EXTERIOR DOOR, AS
<br />SCHEDULED
<br />TURN MEMBRANE UP JAMBS -
<br />TYPICAL w/ PRE -MANUFACTURED
<br />BOOTS OR SIM.
<br />PEDESTAL
<br />PAVER 24 GA. PRE -FINISHED SM SILL PAN -
<br />SYSTEM
<br />FLAT CLOSURE PLATE FOR PAVER EXTEND LEG w/ HEMMED DRIP BELOW
<br />EDGE TERMINATION (WELDED AND T.O. PAVER, TYP.
<br />POWDERCOATED AS PART OF THE
<br />RAILING SYSTEM) ALUMINUM THRESHOLD, TYP.
<br />STAINLESS STEEL CLAMPING
<br />RING AND SEALANT
<br />MANUF. TYPICAL BOOT
<br />M
<br />ROOF ASSEMBLY, AS SCHEDULED
<br />FSINGLE -PLY MEMBRANE AS
<br />SCHEDULED
<br />GUARDRAIL/ PAVER EDGE, TYP
<br />SCALE:NTS
<br />PENTHOUSE DOOR THRESHOLD, TYP.
<br />SCALE:NTS
<br />PIPE/TUBE PENETRATION - PREP SUBSTRATE PER
<br />MANUF., AS REQUIRED
<br />CONTINUOUS SEALANT @ GUMLIP
<br />ABOVE CLASP
<br />STAINLESS STEEL CLASP
<br />a
<br />Z PRE -MANUFACTURED BOOT FLASHING
<br />co
<br />HEAT WELD, TYP.
<br />F— VAPOR BARRIER
<br />PIPE PENETRATION, TYP
<br />SCALE:NTS
<br />SINGLE -PLY ROOF MEMBRANE, WELD
<br />TO CLAD -METAL GRAVEL STOP
<br />r— HEAT WELD
<br />SAM o/ FLASHING
<br />24 GA. PRE -FINISHED
<br />SM FLASHING w/
<br />HEMMED DRIP
<br />TRIM, AS SCHEDULED
<br />LASHING TAP o/ HEAD
<br />FLANGE
<br />BED HEAD FLANGE IN
<br />CONT. SEALANT
<br />HIGH EAVE @ LOUNGE
<br />SCALE:NTS
<br />3". OR PER MANUF.
<br />BLOCKING
<br />SINGLE -PLY ROOF MEMBRANE, WELD
<br />TO CLAD -METAL GRAVEL STOP
<br />HEAT WELD
<br />F-- %Z' COVER BOARD
<br />POOL ROOF, TYP
<br />SCALE:NTS
<br />24 GA. PRE -FINISHED SM COPING
<br />SINGLE -PLY ROOF MEMBRANE, INSTALL
<br />CONTINUOUSLY o/ WALL
<br />HEAT WELD —
<br />SELF -ADHERED VAPOR BARRIER
<br />CLOSED -CELL SPRAY FOAM (AIR SEAL)
<br />V-71 Y6"
<br />CLADDING, AS SCHEDULED
<br />ROOF TO WALL, TYP.
<br />SCALE:NTS
<br />GRAVELSTOP
<br />FASCIA METAL, PER ARCH.
<br />SAM o/ FACE OF FRAMING, EXTEND
<br />ONTO SOFFIT 4" MIN.
<br />C!o
<br />SELF -ADHERED VAPOR BARRIER, EXTEND
<br />ONTO CONC. DECK 4" MIN.
<br />V
<br />CLADDING, AS SCHEDULED
<br />FIELD FA WRB, TYP.
<br />FA PF LAP o/ VERT. LEG OF FLASHING, TYP.
<br />24 GA. PRE -FINISHED SM REGLET FLASHING
<br />RECEIVER
<br />24 GA. PRE -FINISHED SM COUNTER -FLASHING w/
<br />HEMMED DRIP
<br />HEAT WELD, TYP.
<br />SINGLE -PLY MEMBRANE, AS SCHEDULED
<br />< d, ° e
<br />a
<br />° °. , d .a.. .. a , .
<br />°
<br />dd a
<br />d < d
<br />HTSAM, LAP o/ CLEAT. VERIFY
<br />COMPATIBILITY TO SINGLE -PLY ROOF
<br />MEMBRANE
<br />ROOF OVERFRAMING AND CURB
<br />SCALE:NTS
<br />CONT. CLEAT
<br />CLOSED -CELL SPRAY
<br />FOAM (AIR SEAL)
<br />STRUCTURE, PER ARCH
<br />CLAD SCUPPER
<br />MOISTURE -RESISTANT ASSEMBLY
<br />INSULATION, AS FOIL -FACED SAM, LAP o/
<br />SCHEDULED FLASHING
<br />FOIL -FACED SAM AROUND GUTTER, PER ARCH.
<br />PERIMETER OF EXTERIOR
<br />WALL
<br />24 GA. PRE -FINISHED SM
<br />FLASHING w/ HEMMED DRIP
<br />FASCIA, PER ARCH.
<br />z
<br />i0
<br />SOFFIT ASSEMBLY. PER ARCH.
<br />ALUM. TERMINATION BAR AND
<br />SEALANT. TYP.
