Laserfiche WebLink
II0.1005 93 63 67 Pass <br /> 0.1019 91 61 67 Pass <br /> 0.1034 87 60 68 Pass <br /> II <br /> 0.1048 87 59 67 Pass <br /> 0.1062 87 56 64 Pass <br /> 0.1076 84 55 65 Pass <br /> 0.1091 82 55 67 Pass <br /> 1 0.1105 82 54 65 Pass <br /> 0.1119 80 53 66 Pass <br /> 0.1133 77 53 68 Pass <br /> 0.1147 74 53 71 Pass <br /> II0.1162 74 51 68 Pass <br /> 0.1176 70 51 72 Pass <br /> 0.1190 67 51 76 Pass <br /> 0.1204 67 50 74 Pass <br /> 1 0.1219 64 50 78 Pass <br /> 0.1233 62 49 79 Pass <br /> 0.1247 62 49 79 Pass <br /> 0.1261 60 46 76 Pass <br /> 1 0.1275 57 45 78 Pass <br /> 0.1290 55 44 80 Pass <br /> 0.1304 55 43 78 Pass <br /> 0.1318 53 43 81 Pass <br /> 0.1332 52 42 80 Pass <br /> II <br /> 0.1347 51 42 82 Pass <br /> 0.1361 51 41 80 Pass <br /> 0.1375 51 41 80 Pass <br /> 0.1389 50 41 82 Pass <br /> II 0.1404 48 41 85 Pass <br /> 0.1418 48 40 83 Pass <br /> 0.1432 48 40 83 Pass <br /> 0.1446 48 40 83 Pass <br /> II0.1460 45 40 88 Pass <br /> 0.1475 45 40 88 Pass <br /> 0.1489 45 40 88 Pass <br /> 0.1503 45 39 86 Pass • <br /> 1 0.1517 45 39 86 Pass <br /> 0.1532 41 39 95 Pass <br /> 0.1546 41 39 95 Pass <br /> 0.1560 41 38 92 Pass <br /> 1 0.1574 41 38 92 Pass <br /> 0.1588 40 36 90 Pass <br /> 0.1603 39 36 92 Pass <br /> 0.1617 39 36 92 Pass <br /> I0.1631 38 36 94 Pass <br /> 0.1645 38 36 94 Pass <br /> 0.1660 37 36 97 Pass <br /> 0.1674 35 35 100 Pass <br /> I0.1688 35 34 97 Pass <br /> 0.1702 35 34 97 Pass <br /> Water Quality BMP Flow and Volume for BOO 1. <br /> II <br /> On-line facility volume: 0.0854 acre-feet <br /> On-line facility target flow: 0.01 cfs. <br /> I <br /> Adjusted for 15 min: 0.128 cfs. <br /> Off-line facility target flow: 0.0656 cfs. <br /> Adjusted for 15 min: 0.073 cfs. <br /> IIThis program and accompanying documentation is provided 'as-is' without warranty of any kind. The entire risk regarding the <br /> performance and results of this program is assumed by the user. Clear Creek Solutions and the Washington State Department of <br /> Ecology disclaims all warranties, either expressed or implied, including but not limited to implied warranties of program and <br /> accompanying documentation. In no event shall Clear Creek Solutions and/or the Washington State Department of Ecology be <br /> liable for any damages whatsoever (including without limitation to damages for loss of business profits, loss of business <br /> IIinformation, business interruption, and the like) arising out of the use of, or inability to use this program even if Clear <br /> Creek Solutions or the Washington State Department of Ecology has been advised of the possibility of such damages. <br /> I <br /> I <br />