulk density ranging from 6.5 to 8.5 lbs per cubic foot and particle <br /> sizes ranging from 0.09" (#8 mesh) to 0.38" (3/8" mesh). <br /> • Zeolite Media: Zeolite media shall be made of naturally occurring <br /> clinoptilolite. The zeolite media shall have a bulk density ranging from <br /> 44 to 50 lbs per cubic foot and particle sizes ranging from 0.13" (#6 mesh) <br /> to 0.19" (#4 mesh). Additionally,the cation exchange capacity(CEC) of <br /> zeolite shall range from approximately 1.0 to 2.2 meq/g. <br /> • Granular Activated Carbon: Granular activated carbon (GAC) shall be <br /> made of lignite coal that has been steam-activated. The GAC media shall <br /> have a bulk density ranging from 28 to 31 lbs per cubic foot and particle <br /> sizes ranging from a 0.09" (#8 mesh) to 0.19" (#4 mesh). <br /> Applicant: Contech Engineered Solutions <br /> Applicant's Address: 11835 NE Glenn Widing Dr. <br /> Portland, OR 97220 <br /> Application Documents: <br /> The applicant's master report, titled, "The Stormwater Management StormFilter <br /> Basic Treatment Application for General Use Level Designation in Washington", <br /> Stormwater Management, Inc.,November 1, 2004, includes the following reports: <br /> • (Public)Evaluation of the Stormwater Management StormFilter Treatment <br /> System:Data Validation Report and Summary of the Technical Evaluation <br /> Engineering Report(TEER) by Stormwater Management Inc., October 29, 2004 <br /> Ecology's technology assessment protocol requires the applicant to hire an <br /> independent consultant to complete the following work: <br /> 1. Complete the data validation report. <br /> 2. Prepare a TEER summary, including a testing summary and conclusions <br /> compared with the supplier's performance claims. <br /> 3. Provide a recommendation of the appropriate technology use level. <br /> 4. Recommend relevant information to be posted on Ecology's website. <br /> 5. Provide additional testing recommendations, if needed." <br /> 6. This report, authored by Dr. Gary Minton, Ph. D., P.E., Resource Planning <br /> Associates, satisfies the Ecology requirement. <br /> • (Public) "Performance of the Stormwater Management StormFilter Relative to the <br /> Washington State Department of Ecology Performance Goals for Basic <br /> Treatment," is a summary of StormFilter performance that strictly adheres to the <br /> criteria listed in the Guidance for Evaluating Emerging Stormwater Treatment <br /> Technologies, Technology Assessment Protocol—Ecology(TAPE). <br /> I <br /> CONTECH-StorrnFilter®GULD Maintenance Update(November 2012) P a g e 14 <br /> I <br />
The URL can be used to link to this page
Your browser does not support the video tag.