My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3618 W MUKILTEO BLVD 2022 SITE WORK FOR HARBORS EDGE TOWNHOMES Plans 2025-08-07
>
Address Records
>
W MUKILTEO BLVD
>
3618
>
SITE WORK FOR HARBORS EDGE TOWNHOMES
>
Plans
>
3618 W MUKILTEO BLVD 2022 SITE WORK FOR HARBORS EDGE TOWNHOMES Plans 2025-08-07
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/28/2025 11:27:14 AM
Creation date
7/28/2025 11:23:04 AM
Metadata
Fields
Template:
Address Document
Street Name
W MUKILTEO BLVD
Street Number
3618
Tenant Name
SITE WORK FOR HARBORS EDGE TOWNHOMES
Permit
PW2205-022
Year
2022
Notes
SITE WORK FOR HARBORS EDGE (ULS)
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
90
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SE1/4 SW1/4 SEC. 34,TWP.29 N., RGE.4 E.,W.M. - - - - - w <br /> M N\M\O N O Q <br /> *CONTRACTOR TO VERIFY *EXISTING GAS LINE \' _ <br /> DEPTH OF UTILITY PRIOR , <br /> TO CONSTRUCTION 1p1+� <br /> ST 19.14 LT) A \ <br /> WATER NOTES £ <br /> u WITH 1-8; VALVE <br /> % � N NEW M91N--C6NNECTION BY _ \ <br /> C -EVERETT PUBLIC WORK <br /> A. NO CONNECTION TO THE EXISTING MAINS WILL BE <br /> ALLOWED EXCEPT BY MEANS OF AN APPROVED BACKF STA 97+50.51 (17.93 LT) <br /> LOW _ +00 <br /> PREVENTION DEVICE PRIOR TO SATISFACTORY FLUSHING, HOT TAP WITH 1-8" GATE VALVE 100-�' <br /> TESTING, DISINFECTION, AND RECEIPT OF SATISFACTORY ON NEW MAIN CONNECTION BY %ui` Gj680� J- o <br /> BACTERIOLOGICAL TEST RESULTS. ,CITY OF EVERETT PUBLIC u/ N j6 ape•E W z wo a Q J <br /> B. CONNECTIONS TO AND TAPS ON EXISTING MAINS WILL EXISTING GAS LINE <br /> BE MADE BY THE PUBLIC WORKS DEPARTMENT AT THE o ` - sn " -• � F o F K k <br /> DEVELOPER'S EXPENSE. THE PUBLIC WORKS DEPARTMENT w w 3 m m <br /> SHALL BE GIVEN AT LEAST 5 BUSINESS DAYS NOTICE u ,- <br /> FOR EACH CONNECTION. THE PUBLIC WORKS DEPARTMENT 103 LF 8" DI�� r� a ¢ J '�' N g <br /> SHALL THEREAFTER DETERMINE THE DATE AND TIME AT / TEC BLVD- ss/ss o 00 w t N <br /> WHICH THE CONNECTION SHALL BE MADE. + MUKIL rp w a m <br /> C. ALL WORK AND MATERIALS MUST CONFORM TO CITY WE$T /ss • s' I d o 1 w w o: <br /> OF EVERETT STANDARDS. ss sue/ s i a U o o N a' <br /> D. A PRE CONSTRUCTION MEETING SHALL BE HELD WITH �� /sssv w <br /> THE CITY PRIOR TO THE START OF CONSTRUCTION. THE �� \ 1 _ ss - _ssa,. L o a o 0 <br /> CITY OF EVERETT PUBLIC WORKS CONSTRUCTION DIVISION / t- ss�' is1,. 