<br />CLOSED -CELL SPRAY
<br />FOAM (AIR SEAL)
<br />CLOSED -CELL SPRAY
<br />FOAM (AIR SEAL)
<br />— 24 GA. PRE -FINISHED SM COPING
<br />HTSAM o/ T.O. WALL
<br />ALUM. TERMINATION BAR AND
<br />SEALANT
<br />CUT EDGE SEALANT
<br />SELF -ADHERED VAPOR BARRIER
<br />(OVER METAL STRUCTURE ONLY)
<br />If F SINGLE -PLY ROOF MEMBRANE
<br />c
<br />y� A POLYI OINDSULATION
<br />THROUGH -WALL SCUPPER @ LOW -SLOPE ROOF
<br />SCALE:NTS
<br />z_
<br />STAINLESS STEEL FASTENER
<br />w/ EPDM GASKET
<br />CLADDING. AS SCHEDULED
<br />WRB, LAP o/ AND SEAL TO
<br />VERT. LEG OF FLASHING
<br />ALUM. TERMINATION BAR AND
<br />SEALANT, TYP.
<br />2-PIECE, 24 GA. PRE -FINISHED
<br />REGLET AND COUNTERFLASHING
<br />w/ HEMMED DRIP
<br />:IAG\r/11:14
<br />SINGLE -PLY MEMBRANE o/Y"
<br />COVERBOARD o/ TAPERED
<br />POLYISO INSULATION o/ CONC.
<br />DECK
<br />%" SEALANT JOINT w/
<br />BACKER ROD, TYP.
<br />PARAPET
<br />SCALE:NTS
<br />ALUM. TERMINATION BAR
<br />AND SEALANT, TYP,
<br />2-PIECE, 24 GA.
<br />PRE -FINISHED REGLET AND
<br />COUNTERFLASHING w/
<br />HEMMED DRIP
<br />HEAT WELD
<br />FOIL -FACED SAM
<br />AROUND PERIMETER
<br />OF EXTERIOR WALL
<br />24 GA. PRE -FINISHED SM COPING
<br />HTSAM o/ T.O. PARAPET
<br />GALV. CLEAT
<br />STONE VENEER, PER
<br />ARCH. FULLYADHEREE
<br />MOISTURE -RESISTANT
<br />BACKER
<br />MOISTURE -RESISTANT
<br />INSULATION, AS
<br />SCHEDULED
<br />WRB, LAP o/ AND SEAL
<br />TO VERT. LEG OF
<br />FLASHING
<br />24 GA. PRE -FINISHED S
<br />FLASHING w/ HEMMED I
<br />PRE -FINISHED CLEAT,
<br />BED INT. LEG IN SEALAI
<br />SEALANT JOINT w/
<br />BACKER ROD BETWEEI`
<br />PENETRATION FLASHIN
<br />AND FRAME, TYP. - DO
<br />NOT ADHERE TO CAP
<br />ALUM. SF ASSEMBLY, P
<br />SCHEDULE
<br />C .. d
<br />..d d. O d d
<br />.. d
<br />c
<br />ROOF TO WALL @ CONC. DECK
<br />SCALE:NTS
<br />V)
<br />M
<br />O
<br />N
<br />ui
<br />0')
<br />LN
<br />Z
<br />z
<br />� O
<br />0 V
<br />z
<br />U)
<br />Z
<br />C)
<br />w
<br />J
<br />U' w
<br />0
<br />(If (If
<br />w w
<br />w w
<br />• • v
<br />0
<br />0 0 0 N
<br />• • • r
<br />0
<br />m �
<br />E
<br />0
<br />o
<br />�m
<br />c r
<br />maD
<br />o r m
<br />Or 0
<br />> M
<br />(h M >
<br />Q
<br />a
<br />N
<br />LID In m
<br />m co 0
<br />a)
<br />3
<br />U- —
<br />co <o 3
<br />0
<br />O N
<br />00 3
<br />N N
<br />N a1
<br />N W
<br />3
<br />ROOF DETAILS
<br />2020-1009 PERMIT SET
<br />THE UNDERSIGNED HAS
<br />PROVIDED
<br />BUILDING ENCLOSURE DOCUMENTS
<br />THAT, IN MY PROFESSIONAL
<br />JUDGEMENT, ARE APPROPRIATE TO
<br />SATISFY THE REQUIREMENTS OF RCW
<br />64.55.005 THROUGH 64.55.090.
<br />13012 GEE11VSTEGEE®
<br />ARAaoTEcEr
<br />COPYRIGHT ©2019 OAC SERVICES, INC.
<br />THESEDOCUMENTS, THE IDEAS AND DESIGNS INCORPORATED
<br />HEREIN AS AN INSTRUMENT OF SERVICE, ARE THE PROPERTY OF
<br />OAC SERVICES, INC. AND ARE NOT TO REUSED IN WHOLE OR IN
<br />PART WITHOUT WRITTEN AUTHORIZATION OF OAC SERVICES, INC
<br />DESIGN
<br />JBI
<br />DRAWN
<br />KRM
<br />CHECK
<br />XBE6,02
<br />CAC PROJ. No.
<br />R12-200117.01
<br />
|