My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1606 SE EVERETT MALL WAY ANTHEM SELF STORAGE 2025-07-25
>
Address Records
>
SE EVERETT MALL WAY
>
1606
>
ANTHEM SELF STORAGE
>
1606 SE EVERETT MALL WAY ANTHEM SELF STORAGE 2025-07-25
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/25/2025 2:44:55 PM
Creation date
7/25/2025 2:42:55 PM
Metadata
Fields
Template:
Address Document
Street Name
SE EVERETT MALL WAY
Street Number
1606
Tenant Name
ANTHEM SELF STORAGE
Notes
DRAINAGE REPORT AND STORMWATER POLLUTION PREVENTION PLAN (SWPPP)
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
119
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I <br /> I <br /> INo. 3—Closed Detention Systems(Tanks/Vaults) <br /> Maintenance Defect Conditions When Maintenance is Needed Results Expected <br /> Component When Maintenance is <br /> I Performed <br /> Storage Area Plugged Air Vents One-half of the cross section of a vent is Vents open and <br /> blocked at any point or the vent is damaged. functioning. <br /> I Debris and Sediment Accumulated sediment depth exceeds 10% All sediment and <br /> of the diameter of the storage area for 1/2 debris removed from <br /> length of storage vault or any point depth storage area. <br /> exceeds 15%of diameter. <br /> I (Example: 72-inch storage tank would <br /> require cleaning when sediment reaches <br /> depth of 7 inches for more than 1/2 length of <br /> tank.) <br /> I Joints Between Any openings or voids allowing material to All joint between <br /> Tank/Pipe Section be transported into facility. tank/pipe sections <br /> are sealed. <br /> (Will require engineering analysis to <br /> I determine structural stability). <br /> Tank Pipe Bent Out Any part of tank/pipe is bent out of shape Tank/pipe repaired or <br /> of Shape more than 10%of its design shape. (Review replaced to design. <br /> required by engineer to determine structural <br /> Istability). <br /> Vault Structure Cracks wider than 1/2-inch and any Vault replaced or <br /> Includes Cracks in evidence of soil particles entering the repaired to design <br /> I Wall, Bottom, structure through the cracks, or specifications and is <br /> Damage to Frame maintenance/inspection personnel structurally sound. <br /> and/or Top Slab determines that the vault is not structurally <br /> sound. <br /> I Cracks wider than 1/2-inch at the joint of any No cracks more than <br /> inlet/outlet pipe or any evidence of soil 1/4-inch wide at the <br /> particles entering the vault through the walls. joint of the inlet/outlet <br /> pipe. <br /> I Manhole Cover Not in Place Cover is missing or only partially in place. Manhole is closed. <br /> Any open manhole requires maintenance. <br /> Locking Mechanism Mechanism cannot be opened by one Mechanism opens <br /> Not Working maintenance person with proper tools. Bolts with proper tools. <br /> I <br /> into frame have less than 1/2 inch of thread <br /> (may not apply to self-locking lids). <br /> Cover Difficult to One maintenance person cannot remove lid Cover can be <br /> I Remove after applying normal lifting pressure. Intent removed and <br /> is to keep cover from sealing off access to reinstalled by one <br /> maintenance. maintenance person. <br /> Ladder Rungs Unsafe Ladder is unsafe due to missing rungs, Ladder meets design <br /> I misalignment, not securely attached to standards.Allows <br /> structure wall, rust,or cracks. maintenance person <br /> safe access. <br /> Catch Basins See"Catch Basins" See"Catch Basins"(No.5). See"Catch Basins" <br /> I <br /> (No. 5) (No.5). <br /> I <br /> I <br /> 4-34 Volume V—Runoff Treatment BMPs February 2005 <br /> I <br />
The URL can be used to link to this page
Your browser does not support the video tag.