<br /> Fm'I SE1/4 SW1/4 SEC.34,TWP.29 N., RGE.4 E.,W.M. N N
<br /> m GENERAL PLANTING NOTES
<br /> m_n 1. COMMON OPEN SPACE AND PERIMETER LANDSCAPE AREAS WILL REQUIRE A PERMANENT AUTOMATIC
<br /> :5,< OPEN SPACE IRRIGATION SYSTEM. IRRIGATION PLAN WILL BE PROVIDED AS PART OF FINAL DESIGN.
<br /> CD Ln CALCULATIONS 2. REFER TO CIVIL PLANS FOR NEW UTILITY WORK. CONTRACTOR RESPONSIBLE FOR PATCHING AND
<br /> a c ,- REPAIRING ALL EXISTING LANDSCAPE AREAS DISTURBED BY CONSTRUCTION UNDER THIS CONTRACT.
<br /> m ,
<br /> Area per Area ,' 3. GRADING SHALL BE ACCEPTED PRIOR TO PLANT INSTALLATION. FINISHED GRADE FOR NEW PLANTING
<br /> Unit #of r AREAS SHALL ALLOW FOR TOPSOIL AND BARK MULCH AND 1-INCH CLEAR TO TOP OF CURB OR
<br /> Size Units Unit Required - - � � •••" SIDEWALK.
<br /> (Sq.Ft.) (Sq.Ft.) ....,, 1p1+00..
<br /> • -� ���— 4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVING AND HAULING ALL EXTRA DEBRIS AND
<br /> \o
<br /> 2+ 25 100 2.500 EXCESS SOIL GENERATED BY THIS PROJECT. o_ � � -__ � _--
<br /> A PRIVATE OR COMMON 2,500 °� \ PLANTING. FERTILIZING AND WARRANTY m
<br /> o OPEN SPACE REQUIRED !- j n 3 : m m
<br /> ,�
<br /> ro
<br /> '/ �? 5. ALL PLANT SIZES NOTED FOR HEIGHT, SPREAD AND CALIPER ARE MINIMUM REQUIREMENTS. PER EMC ¢ N f° N o
<br /> ro PROVIDED OPEN SPACE --' t \-', A CO REQUIRED PLANTING 0 PERIMETERS SHALL MINIMUM
<br /> REQUIREMENTS.
<br /> I k N
<br /> _ ALL DE QUIR D LA TING ALONG PROPERTY PE ERS ET THE MINIMUM _ Ja
<br /> TRACT 999-OS& 4,966 �0 _ APPROWA ,, ,J �o -' INSTALLATION SIZE STANDARDS, EVERGREEN TREES SHALL BE A MINIMUM OF 6FT AT TIME OF m F
<br /> SACT 999-OS N,6? BUS STOP . . ,� PLANTING, DECIDUOUS TREE 2" CALIPER, AND SHRUBS 2 GAL / 18-INCHES HIGH MIN. c> w !a+
<br /> LOCATION s No fi
<br /> 6 0 �n 0 w
<br /> • s: . ALL PLANTS SHALL CONFORM TO AMERICAN ASSOCIATION OF NURSERYMAN (AAN) GRADES AND o
<br /> _, .. STANDARDS AS PUBLISHED IN THE MOST RECENT Z60.1 "AMERICAN STANDARD FOR NURSERY -
<br /> _ STOCK MANUAL TREE CALIPER SHALL BE MEASURED SIX INCHES ABOVE THE ROOT FLARE o Z
<br /> 3T MUKILTEO - "<' • 7. AREAS DISTURBED BY GRADING AND NOT SHOWN AS PLANTING / LAWN AREAS SHALL BE SEEDED. x Z N
<br /> WE •�; •s
<br /> 8. APPLY FERTILIZER TO ALL LAWN, GROUNDCOVER, SHRUB AND TREE PLANTING AREAS. FOLLOW M I, N
<br /> ' �' - '-� �•. MANUFACTURER'S RECOMMENDATIONS FOR FERTILIZER TYPE ( -P-K RATIO) FOR LAWN 0 RNAMENTAL
<br /> ' '° ° • SHRUBS, AND TREES. e M N
<br /> -.
<br /> 1216 SF 9. SO A OD LAWN WITH 1 CLEAR TO TOP $ _
<br /> TOPSOIL. COMPOST AND MULCH
<br /> s
<br /> 220 SF OFMCOURBSUSIDEWALKMOREOTHEROPAVEDMSURFATCESOP IL BARK, S & -E
<br /> 1220 SF 3 10.REFER TO PLANTING PREPARATION DETAIL FOR TOPSOIL AND COMPOST REQUIREMENTS. w B rn
<br /> 1220 SF 11 COMPOST SUPPLIED BY CEDAR GROVE, 877( ) 764 5748 OR APPROVED EQUAL\ 15205 SF -
<br /> 26663 SF
<br /> + W N
<br /> 1525 SF >12. TOPSOIL SHALL BE A 3-WAY (LOAM SOIL, PEAT AND COMPOST) SUPPLIED BY CEDAR GROVE, (877) �
<br /> O 1220 SF ', z 764-5748 OR APPROVED EQUAL.
