My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
8102 EVERGREEN WAY EVERETT 4 CORNERS - BLDG C 2025-08-06
>
Address Records
>
EVERGREEN WAY
>
8102
>
EVERETT 4 CORNERS - BLDG C
>
8102 EVERGREEN WAY EVERETT 4 CORNERS - BLDG C 2025-08-06
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/6/2025 8:11:56 AM
Creation date
7/28/2025 7:05:06 AM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
8102
Tenant Name
EVERETT 4 CORNERS - BLDG C
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
618
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
L0 <br />0 <br />0 <br />w <br />0 <br />N <br />O <br />N <br />N <br />L: <br />C.101 <br />X <br />a) <br />co <br />I <br />z <br />I <br />a) <br />U <br />U) <br />I <br />L <br />a) <br />L <br />O <br />U <br />L <br />0 <br />IL <br />I— <br />N <br />00 <br />a) <br />E <br />U <br />O <br />0 <br />X <br />a) <br />g <br />U <br />L <br />A <br />SHEET NOTES <br />C.g C.j C.k C.n <br />1. LEVELS 2-6 TYPE VA CONSTRUCTION <br />R2 OCCUPANCIES <br />I <br />2. ALL LEVELS FULLY SPRINKLERED PER <br />IBC SECTION 903.3.1.1 (NFPA 13). <br />,'D,.8 <br />101 <br />141 <br />1 A333 <br />2 A333 <br />3 REFER TO SHEETS CS03 FOR FIRE <br />ASSEMBLY KEY PLAN W/ WALL TYPE <br />TAGS & LOCATIONS. REFER TO <br />SHEET SERIES A040 FOR ASSEMBLY <br />DETAILS. <br />4. SEE ENLARGED UNIT PLANS FOR ALL <br />INTERIOR DIMENSIONS, WINDOW AND <br />DOOR CALL -OUTS, AND RATED WALL <br />TAGS <br />5. EXIT STAIR ENCLOSURES IN TYPE 1A <br />CONSTRUCTION SHALL BE 3-HOUR <br />RATED <br />ALL VERTICAL SHAFTS SHALL BE 2- <br />6' HOUR RATED PER IBC SECTION 713.4. <br />7. ODOOR TYPE - SEE SCHEDULE <br />SHEET A100 <br />8. REFER TO SHEET SERIES A100 FOR <br />UNIT PLAN DOOR & WINDOW <br />SCHEDULE. <br />9. REFER TO SHEETS A110, A120, <br />A130, A140, A150 & A151 FOR <br />ENLARGED UNIT PLANS. <br />10. REFER TO ACCESSIBILITY NOTES <br />ON SHEET CS00 <br />11. PROVIDE MECHANICALLY <br />FASTENED INSULATION AT ALL <br />CEILINGS BETWEEN CONDITIONED <br />AND UNCONDITIONED SPACE, <br />REFER TO SHEET A040 FOR <br />REQUIRED R-VALUES. <br />12. CORRIDOR VENTILATION CONCEPT <br />SHOWN, REFER TO DESIGN/BUILD <br />MECHANICAL PLANS. <br />F.E.C. <br />RECESSED/FIRE EXTINGUISHER <br />13. <br />CABINET <br />6 <br />SEE DETAIL: <br />A051 <br />-0F.E. <br />SURFACE MOUNTED FIRE <br />14. <br />EXTINGUISHER CABINET <br />LOCATE PER IBC TABLE 906.3 <br />(1) 75 FT. MAX. SEPARATION - <br />PARKING GARAGE LEVEL ONLY <br />SEE DETAIL 3/A051 FOR <br />MOUNTING/INSTALLATION <br />HEIGHT <br />15. EXIT <br />SIGN PER IBC SECTION 1013. <br />16. REFER TO DESIGN/BUILD <br />ELECTRICAL PLANS. <br />17. REFER TO SHEET A051 FOR <br />PENETRATION REQUIREMENTS IN <br />FIRE RATED CONSTRUCTION. <br />18. REFERENCE BUILDING ENVELOPE <br />DRAWINGS FOR ALL WATERPROOFING. <br />19 INDICATES TYPE A ACCESSIBLE UNIT. <br />ALL REMINING UNITS SHALL MEET TYPE <br />B ACCESSIBLE UNIT REQUIREMENTS <br />PER IBC SECTION 1107.6.2 <br />20 UNIT DEMISING WALLS ARE 1 HOUR <br />RATED PER IBC SECTION 708 W/ <br />MINIMUM STC 50. SEE SHEETS A040&A041 <br />21. ® INDICATES TYPE W UNIT <br />22. AT DOORS INTO ELECTRICAL CONTROL <br />PANEL ROOMS, SIGNAGE SHALL BE <br />PROVIDED ON THE DOOR STATING <br />'ELECTRICAL ROOM' <br />23. AT DOORS INTO FIRE PROTECTION <br />EQUIPMENT ROOMS CONTAINING <br />SPRINKLER RISERS, FACP, OR OTHER <br />SUPPRESION CONTROL ELEMENTS, <br />APPROVED SIGNAGE SHALL BE <br />PROVIDED AND READILY VISIBLE PER <br />IFC SECTION 509.1 <br />24. -TWO-WAY COMMUNICATION <br />SYSTEM PER IBC SECTION 1009.8 <br />KEY PLAN <br />OHNSON BRAUNDINC. <br />15200 52nd Ave. South <br />Suite 300 <br />Seattle, WA 98188 <br />Phone 206.766.8300 <br />www.johnsonbraund.com <br />ARCHITECTURE <br />INTERIOR DESIGN <br />Greg L. Allwine, <br />Jeffrey A. Williams, <br />8556 <br />REGISTERED <br />ARCHITECT <br />eFFREY THUR WILLIAM wnsHiNCTON <br />STAMP <br />Q <br />0 <br />�U) <br />U)11� <br />LULU <br />o <br />a <br />LU <br />0 <br />0 <br />N <br />W <br />Q <br />o <br />U) <br />o <br />c <br />0 <br />a <br />N <br />d <br />0 <br />d <br />ca <br />0 <br />d <br />E <br />t <br />M <br />�o <br />Q� <br />N <br />� N <br />a) co <br />a) (n <br />L <br />p) Q <br />A+ <br />W <br />> <br />o <br />w> ai <br />N <br />� <br />� <br />0 <br />w <br />z <br />U 0 <br />UJ <br />00 <br />J (n CF) <br />L <br />a n 0 Q <br />Q E w <br />o <br />Q <br />w ) z ai <br />z o (1) <br />l0w <br />w <br />O ii ( m <br />PROJECT #: 1827 <br />DRAWN BY: AT <br />CHECKED BY: ST <br />BLDG C - FLOOR 2 <br />SOUTH <br />w <br />Q <br />z <br />w <br />J <br />U_ <br />BLDG C - LEVEL 2 SOUTH <br />1/8" = 1'-0" <br />(p <br />BUILDING C �n A231 A <br />PERMIT SET 10/09/2020 <br />
The URL can be used to link to this page
Your browser does not support the video tag.