I OPERATION AND <br /> CONTECH® <br /> I ENGINEERED SOLUTIONS MAINTENANCE <br /> 1 CatchBasin StormFilterT" <br /> Maintenance Guidelines Mosquito Abatement <br /> Maintenance procedures for typical catch basins can be applied In certain areas of the United States, mosquito abatement is <br /> to the CatchBasin StormFilter(CBSF). The filter cartridges desirable to reduce the incidence of vectors. <br /> contained in the CBSF are easily removed and replaced during <br /> I <br /> maintenance activities according to the following guidelines. In BMPs with standing water,which could provide mosquito <br /> breeding habitat, certain abatement measures can be taken. <br /> 1. Establish a safe working area as per typical catch basin <br /> service activity. 1. Periodic observation of the standing water to determine if <br /> I the facility is harboring mosquito larvae. <br /> 2. Remove steel grate and diamond plate cover (weight 100 <br /> lbs. each). 2. Regular catch basin maintenance. <br /> 3. Turn cartridge(s) counter-clockwise to disconnect from pipe 3. Use of larvicides containing Bacillus thuringiensis israelensis <br /> Imanifold. (BTI). BTI is a bacterium toxic to mosquito and black fly <br /> larvae. <br /> 4. Remove 4"center cap from cartridge and replace with <br /> I lifting cap.5. Remove cartridge(s) from catch basin by hand or with vactor In some cases,the presence of petroleum hydrocarbons may <br /> interrupt the mosquito growth cycle. <br /> truck boom. <br /> 6. Remove accumulated sediment via vactor truck (min.I <br /> Using Larvicides in the CatchBasin StormFilter <br /> clearance 13"x 24"). Larvicides should be used according to manufacturer's <br /> recommendations. <br /> 7. Remove accumulated sediment from cartridge bay. (min. <br /> I clearance 9.25"x 1 1"). Two widely available products are Mosquito Dunks and <br /> Summit B.t.i. Briquets. For more information,visit http://www. <br /> 8. Rinse interior of both bays and vactor remaining water and summitchemical.com/mos ctrl/d efault.htm. <br /> sediment. — <br /> I The larvicide must be in contact with the permanent pool. The <br /> 9. Install fresh cartridges) threading clockwise to pipe larvicide should also be fastened to the CatchBasin StormFilter <br /> manifold. by string or wire to prevent displacement by high flows. A <br /> 10. Replace cover and grate.1 <br /> magnet can be used with a steel catch basin. <br /> 11. Return original cartridges to Contech for cleaning. For more information on mosquito abatement in stormwater <br /> Media may be removed from the filter cartridges using the BMPs, refer to the following: http://www.ucmrp.ucdavis.edu/ <br /> vactor truck before the cartridges are removed from the catchI <br /> publications/managingmosquitoesstormwater8125.pdf <br /> basin structure. Empty cartridges can be easily removed from <br /> the catch basin structure by hand. Empty cartridges should be <br /> Ireassembled and returned to Contech as appropriate. <br /> Materials required include a lifting cap,vactor truck and <br /> fresh filter cartridges. Contact Contech for specifications and <br /> 111 availability of the lifting cap. The vactor truck must be equipped <br /> with a hose capable of reaching areas of restricted clearance. <br /> the owner may refresh spent cartridges. Refreshed cartridges are <br /> also available from Contech on an exchange basis. Contact the <br /> maintenance department of Contech at 503-258-3157 for more <br /> information. <br /> IMaintenance is estimated at 26 minutes of site time. For units <br /> with more than one cartridge, add approximately 5 minutes for <br /> each additional cartridge. Add travel time as required. <br /> IP Page 2 <br /> URBANGREENT" :�,=' <br /> www.ContechES.com/stornnwater <br /> Stormwater Solutions from Contech' % 800-338-1122 <br /> ©2013 Contech Engineered Solutions <br />