My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1606 SE EVERETT MALL WAY ANTHEM SELF STORAGE Geotech Report 2025-07-25
>
Address Records
>
SE EVERETT MALL WAY
>
1606
>
ANTHEM SELF STORAGE
>
Geotech Report
>
1606 SE EVERETT MALL WAY ANTHEM SELF STORAGE Geotech Report 2025-07-25
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/25/2025 2:51:06 PM
Creation date
7/25/2025 2:49:52 PM
Metadata
Fields
Template:
Address Document
Street Name
SE EVERETT MALL WAY
Street Number
1606
Tenant Name
ANTHEM SELF STORAGE
Address Document Type
Geotech Report
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
32
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I <br /> I <br /> Subsurface Exploration, Geologic Hazard, and <br /> 11 Krebs Property Preliminary Geotechnical Engineering Report <br /> Everett, Washington Preliminary Design Recommendations <br /> 1 10.0 FOUNDATIONS <br /> 10.1 Allowable Soil Bearing Pressure <br /> ISpread footings may be used for building support when founded either directly on the medium <br /> dense to very dense, natural glacial sediments, or on structural fill placed over these materials, <br /> I as described under the Site Preparation and Structural Fill sections of this report. For footings <br /> founded either directly upon the medium dense to very dense till, or on structural fill as <br /> described above, we recommend that an allowable bearing pressure of 2,500 pounds per square <br /> I foot (psf) be used for design purposes, including both dead and live loads. Sediments suitable <br /> for foundation support were generally encountered in our explorations at depths of <br /> approximately 1.5 to 3 feet. If higher bearing pressures are needed, a value of 4,000 psf may <br /> 1 be used in areas where all footings are placed entirely on the undisturbed dense to very dense <br /> lodgement till. Dense to very dense lodgement till sediments were encountered in our <br /> explorations at depths of approximately 2.5 to 4 feet. An increase of one-third may be used <br /> Ifor short-term wind or seismic loading. <br /> 10.2 Minimum Footing Embedment <br /> IPerimeter footings for the proposed buildings should be buried a minimum of 18 inches into <br /> the surrounding soil for frost protection. No minimum burial depth is required for interior <br /> I footings; however, all footings must penetrate to the prescribed stratum, and no footings <br /> should be founded in or above loose, organic, or existing fill soils. <br /> 1 10.3 Footings Adjacent to Cuts <br /> The area bounded by lines extending downward at 1H:1V from any footing must not intersect <br /> Ianother footing or intersect a filled area that has not been compacted to at least 95 percent of <br /> ASTM:D 1557. In addition, a 1.5H:1V line extending down from any footing must not <br /> daylight because sloughing or raveling may eventually undermine the footing. Thus footings <br /> Ishould not be placed near the edges of steps or cuts in the bearing soils. <br /> 10.4 Footing Settlement <br /> I <br /> Anticipated settlement of footings founded as described above should be on the order of 1 inch <br /> or less. However, disturbed soil not removed from footing excavations prior to footing <br /> Iplacement could result in increased settlements. <br /> I10.5 Footing Subgrade Bearing Verification <br /> All footing areas should be observed by AESI prior to placing concrete to verify that the <br /> Iexposed soils can support the design foundation bearing capacity and that construction <br /> February 13, 2007 ASSOCIATED EARTH SCIENCES,INC. <br /> ITJP/ed-KE070023A1-Projects1200700231KEIWP Page 11 <br />
The URL can be used to link to this page
Your browser does not support the video tag.