Laserfiche WebLink
EXTERIOR DOOR, AS <br />SCHEDULED <br />TURN MEMBRANE UP JAMBS - <br />TYPICAL w/ PRE -MANUFACTURED <br />BOOTS OR SIM. <br />PEDESTAL <br />PAVER 24 GA. PRE -FINISHED SM SILL PAN - <br />SYSTEM <br />FLAT CLOSURE PLATE FOR PAVER EXTEND LEG w/ HEMMED DRIP BELOW <br />EDGE TERMINATION (WELDED AND T.O. PAVER, TYP. <br />POWDERCOATED AS PART OF THE <br />RAILING SYSTEM) ALUMINUM THRESHOLD, TYP. <br />STAINLESS STEEL CLAMPING <br />RING AND SEALANT <br />MANUF. TYPICAL BOOT <br />M <br />ROOF ASSEMBLY, AS SCHEDULED <br />FSINGLE -PLY MEMBRANE AS <br />SCHEDULED <br />GUARDRAIL/ PAVER EDGE, TYP <br />SCALE:NTS <br />PENTHOUSE DOOR THRESHOLD, TYP. <br />SCALE:NTS <br />PIPE/TUBE PENETRATION - PREP SUBSTRATE PER <br />MANUF., AS REQUIRED <br />CONTINUOUS SEALANT @ GUMLIP <br />ABOVE CLASP <br />STAINLESS STEEL CLASP <br />a <br />Z PRE -MANUFACTURED BOOT FLASHING <br />co <br />HEAT WELD, TYP. <br />F— VAPOR BARRIER <br />PIPE PENETRATION, TYP <br />SCALE:NTS <br />SINGLE -PLY ROOF MEMBRANE, WELD <br />TO CLAD -METAL GRAVEL STOP <br />r— HEAT WELD <br />SAM o/ FLASHING <br />24 GA. PRE -FINISHED <br />SM FLASHING w/ <br />HEMMED DRIP <br />TRIM, AS SCHEDULED <br />LASHING TAP o/ HEAD <br />FLANGE <br />BED HEAD FLANGE IN <br />CONT. SEALANT <br />HIGH EAVE @ LOUNGE <br />SCALE:NTS <br />3". OR PER MANUF. <br />BLOCKING <br />SINGLE -PLY ROOF MEMBRANE, WELD <br />TO CLAD -METAL GRAVEL STOP <br />HEAT WELD <br />F-- %Z' COVER BOARD <br />POOL ROOF, TYP <br />SCALE:NTS <br />24 GA. PRE -FINISHED SM COPING <br />SINGLE -PLY ROOF MEMBRANE, INSTALL <br />CONTINUOUSLY o/ WALL <br />HEAT WELD — <br />SELF -ADHERED VAPOR BARRIER <br />CLOSED -CELL SPRAY FOAM (AIR SEAL) <br />V-71 Y6" <br />CLADDING, AS SCHEDULED <br />ROOF TO WALL, TYP. <br />SCALE:NTS <br />GRAVELSTOP <br />FASCIA METAL, PER ARCH. <br />SAM o/ FACE OF FRAMING, EXTEND <br />ONTO SOFFIT 4" MIN. <br />C!o <br />SELF -ADHERED VAPOR BARRIER, EXTEND <br />ONTO CONC. DECK 4" MIN. <br />V <br />CLADDING, AS SCHEDULED <br />FIELD FA WRB, TYP. <br />FA PF LAP o/ VERT. LEG OF FLASHING, TYP. <br />24 GA. PRE -FINISHED SM REGLET FLASHING <br />RECEIVER <br />24 GA. PRE -FINISHED SM COUNTER -FLASHING w/ <br />HEMMED DRIP <br />HEAT WELD, TYP. <br />SINGLE -PLY MEMBRANE, AS SCHEDULED <br />< d, ° e <br />a <br />° °. , d .a.. .. a , . <br />° <br />dd a <br />d < d <br />HTSAM, LAP o/ CLEAT. VERIFY <br />COMPATIBILITY TO SINGLE -PLY ROOF <br />MEMBRANE <br />ROOF OVERFRAMING AND CURB <br />SCALE:NTS <br />CONT. CLEAT <br />CLOSED -CELL SPRAY <br />FOAM (AIR SEAL) <br />STRUCTURE, PER ARCH <br />CLAD SCUPPER <br />MOISTURE -RESISTANT ASSEMBLY <br />INSULATION, AS FOIL -FACED SAM, LAP o/ <br />SCHEDULED FLASHING <br />FOIL -FACED SAM AROUND GUTTER, PER ARCH. <br />PERIMETER OF EXTERIOR <br />WALL <br />24 GA. PRE -FINISHED SM <br />FLASHING w/ HEMMED DRIP <br />FASCIA, PER ARCH. <br />z <br />i0 <br />SOFFIT ASSEMBLY. PER ARCH. <br />ALUM. TERMINATION BAR AND <br />SEALANT. TYP. <br />CLOSED -CELL SPRAY <br />FOAM (AIR