Laserfiche WebLink
m <br /> m SE1/4 SW1/4 SEC.34,TWP.29 N., RGE.4 E.,W.M. <br /> W <br /> m�i COMPONENT LEGEND <br /> 1" BRASS OR COPPER THROUGH DOUBLE CHECK VALVE <br /> m0 ASSEMBLY, PRV (IF REQUIRED) BLOW-DOWN, MASTER MANUFACTURER / DESCRIPTION <br /> < VALVE, AND FLOW SENSOR SYMBOL <br /> CD o 1" IRRIGATION SEE DCVA DETAIL 1 2 AUTOMATIC CONTROL VALVES RAIN BIRD PEB SERIES FOR SPRAY ZONES OR <br /> `r �' WATER METER 1" PRESSURE -�' XCZ-150-COM FOR DRIP ZONES. FINAL SIZING TO BE NOTED BY CONTRACTOR. <br /> a< REDUCER VALVE (IF MIN. DISTANCE REQ. BY MANUFACTURER L2.1 L2.1 <br /> (D REQUIRED) FLOW SENSOR _ ------- IRRIGATION MAIN LINE PIPING 1-1/2" SCHEDULE 40 PVC. SUGGESTED LOCATIONS, <br /> O /D 1-1/2" SCH. 40 PVC ,-1 -_ _ 2 CONTRACTOR TO ADJUST AS NEEDED <br /> .+ <br /> _ 3 2 LATERAL PIPING CLASS 200PVC, CONTRACTOR TO SIZE, 3/4" MIN. NOTSI <br /> PRV ac � -__„ �1 �,_- 1p1+00 _, -_- SHOWN. CONTRACTOR TO SIZE BASED ON REQUIRED FLOW <br /> i (_4 SLEEVING - SCHEDULE 40 PVC <br /> j BRASS / PVC COUPLER �� _ �- \ \ L2 2 SUGGESTED LOCATIONS SHOWN, CONTRACTOR TO SIZE, 2X SUM OF INTERIOR W <br /> 1" SYSTEM BLOW DOWN PIPE SIZES MIN. ¢ a a <br /> 1" BRASS GATE VALVE - 1" MASTER VALVE NORMALLY CLOSED / - WIRE— k _k <br /> p ( ) RPBA required if \ WIRE SLEEVE 2-INCH SCHEDULE 40 PVC (NOT SHOWN) E - <br /> N SHUT-OFF q m m <br /> 0 1" DOUBLE CHECK VALVE ASSEMBLY below grade - QUICK COUPLER VALVE, 1" RAIN BIRD 44LRC W/ 44K COUPLER KEY SH-1 HOSE � m <br /> rNj couplings used. 10D+00 �' ,,'' L2. SWIVEL AND 2049 LID KEY; SEE PLANS FOR LOCATIONS, CONNECT TO MAINLINE, ¢ rn o <br /> NNECTIloiaso -- J NEW 1" IRRIGATION METER, SEE UTILITY PLAN FOR LOCATION j FF <br /> E W <br /> ai <br /> NTS 2 O GATE - ISOLATION VALVE, MATCH MAINLINE SIZE (NOT SHOWN) N <br /> 1 3 IRRIGATION POINT OF CONNECTION 0 <br /> POC - IRRIGATION SHUT-OFF VALVE RPBA required if <br /> Gi 99-qQ ___/ sn/` - DOUBLE CHECK VALVE ASSEMBLY - FEBCO 1" 850U below grade wo Z <br /> sa - QUICK COUPLING VALVE ouplings u 0 o r, <br /> a/ UI(ILTEOBLVD /�'� °,'' / 1-1/2" IRR. - PRV 1" WATTS 600 IF REQUIRED 0 0 0 r <br /> y1lEST M _ �'•� MAINLINE IN 6" - MASTER VALVE RAIN BIRD 1.5" GB SERIES M M N N <br /> c sed <br /> �/ /sn °.A." :.1.. .'•I •� ' LEEVE TY P. 1 IRRIGATION CONTROLLER LOCATION <br /> S <br /> C RAIN BIRD ESP LXME2P WITH FLOW CONTROL MODULE e n N <br /> IRRIGATION POC, L2.2 ❑ 24 STATION CONTROLLER (ADDITIONAL MODULES REQUIRED) <br /> SEE DETAIL THIS IN LXMMSS STAINLESS STEEL CABINET <br /> PROVIDE 6-INCH S- ".` a HEET 2 <br /> SLEEVE THROUGH -' �S9' O CONTROLLER FOR SYSTEM TO BE CONNECTED TO A WEATHER SENSOR / SHUT Ein <br /> OR UNDER ALL' -'' OFF MOUNTED ON CABINET OR TO NEAREST LIGHT POLE. CONTRACTOR TO a b <br /> WALLS, n s O2 1216 SF . : NEW 1" IRRIGATION PROVIDE 120V, 15AMP SERVICE TO ENCLOSURE. g - <br /> _ 14 0 1220 SF METER, REFER TO z CA_ O CIVIL PLANS FOR PIPE SIZING CHART a <br /> \ .., e_. - e ..a•. O 4 1220 SF ; INSTALLATION d�� o, <br /> 2 <br /> _e- IRR LATERAL IN THE CONTRACTOR SHALL SIZE THE PIPE USING THE FOLLOWING a <br /> 1220 S REQUIREMENTS. ¢¢- j <br /> 3" SLEEVE, TYP. ®g CHART. LAWN, SHRUB PLANTING AREAS, AND DRIP IRRIGATION w �' <br /> \ 8 