<br /> 1221 SF w ri i�
<br /> / 9 i aQ. 2 E}--
<br /> `
<br /> 1296 SF ,•I s a 13.BARK MULCH SHALL BE HEMLOCK / FIR MEDIUM GRIND. F s
<br /> S 1465 SF -. ]] WA III ZT+� I a P�J e(iIApN
<br /> REDUCE ii
<br /> REFER TO SHEET w / ! i INTERNAL bm y rys�~
<br /> \ I L1.1-L1.2 FOR 3 WALKWAY TO ZSFo 833 EXP.B��\C'�
<br /> DETAILED 7.0' +4.0' = 11' PLANTING, SAFETY RAIL AND pQ'
<br /> `� \ \���-_ °' s° • 6 PLANTING PLANS 3.5-FEET. WALL SECTION. LANDSCAPE PLANTING EXCEEDS
<br /> ` o APPROVED AS THE TYPE III DENSITY FOR SHRUBS AND GROUND
<br /> NOTED BY SI/COE COVER
<br /> PLANNING DEPT. °
<br /> 12 1181 SF
<br /> \� ` +\ ' �. I • ., ' 1181 SF ° ZONE w 1:1 11 C PE 4' WALL AND U 00
<br /> i P
<br /> ` / o 14 1 181 SF I. ^-� j N INTERNAL WALL TREATMENT J
<br /> 15 1181 SF ° " 3 K = AY PLANTING J F Co
<br /> � 1241 SF � V) °D
<br /> 2,
<br /> x SEE SHEET L1.3 •< a.__1_.'.•. �. 42 HT. SAFETY RAILING Z W Q
<br /> FOR OPEN SPACE ' �=
<br /> U.1
<br /> (�
<br /> LU
<br /> > F
<br /> mI 5' WIDE TYPE III 17 1301 SF _ + /fp = irm O a w
<br /> PERIMETER LANDSCAPE 18 1301 SF
<br /> x PER EMC 19.35.060 3 TREES, SHRUBS„"'\\\\\\ w rn >
<br /> 1232 SF
<br /> 10' WIDE TYPE I AND GROUND j,?//jam/jam/% - MODULAR BLOCK WALL, (D W
<br /> PEReI ALL TREES PLANTED 1300 SF I PER EMC R19 35 060APE COVER/
<br /> �AA/AAA//AA//AA/�AA� BLOCK WALL FINISH Q U')
<br /> ADJACENT TO ACCESS DRIVE o 00 23 1301 SF //AA%��/%\/%�� SHRUBS, ND TREES OMI ND TTED DUEOCOVNFLIER ONLY,
<br /> TO BE LIMBED FOR A MINIMUM __ oT WITH
<br /> VERTICAL ROADWAY ZONE m + 1301 SF UNDERGROUND UTILITIES
<br /> •V j/�
<br /> CLEARANCE OF 13'AD TO \ \ \ 3
<br /> MEET FIRE CODE
<br /> WEST
<br /> S2 O21 MUKILTEO z
<br /> 1241 SF /A/ SIDEWALK PLANTER
<br /> 10' ....a. a .• .. ////// Q
<br /> 201181 SF 4 �. /\%j 15 BLVD W 1L
<br /> PROPERTY LINE 10 SF 1181 SF sa' / ��A,- ,•
<br /> ' I AR FENCE -12" DEPTH ROOT BARRIER W W MNEOF WALL TO SC
<br /> CATEN \ AA�V� A�VAAAAAAA o
<br /> `i NICE
<br /> UB 12 2 BY DEEP ROOT OR �; _VAA v-V�� Z
<br /> � APPROVED EQUAL. � � ' \ O % // / O Q
<br /> —MODULAR BLOCK WALL ° 1.,° I, �� ///V��
<br /> /S<O EXISTING 12' DIA. / /AA/AA/AAj m w
<br /> �a` a 'OF v STORM DRAIN PIPE, 36"
<br /> ONLY INSTALL GROUND p •i W f DEPTH %/A�//A�//A�/��//�'�� Q
<br /> COVER o I BELANTT BARRMIIER A \ X/ EXISTING\ REFER TO CIVIL PLANS ��i/ / //j- / SANITARY 2
<br /> BETWEEN ROOT SEWER, LU
<br /> �, AND TOP OF WALL < \ .r FOR RETAINING WALLS i\\/\�,^� O DEPTH 84"t 0
<br /> lye `3' r AND GRADING V/
<br /> z \ HT. SOLID CEDAR
<br /> r^ FENCE, INSTALLED
<br /> �F Z z zo 2. A NEAR PROPERTY LINE,
<br /> 2 oi, �S<o \ \ ZONE (SOUTH AND EAST I I 1 PROPOSED MUKILTEO BLVD FRONTAGE SECTION VERIFY SCALE
<br /> BAR IS ONE INCH ON DRAWING.
<br /> PROPERTY LINES) N 1 =5 0
<br /> d IF NOT ONE INCH ON THIS SHEET,
<br /> ADJUST SCALES ACCORDINGLY.
<br /> R-S
<br /> I
<br /> SCALE: DATE:
<br /> ES JUTE MAT(RATED FOR 2:1) 10' TYPE I PERIMETER AS SHOWN 9/6/22
<br /> DESIGNED BY: CHECKED BY:
<br /> ON SLOPES GREATER THAN LANDSCAPE PER EMC
<br /> 3:1 LANDSCAPE STAPLES 19.35.060 0 10 20 40 I KM ACR/KAG
<br /> � .% EVERY 24" HORIZ Scale In Feet L7 REFER TO SHEET .4 PACE PROJECT N0. 21586
<br /> 2 CALLYOU IG BEFS L1 .0
<br /> RE FOR PLANT SCHEDULE
<br /> F
<br /> G� � UNDERGROUND SENCE(USA) REV1122-001 SHEET