340 1'7. -E-t<. F o wo <br /> MUST BE NOTIFIED AT LEAST 24 HOURS PRIOR TO \ \ EXI - / L N r F w U <br /> COMMENCEMENT OF CONSTRUCTION. \ __ *EXI ING 24" SS, ass s A o w o 0 o F <br /> E. THE DEVELOPER OR THE DEVELOPER'S AUTHORIZED _ sti---/ - L 1 3 > > M Of M N N <br /> AGENT SHALL NOTIFY THE PUBLIC WORKS DEPARTMENT OF _ \ EXI SD- - -9 <br /> A PERSON WHO CAN BE CONTACTED REGARDING PROBLEMS <br /> DURING CONSTRUCTION ON A 24 HOUR BASIS. m <br /> F. MAINTAIN A MINIMUM OF 10 FEET HORIZONTAL AND 18 O <br /> INCHES VERTICAL SEPARATION BETWEEN POTABLE AND ��J �� - ,�`°• s ,-''' \ 4 <br /> 5 m <br /> NON-POTABLE CONVEYANCE SYSTEMS. <br /> G. ALL CITY OF EVERETT VALVES SHALL BE OPERATED BY <br /> PUBLIC WORKS DEPARTMENT PERSONNEL ONLY. ALL 9\ © g W E o <br /> VALVES, <br /> NEW AND EXISTING, SHALL BE ACCESSIBLE AT ALL TIMES. \ ® N I y a@$ <br /> H. PROPOSED FIRE HYDRANTS WITHIN THE PRIVATE - 99 \ - <br /> DEVELOPMENT ARE PRIVATE AHS SHALL BE PAINTED WITH i \\ O9 STA 2 55.00 (8.3 RT) .�° SS 7 72 <br /> 8 PROPOSED 1-8" D TEE (MJ}- - F & `m M ;EO <br /> TWO COATS OF HIGH GLOSS "SAFETY RED". THE PORT \ 'S d <br /> 5 \ VAULT 3-8" DI GATE VALVE (FLxMJ) '' -�-o 55 m a¢ f <br /> CAPS SHALL BE PAINTED BLACK. R P 1 ° <br /> wp'tER.j 5' 1G 1-THRU BLOCK 1 - £ �� .a 21+00 'm n <br /> SEME STA 31+13.28 S N <br /> \� N:350516.48 Z m <br /> E:1285043t56--" <br /> g <br /> -B`DI 45' BEND (MJ) <br /> 1-THRUST BLOCK <br /> 23 LF 8" DI <br /> �42 And "C;Reav o <br /> 144 STA 26+46. 9 (8.01 RT) 31257 <br /> \, 46 % % �? - �6` 11 FF�isTER��O-•1 <br /> vo <br /> 1. a <br /> STA 31+36. 4 - N 77'2 '09., I 4.° 13 i 3 I PROP 25' <br /> SEWER <br /> N:350504.09 E ( ) 14 N WATER & <br /> \€1285068.67 STA 25 81.60 7.57 RT z <br /> A-8" DI 45- BE (MJ) 15 LF 12" I 1-8" DI 45' BEND ( J) 15 % tO EASEMENT <br /> 1-THRUST BLOCK CASING W/THRU T BLOCK U.. _ % <br /> P \ <br /> 00 <br /> 48 LF 8" DI 19 LF DI �k ., %. S �I J <br /> STA 31+84.23 I 16 <br /> I, % N I J F o <br /> N:350512.65 \\ <br /> E:1285116.10 -1 :E y 00 <br /> 1-8" DI 45- BEND MJ 3 7 LF 8" D 3 F Z <br /> "g✓`7 165 ............................................................................................................ 165 1 THRUST ( ) ,� .70 \ In y < <br /> LIJ <br /> '^ 160 ..............................:...........................................STA:31+82.74 .._... .._......?B160 25 LF 8 DI I c �% % %1 3 I F <br /> STA:31+84. \� BLOCK <br /> HORIZONTAL \\ 25 <br /> gl STA:31+36.07 .,I - % 24 I Q Q w <br /> IE:145.99 STA 25+47.26 (4.78 RT) + <br /> x HORIZONTAL BEND 2" S 1 DI 4' BEND ( ) I N \ % / '' O = _ Of <br /> 155 '..............................................EXISTING GRADE..........._..CASING "... .. ... ... ....11 55 D W/THRUSTSBLOCK \ I N W M W <br /> PROP _ MJ 1 - 23 <br /> $� ® WATER OL StA:31+67.74 ON CON OP RD 97 LF 8 DI <br /> 150 .......................................HORIZONTAL BEND ......_. ...... IE:143.20. 150 ND 21 156 � I N <br /> CONNECTION <br /> x EX.