SEAL) <br />CLOSED -CELL SPRAY <br />FOAM (AIR SEAL) <br />— 24 GA. PRE -FINISHED SM COPING <br />HTSAM o/ T.O. WALL <br />ALUM. TERMINATION BAR AND <br />SEALANT <br />CUT EDGE SEALANT <br />SELF -ADHERED VAPOR BARRIER <br />(OVER METAL STRUCTURE ONLY) <br />If F SINGLE -PLY ROOF MEMBRANE <br />c <br />y� A POLYI OINDSULATION <br />THROUGH -WALL SCUPPER @ LOW -SLOPE ROOF <br />SCALE:NTS <br />z_ <br />STAINLESS STEEL FASTENER <br />w/ EPDM GASKET <br />CLADDING. AS SCHEDULED <br />WRB, LAP o/ AND SEAL TO <br />VERT. LEG OF FLASHING <br />ALUM. TERMINATION BAR AND <br />SEALANT, TYP. <br />2-PIECE, 24 GA. PRE -FINISHED <br />REGLET AND COUNTERFLASHING <br />w/ HEMMED DRIP <br />:IAG\r/11:14 <br />SINGLE -PLY MEMBRANE o/Y" <br />COVERBOARD o/ TAPERED <br />POLYISO INSULATION o/ CONC. <br />DECK <br />%" SEALANT JOINT w/ <br />BACKER ROD, TYP. <br />PARAPET <br />SCALE:NTS <br />ALUM. TERMINATION BAR <br />AND SEALANT, TYP, <br />2-PIECE, 24 GA. <br />PRE -FINISHED REGLET AND <br />COUNTERFLASHING w/ <br />HEMMED DRIP <br />HEAT WELD <br />FOIL -FACED SAM <br />AROUND PERIMETER <br />OF EXTERIOR WALL <br />24 GA. PRE -FINISHED SM COPING <br />HTSAM o/ T.O. PARAPET <br />GALV. CLEAT <br />STONE VENEER, PER <br />ARCH. FULLYADHEREE <br />MOISTURE -RESISTANT <br />BACKER <br />MOISTURE -RESISTANT <br />INSULATION, AS <br />SCHEDULED <br />WRB, LAP o/ AND SEAL <br />TO VERT. LEG OF <br />FLASHING <br />24 GA. PRE -FINISHED S <br />FLASHING w/ HEMMED I <br />PRE -FINISHED CLEAT, <br />BED INT. LEG IN SEALAI <br />SEALANT JOINT w/ <br />BACKER ROD BETWEEI` <br />PENETRATION FLASHIN <br />AND FRAME, TYP. - DO <br />NOT ADHERE TO CAP <br />ALUM. SF ASSEMBLY, P <br />SCHEDULE <br />C .. d <br />..d d. O d d <br />.. d <br />c <br />ROOF TO WALL @ CONC. DECK <br />SCALE:NTS <br />V) <br />M <br />O <br />N <br />ui <br />0') <br />LN <br />Z <br />z <br />� O <br />0 V <br />z <br />U) <br />Z <br />C) <br />w <br />J <br />U' w <br />0 <br />(If (If <br />w w <br />w w <br />• • v <br />0 <br />0 0 0 N <br />• • • r <br />0 <br />m � <br />E <br />0 <br />o <br />�m <br />c r <br />maD <br />o r m <br />Or 0 <br />> M <br />(h M > <br />Q <br />a <br />N <br />LID In m <br />m co 0 <br />a) <br />3 <br />U- — <br />co <o 3 <br />0 <br />O N <br />00 3 <br />N N <br />N a1 <br />N W <br />3 <br />ROOF DETAILS <br />2020-1009 PERMIT SET <br />THE UNDERSIGNED HAS <br />PROVIDED <br />BUILDING ENCLOSURE DOCUMENTS <br />THAT, IN MY PROFESSIONAL <br />JUDGEMENT, ARE APPROPRIATE TO <br />SATISFY THE REQUIREMENTS OF RCW <br />64.55.005 THROUGH 64.55.090. <br />13012 GEE11VSTEGEE® <br />ARAaoTEcEr <br />COPYRIGHT ©2019 OAC SERVICES, INC. <br />THESEDOCUMENTS, THE IDEAS AND DESIGNS INCORPORATED <br />HEREIN AS AN INSTRUMENT OF SERVICE, ARE THE PROPERTY OF <br />OAC SERVICES, INC. AND ARE NOT TO REUSED IN WHOLE OR IN <br />PART WITHOUT WRITTEN AUTHORIZATION OF OAC SERVICES, INC <br />DESIGN <br />JBI <br />DRAWN <br />KRM <br />CHECK <br />XBE6,02 <br />CAC PROJ. No. <br />R12-200117.01 <br />