Everett Housing Authority JN 12080 <br /> May16, 2012 Page 7 <br /> The values given above are to be used to design only permanent foundation and retaining walls <br /> that are to be backfilled, such as conventional walls constructed of reinforced concrete or masonry. <br /> It is not appropriate to use the above earth pressures and soil unit weight to back-calculate soil <br /> strength parameters for design of other types of retaining walls, such as soldier pile, reinforced <br /> earth, modular or soil nail walls. We can assist with design of these types of walls, if desired. The <br /> passive pressure given is appropriate only for a shear key poured directly against undisturbed <br /> native soil, or for the depth of level, compact fill placed in front of a retaining or foundation wall. <br /> The values for friction and passive resistance are ultimate values and do not include a safety <br /> factor. We recommend a safety factor of at least 1.5 for overturning and sliding,when using the <br /> above values to design the walls. Restrained wall soil parameters should be utilized for a distance <br /> of 1:5 times the wall height from corners or bends in the walls. This is intended to reduce the <br /> amount of cracking that can occur where a wall is restrained by a corner. <br /> The design values given above do not include the effects of any hydrostatic pressures behind the <br /> walls and assume that no surcharges, such as those caused by slopes, vehicles, or adjacent <br /> foundations will be exerted on the walls. If these conditions exist, those pressures should be added <br /> to the above lateral soil pressures. Where sloping backfill is desired behind the walls, we will need <br /> to be given the wall dimensions and the slope of the backfill in order to provide the appropriate <br /> design earth pressures. The surcharge due to traffic loads behind a wall can typically be <br /> accounted for by adding a uniform pressure equal to 2 feet multiplied by the above active fluid <br /> density. Heavy construction equipment should not be operated behind retaining and foundation <br /> walls within a distance equal to the height of a wall, unless the walls are designed for the additional <br /> lateral pressures resulting from the equipment. <br /> Wall Pressures Due to Seismic Forces <br /> The surcharge wall loads that could be imposed by the design earthquake can be modeled <br /> by adding a uniform lateral pressure to the above-recommended active pressure. The <br /> recommended surcharge pressure is 8H pounds per square foot (psf), where H is the <br /> design retention height of the wall. Using this increased pressure, the safety factor against <br /> sliding and overturning can be reduced to 1.2 for the seismic analysis. <br /> Retaining Wall Backfill and Waterproofing <br /> Backfill placed behind retaining or foundation walls should be coarse, free-draining <br /> structural fill containing no organics. This backfill should contain no more than 5 percent silt <br /> or clay particles and have no gravel greater than 4 inches in diameter. The percentage of • <br /> particles passing the No. 4 sieve should be between 25 and 70 percent. The later section <br /> entitled Drainage Considerations should also be reviewed for recommendations related to <br /> subsurface drainage behind foundation and retaining walls. <br /> The purpose of these backfill requirements is to ensure that the design criteria for a <br /> retaining wall are not exceeded because of a build-up of hydrostatic pressure behind the <br /> wall. The top 12 to 18 inches of the backfill should consist of a compacted, relatively <br /> impermeable soil or topsoil, or the surface should be paved. The ground surface must also <br /> slope away from backfilled walls to reduce the potential for surface water to percolate into <br /> the backfill. <br /> It is critical that the wall backfill be placed in lifts and be properly compacted, in order for the <br /> above-recommended design earth pressures to be appropriate. The wall design criteria <br /> GEOTECH CONSULTANTS,INC. <br />