O 1525 SF (DRIP ZONES) AREAS SHALL BE PLACED ON SEPARATE ZONES / VALVES. FLOW T .5 26663 g � <br /> \ - O 1525 SF + FOR EACH ZONE /VALVE SHALL NOT EXCEED 20 GPM, QQ 33 <br /> 1220 SF <br /> O 1221 SF / 3 2 IN THE HYDRAULIC DESIGN AND PIPE SIZING, <br /> 10 1296 SF DO NOT EXCEED THE FOLLOWING G.P.M. OF <br /> 9 WATER USAGE PER SCHEDULED PIPE SIZE. pF W'Asy� <br /> 1465 SF 2T+00 - 4 FLOW PIPE SIZE Pp,,ep1AN h'9��'T <br /> 4966 / p <br /> IRR LATERAL IN W -1/2' IRR. � dd�11b13 2 <br /> (GPM) (CLASS 200 PVC) <br /> 3" SLEEVE, TYP. AINLINE IN <br /> 13 (DRIP ZONES) / / / / / SLEEVE, 1 -e 3/4" <br /> W � P. 8- 14 1" rys\r- <br /> 12 14-24 1 1/4" ZSF� es3 EXPeI'G��� <br /> / © 24-30 1 1/2" <.gNoscA� <br /> CO TROLLER LOCATION, <br /> \ / i C TRACTOR TO PROVIDE <br /> 1-1/2" IRR. W / PO ER 120V/15A <br /> MAINLINE IN IRRIGATION SCHEDULE <br /> 6" SLEEVE, / ' <br /> TYP IRR LATERAL IN"81 SF N, SYMBOL MANUFACTURER / DESCRIPTION <br /> 3" SLEEVE, T... ZONE <br /> N E a0 <br /> e 13 g INSTALL 12" POP-UPS IN ALL <br /> O O (DRIP ZONES) RAIN BIRD 1800-SAM-PRS TREE SHRUB AND GROUNDCOVER U <br /> �. 14 1 181 F p c L2.2 SPRAY OR ROTOR ZONES AREAS, INSTALL 6" POP-UPS IN J w <br /> IRR. ( 15 co <br /> 1181 SF 3 R-S ALL LAWN AREAS <br /> MAINLINE IN I J N <br /> 6" SLEEVE, I I 1241 SF , 'sue° RAIN BIRD DRIPLINE rn <br /> \ TYP I L2• XFCV-09-12 Z al a <br /> \ I I 16 / W w <br /> PLACE TOP AND BOTTOM DRIP W F. <br /> 17 1301 SF + SYSTEMS ON SEPARATE Q Q Lu <br /> to SF IRRIGATION ZONES. IRRIGATION VALVE SCHEDULE 2 F w <br /> \ I 282 SF 11 <br /> 3 VALVE N0. M 1 2 3 4 5 6 7 6 9 10 11 12 13 14 15 16 W 0) 0> <br /> 5 ,11 <br /> ® 1300 SF GPM Q ED <br /> ZONE 3013 SF 1301 SF VALVE SIZE 1.5' <br /> ' m 5 EST. PR./HR <br /> N IRR LATERAL IN <br /> 3" SLEEVE, TYP. <br /> ). 21 24 <br /> 10 1241 SF (DRIP ZONES) 6 VALVE NO. 17 18 19 20 21 22 23 24 <br /> GPM W <br /> 1181 SF ��?-� <br /> 19 1181 SF .n / / VALVE SIZE 0 Z <br /> S1180 SF / / EST. PR./HR W d <br /> 9 N o <br /> /W 23+00 0 ~ <br /> C) Q <br /> `2 \ PLACE TOP AND BOTTOM DRIP / VALVE <br /> g SYSTEMS ON SEPARATE I / / SIZE GPM <br /> IRRIGATION ZONES. I 1-1/2" IR _ <br /> io MAIN PLACE TOP AND BOTTOM DRIP 4 CONTRACTOR TO SIZE EACH ZONE BASED ON FLOW AND COVERAGE TYPE. EACH ZONE SHALL BE <br /> LEEVE, SYSTEMS ON SEPARATE LABELED ON THE IRRIGATION AS-BUILT SIMILAR TO THE EXAMPLE ABOVE. <br /> TYP. IRRIGATION ZONES. <br /> LAWN ZONES SHALL BE SEPARATE FROM TREE SHRUB AND GROUNDCOVER AREAS. <br /> VERIFY iCALE <br /> BAR IS <br /> z <br /> �F <br /> I ONE INCH ON ORIGINAL DRAWING. <br /> R 0 <br /> �� ZONE IF NOT ONE INCH ON THIS SHEET, <br /> oa ? ADJUST SCALES ACCORDINGLY. <br /> RCS' IRRIGATION NOTES AS SHOWN 9/26SCALE: I E:REFER TO SHEET L2.1-L2.2 FOR IRRIGATION NO ES <br /> AND DETAILS. DESIGNED BY: CHECKED BY: <br /> IRRIGATION SYSTEM IS DIAGRAMMATIC, LOCATE 0 10 20 40 KDS ACR/KAG <br /> IRRIGATION MAIN AND LATERALS WITHIN LANDSCAPE HORIZ. PACE PROJECT NO. 21586 <br /> ,�.. BEDS WHEN POSSIBLE, SLEEVING IS REQUIRED CALL BEFORE Scale In Feet <br /> W � UNDER ALL PAVED SURFACING AND WALLS. YOU D G 811 <br /> `J'wi v�Wiz UNDERGROUND SENCE(USA) REV1122-001 SHEET �� 0 <br /> ¢uS�x <br />