-12'" SID / - 20 s ' <br /> 145 -......0,568'-CLEARANCE.......... .FINISHED.GRADE. .o z.... ..... .................. - 145 19 <br /> i <br /> U' I <br /> ® WATER n o M a1 <br /> ' -EX• GAS MAIN: vim :8 DI WA TYP oz .�.�...0 . .'n 5 % ' ^� <br /> 140 ..........-'WEST....... ...................... o.Z ................ .. ........ 140 PROP WATER �ti <br /> 1 I <br /> ro.s c� W <br /> MUKI WEST <br /> BLV <br /> I <br /> ' 135 :............�._.:a._... ... f-r.'-- ..:............... .............. ...._.... STA:31+89.07 35 <br /> I 5 W <br /> 130 ..._.. ...N ....... .' ..................STA:30+90.10 ..... ..._.....VERTICAL 1BEND 30 1.25' 1 I \ _ _s,a SS D r l7 d ZO <br /> I <br /> W/THRUST BLOCK \ �' % 0 N <br /> `7 ELEV:134.38 1 W W 0- <br /> n 'o x 1-8" DI 11.25' S <br /> J <br /> 125 -X ��SSI ���-,dw VERTICAL BEND ������ ������ 1 24 ''' �STA:31+65.54������'': 125 STA 24+48.96 (4.34 RT) � - � � LIJ <br /> 'EX. 8" SS W/THRUSi BLOCK :STA:31 2.96 ELEV:142.90 24+00 55 -� " E W z <br /> : ELEV:142.90 � \ / . 4- I �Z <br /> 120 ............-EX:-24".SS .. .... .........1-8" DI 11.25- ...1-8" DI 11.25. ...... 120 � '� ��1010 m Q <br /> PROP 12" SD STA:30+82.02 :VERTICAL BEND VERTICAL BEND : \ I T 0/ 22 IY ?�J a . ...........SERVICE-'.1TANCE 830i56'625' VERTICAL BEND ........../THRUST BLOCK /T 1 % / /per �A v d <br /> �n W HRUST BLOCK / v <br /> WATER <br /> i 115 ... 1-8" DI 13 115 2 <br /> n :0.76' CLEARANCE VERTICAL BEND W/THRUST BLOCK <br /> W/THRUST BLOCK......:........................................................: 110 / N <br /> A g 110 :*CONTRACTOR'TO'VERIFY-.......... . <br /> i DEPTH OF UTILITY PRIOR: A / <br /> 105 TO CONSTRUCTION <br /> VERIFY SCALE <br /> tia n aD N M Om m N aD M m w N 4 M N< N aD n n / BAR IS ONE INCH ON ORIGINAL DFAWING. <br /> N m m NIq WN1 mN N M Ma! On IN nta nN / 0-1- <br /> o M M M a o N CO 0 0 M N r n n^6 a0 O N M N Permit#: PW2205-022 0 i D 2D 40 IF NOT ONE INCH ON THIS SHEET, <br /> M M M MM MM asa1 712 NN NN HOR Z. <br /> a Site Address: 3618 W Mukilteo Blvd ADJUST SCALES ACCORDINGLY. <br /> Owner: Sage Homes Northwest LLC L City of Everett Permit Review j Scale In Feet SCALE: DATE: <br /> Application Date: 05/24/2022 EVERETT Status:Revisions Approved 0 5 10 20 AS SHOWN 07/13/2023 <br /> r 30+00 31+00 32+00 32+14.75 Description: Site Work for Harbor's Edge(ULS) -'•°'- 07/17/2023 9:46:34 AM VERT. DESIGNED BY: CHECKED BY: <br /> n Scale In Feet KDS/TB ACR/RB <br /> d WATER PROFILE -TRACT 999 Review Status: Approved-Revision after Issuance PACE PROJECT NO. 21586 <br /> ..emu Review Date: 07/17/2023 CALL BEFORE <br /> F A�01 <br /> YOU DIG UNDERGROUND WA�) REV1122-001 SHEET <br />
The URL can be used to link to this page
Your browser does not support the video tag.