2631 WALNUT ST JACKSONS 2025-07-28
>
Address Records
>
WALNUT ST
>
2631
>
JACKSONS
>
2631 WALNUT ST JACKSONS 2025-07-28
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/28/2025 1:58:05 PM
Creation date
7/28/2025 1:55:02 PM
Metadata
Fields
Template:
Address Document
Street Name
WALNUT ST
Street Number
2631
Tenant Name
JACKSONS
Notes
STORMWATER SITE PLAN
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
178
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1 <br /> Table 4.10 <br /> Geotextile Standards <br /> Polymeric Mesh AOS 0.60 mm maximum for slit film wovens(#30 sieve). 0.30 <br /> (ASTM D4751) mm maximum for all other geotextile types(#50 sieve). <br /> 0.15 mm minimum for all fabric types(#100 sieve). <br /> ' Water Permittivity 0.02 sec'minimum <br /> (ASTM D4491) <br /> Grab Tensile Strength 180 lbs.Minimum for extra strength fabric. <br /> (ASTM D4632) 100 lbs minimum for standard strength fabric. <br /> Grab Tensile Strength 30%maximum <br /> ' (ASTM D4632) <br /> Ultraviolet Resistance 70%minimum <br /> (ASTM D4355) <br /> • Standard strength fabrics shall be supported with wire mesh, chicken <br /> wire, 2-inch x 2-inch wire, safety fence, or jute mesh to increase the <br /> ' strength of the fabric. Silt fence materials are available that have <br /> synthetic mesh backing attached. <br /> • Filter fabric material shall contain ultraviolet ray inhibitors and <br /> ' stabilizers to provide a minimum of six months of expected usable <br /> construction life at a temperature range of 0°F.to 120°F. <br /> • 100 percent biodegradable silt fence is available that is strong, long <br /> ' lasting,and can be left in place after the project is completed,if <br /> permitt el regulations. <br /> • Standarded Notesby forcal construction plans and specifications follow. Refer <br /> to Figure 4.19 for standard silt fence details. <br /> The contractor shall install and maintain temporary silt fences at the <br /> ' locations shown in the Plans. The silt fences shall be constructed in <br /> the areas of clearing,grading, or drainage prior to starting those <br /> activities. A silt fence shall not be considered temporary if the silt <br /> fence must function beyond the life of the contract. The silt fence <br /> shall prevent soil carried by runoff water from going beneath,through, <br /> or over the top of the silt fence,but shall allow the water to pass <br /> through the fence. <br /> The minimum height of the top of silt fence shall be 2 feet and the <br /> maximum height shall be 2Y2 feet above the original ground surface. <br /> The geotextile shall be sewn together at the point of manufacture, or at <br /> ' an approved location as determined by the Engineer,to form geotextile <br /> lengths as required. All sewn seams shall be located at a support post. <br /> Alternatively,two sections of silt fence can be overlapped,provided <br /> the Contractor can demonstrate,to the satisfaction of the Engineer,that <br /> the overlap is long enough and that the adjacent fence sections are <br /> close enough together to prevent silt laden water from escaping <br /> ' through the fence at the overlap. <br /> February 2005 Volume II—Construction Stormwater Pollution Prevention 4-95 <br />