Laserfiche WebLink
DIMENSIONAL LUMBER <br />FIRE RETARDANT TREATED LUMBER <br />SHRINKAGE SETTLEMENT <br />SHOP DRAWINGS AND SUBMITTALS <br />U) <br />w <br />O <br />z <br />J <br />9 <br />w <br />z <br />w <br />0 <br />r <br />r <br />U) <br />00 <br />C� <br />J <br />m <br />U) <br />ly- <br />z <br />0Y <br />O <br />U <br />tY <br />O <br />LL <br />LLi <br />a <br />z <br />w <br />J_ <br />LL <br />1. MEET THE REQUIREMENTS OF PS 20-70 AND NATIONAL GRADING RULES FOR <br />SOFTWOOD DIMENSIONAL LUMBER. ALL MEMBERS ARE TO BEAR THE STAMP OF THE <br />WWPA. MOISTURE CONTENT AT THE TIME OF FRAMING IS TO BE 19% OR LESS. <br />2. MINIMUM DIMENSIONAL LUMBER GRADES ARE TO BE: <br />WALL STUDS 2x DF STUD GRADE <br />WALL PLATES 2x DF STANDARD GRADE <br />2x PT DF STANDARD GRADE <br />PER PLAN AT CONCRETE <br />JOISTS 2x DF #2 <br />HEADERS/BEAMS 4x, 6x DF #2 <br />POSTS 4x, 6x DF #2 <br />3. ALL WOOD IN CONTACT WITH CONCRETE SHALL BE PRESSURE TREATED LUMBER. <br />NAILS AND PLATE WASHERS IN CONTACT WITH TREATED LUMBER SHALL BE <br />HOT -DIPPED GALVANIZED. ANCHOR BOLTS AND LAG SCREWS IN TREATED LUMBER SHALL <br />BE HDG OR ZINC COATED. PLAIN CARBON STEEL FASTENERS MAY BE USED WITH <br />ZINC -BORATE TREATED LUMBER. <br />4. FOUNDATION SILL PLATES ARE TO BE BOLTED TO THE CONCRETE FOUNDATION WITH <br />%" O ANCHOR BOLTS EMBED A MINIMUM 7" OR 4" O MECHANICAL ANCHORS EMBED AS <br />SPECIFIED ON DRAWINGS. PROVIDE A MINIMUM OF TWO BOLTS PER PLATE SECTION A <br />MAXIMUM OF 9" FROM THE PLATE END. MAXIMUM SPACING OF ANCHORS IS TO BE <br />4'-0". PROVIDE 0.229"x3" SQ. WASHERS AT ALL ANCHOR BOLTS. WASHER EDGES <br />MUST BE WITHIN %" OF WALL SHEATHING. <br />5. SHOT PIN ATTACHMENTS FOR SILL PLATES ARE TO BE SIMPSON FASTENERS OR <br />APPROVED ALTERNATE. SHOT PIN SIZES ARE AS FOLLOWS: <br />PLATE <br />EMBED <br />THICKNESS <br />MATERIAL <br />SHOT PIN <br />2x <br />CONC <br />PDPWL-250MG <br />2x <br />STEEL <br />PDPA-200 <br />6. BOLTS IN WOOD BEAMS SHALL NOT BE LESS THAN 7 DIAMETERS FROM THE END AND <br />4 DIAMETERS FROM THE MEMBER EDGE. PROVIDE STANDARD WASHERS FOR ALL NUTS <br />BEARING AGAINST WOOD. <br />7. FASTEN ALL MEMBERS IN ACCORDANCE WITH IBC TABLE 2304.10.1, UNLESS NOTED <br />OTHERWISE. PROVIDE MINIMUM 1Y" EMBED FOR ALL NAILS. NAIL SIZES ARE AS <br />FOLLOWS: <br />NAIL <br />MIN. SHANK DIA. <br />8d <br />0.131" <br />10d <br />0.148" <br />16d <br />0.162" <br />8. HOLES AND NOTCHES IN WOOD MEMBERS ARE TO BE LIMITED AS SUCH: <br />L/3 <br />NO HOLES IN THIS AR <br />Q <br />SA0 <br />N � Q <br />NO LIMIT <br />JOIST <br />BEAM <br />MAX. HOLE DIA. <br />40% STUD DEPTH <br />1%" FOR 2x4 NO MORE THAN <br />2%" FOR 2x6 Y I TWO SUCCESSIVE <br />TOE DOUBLED STUDS <br />ARE ALLOWED <br />MAX. NOTCH <br />25% STUD DEP <br />%" FOR 2x4 <br />1%" FOR 2x6 <br />HOLES ARE NOT <br />PERMITTED IN <br />SAME SECTION <br />AS NOTCH <br />STUDS <br />GLU-LAMINATED MEMBERS <br />DBL <br />STUD FOR HOLE <br />DIA. <br />OF UP TO 60% <br />STUD DEPTH <br />2%" <br />FOR 2x4 <br />3%" <br />FOR 2x6 <br />1. SINGLE -SPAN GLU-LAMINATED WOOD MEMBERS ARE TO BE DOUGLAS FIR, KILN DRIED <br />AND AITC SPECIFICATION 24F-V4, UNLESS NOTED OTHERWISE. MULTI -SPAN OR <br />CANTILEVERED GLU-LAMINATED WOOD MEMBERS TO BE AITC SPECIFICATION 24F-V8, <br />UNLESS OTHERWISE NOTED. BEAMS ARE HAVE A 2,000 FT RADIUS CAMBER, UNLESS <br />NOTED OTHERWISE. <br />2. MATERIALS MUST BE OBTAINED FROM AN AITC APPROVED FABRICATOR AND BEAR <br />THE AITC STAMP. <br />3. THE GLUE IS TO BE A "WET -USE" ADHESIVE. <br />1. FRT LUMBER IS TO BE DRICON FRT WOOD APPLIED TO DOUGLAS FIR LUMBER AND <br />APA EXP-1 RATED PLYWOOD. ALTERNATE TREATMENTS REQUIRE ENGINEER APPROVAL. <br />2. PLAIN CARBON STEEL FASTENERS ARE ACCEPTABLE TO USE WITH DRICON FRT WOOD. <br />SILL PLATES IN CONTACT WITH CONCRETE MUST BE BOTH PRESSURE TREATED AND <br />FRT AND REQUIRE FASTENERS TO BE HDG AS NOTED ELSEWHERE. <br />3. THE STRENGTH DESIGN FACTOR FOR DRICON FRT WOOD IS AS NOTED BELOW AND HAS <br />BEEN ACCOUNTED FOR IN THE DESIGN: <br />STRENGTH DESIGN <br />DESIGN FACTOR <br />COMPRESSION <br />0.91 <br />HORIZ. SHEAR <br />0.94 <br />BENDING, Fb <br />0.90 <br />BENDING, E <br />0.98 <br />WOOD STRUCTURAL CONNECTIONS <br />1. ALL FRAMING ANCHORS, POST CAPS, BASES, HANGERS STRAPS, ETC. SHALL BE AS <br />MANUFACTURED BY SIMPSON STRONG -TIE OR ENGINEER APPROVED EQUAL. <br />WOOD TRUSSES <br />1. SUBMIT SHOP DRAWINGS AND CALCULATIONS STAMPED, SIGNED AND DATED BY A <br />LICENSED ENGINEER IN THE STATE OF THE PROJECT TO THE ENGINEER OF RECORD <br />FOR REVIEW. <br />2. TRUSS PLATES ARE TO BE ICBO APPROVED. TOP CHORDS ARE TO BE DOUGLAS FIR <br />#2 OR BETTER. <br />3. INSTALL BRIDGING, WEB AND CHORD BRACING AS REQUIRED BY THE TRUSS <br />FABRICATOR. <br />4. TEMPORARY SHORING AND BRACING OF THE TRUSSES DURING ERECTION IS THE <br />RESPONSIBILITY OF THE CONTRACTOR. <br />MANUFACTURED LUMBER <br />1. PARALLEL STRAND LUMBER (PSL) IS TO BE 2.0E PARALLAM MANUFACTURED BY <br />TRUSJOIST BY WEYERHAUESER OR ENGINEER APPROVED EQUAL. <br />2. LAMINATED VENEER LUMBER (LVL) IS TO BE 2.0E MICROLLAM MANUFACTURED BY <br />TRUSJOIST BY WEYERHAUESER OR ENGINEER APPROVED EQUAL. <br />3. LAMINATED STRAND LUMBER (LSL) IS TO BE: <br />• 1%" WIDE LSL 1.3E OR BETTER <br />0 3%" WIDE LSL 1.55E OR BETTER <br />MANUFACTURED BY TRUSJOIST BY WEYERHAUESER OR ENGINEER APPROVED EQUAL. <br />4. MANUFACTURED I -JOISTS ARE TO BE TJI SERIES MEMBERS AND SPECIFIED IN THE <br />DRAWINGS MANUFACTURED BY TRUSJOIST BY WEYERHAUESER OR ENGINEER <br />APPROVED EQUAL. <br />WOOD SHEATHING <br />1. ROOF SHEATHING. MINIMUM THICKNESS PER PLAN. APA RATED, EXP-1 RATING, <br />EDGE SEALED PANELS CONFORMING TO INDENTIFICATION INDEX 32/16 FOR SLOPES <br />GREATER THAN 3/12 AND 40/20 FOR SLOPES 3/12 AND LESS. PROVIDE MINIMUM <br />1/8" CLEAR BETWEEN PANELS TO ALLOW FOR EXPANSION. NAIL 6 INCHES ON <br />CENTER ALONG EDGES AND 12 INCHES ON CENTER AT INTERMEDIATE SUPPORTS, <br />UNLESS NOTED OTHERWISE. USE 10d COMMON NAILS. <br />2. FLOOR SHEATHING. MINIMUM THICKNESS PER PLAN. APA RATED STURD-I-FLOOR, <br />EXP-1 RATING, TONGUE AND GROOVE EDGES CONFORMING TO IDENTIFICATION <br />INDEX 48/24. PROVIDE MINIMUM 1/8" CLEAR BETWEEN PANELS TO ALLOW FOR <br />EXPANSION. NAIL AND GLUE TO SUPPORTS. GLUE ADHESIVE IS TO CONFORM TO <br />APA SPECIFICATION AFG-01. NAIL 6 INCHES ON CENTER ALONG EDGES AND 12 <br />INCHES ON CENTER AT INTERMEDIATE SUPPORTS, UNLESS NOTED OTHERWISE. USE <br />10d COMMON NAILS. <br />PANEL EDGE NAILING <br />AT DIAPHRAGM <br />PERIMETER <br />STAGGER PANEL <br />JOINTS, TYP. <br />- 1 <br />LAYOUT PANELS <br />PERPENDICULAR <br />TO FRAMING, TYP. <br />EDGE NAILING <br />AT ALL- SUPPORTED° <br />PANEL EDGES <br />FIELD NAILING <br />PANEL EDGE <br />AT INTERMEDIATE <br />NAILING AT <br />SUPPORTS, TYP <br />""'" ALL PANEL <br />EDGES <br />BLOCKED <br />DIAPHRAGM <br />IF NOTED <br />PER PLAN <br />UNBLOCKED <br />DIAPHRAGM <br />DIA <br />DIA <br />FLAT 2x4 BLKG AT <br />U.N.O. <br />ALL UNSUPPORTED <br />PANEL EDGES <br />ROOF/FLOOR <br />DIAPHRAGM NAILING <br />3. WOOD SHEARWALL SHEATHING. MINIMUM THICKNESS PER PLAN. PLYWOOD OR OSB <br />APA RATED, EXP-1 RATING. NAILING PER DRAWINGS. <br />1. DUE TO CROSS GRAIN WOOD SHRINKAGE, THIS BUILDING IS EXPECTED TO SETTLE <br />APPROXIMATELY %" PER WOOD FRAMED STORY. THIS SHRINKAGE WILL OCCUR WITHIN <br />THE WALL PLATES AND NOT ALONG THE LENGTH OF THE STUDS. <br />2. ALL PLUMBING AND MECHANICAL DUCTS SHALL BE DESIGNED WITH FLEXIBLE JOINTS <br />OR OTHER MEANS TO ACCOMMODATE THIS NORMAL SETTLEMENT. <br />STRUCTURAL OBSERVATION <br />STRUCTURAL OBSERVATIONS BY THE ENGINEER OF RECORD ARE REQUIRED FOR THIS <br />PROJECT. OBSERVATIONS ARE TO OCCUR: <br />1. PRIOR TO EACH ELEVATED CONCRETE SLAB POUR. <br />2. BETWEEN THE FRAMING OF THE SECOND AND THIRD FLOORS. <br />3. AFTER ROOF SHEATHING IS IN PLACE, PRIOR TO DRYWALL INSTALLATION. <br />THE OWNER SHALL EMPLOY A REGISTERED DESIGN PROFESSIONAL TO PERFORM <br />STRUCTURAL OBSERVATIONS. DEFICIENCIES SHALL BE REPORTED IN WRITING TO THE OWNER <br />AND THE BUILDING OFFICIAL. AT THE CONCLUSION OF THE WORK INCLUDED IN THE PERMIT, <br />THE STRUCTURAL OBSERVER SHALL SUBMIT TO THE BUILDING OFFICIAL A WRITTEN <br />STATEMENT THAT THE SITE VISITS HAVE BEEN MADE AND IDENTIFY ANY REPORTED <br />DEFICIENCIES WHICH, TO THE BEST OF THE STRUCTURAL OBSERVER'S KNOWLEDGE, HAVE <br />NOT BEEN RESOLVED. <br />JOB SITE SAFETY <br />THE ENGINEER HAS NOT BEEN RETAINED OR COMPENSATED TO PROVIDE DESIGN AND/OR <br />CONSTRUCTION REVIEW SERVICES RELATED TO THE CONTRACTOR'S SAFETY PRECAUTIONS OR <br />TO MEANS, METHODS, TECHNIQUES OR PROCEDURES FOR THE CONTRACTOR TO PERFORM <br />THE WORK. THE UNDERTAKING OF PERIODIC SITE VISITS BY THE ENGINEER SHALL NOT BE <br />CONSTRUED AS SUPERVISION OF ACTUAL CONSTRUCTION NOR MAKE HIM RESPONSIBLE FOR <br />PROVIDING A SAFE PLACE FOR THE PERFORMANCE OF THE WORK BY THE CONTRACTOR, <br />SUB -CONTRACTOR OR ANY PERSON ON THE SITE. <br />1. SUBMIT LAYOUT DRAWINGS IN PDF FORMAT FOR REVIEW OF: <br />A. REINFORCING STEEL <br />B. STRUCTURAL STEEL <br />C. POST -TENSIONED TENDONS <br />D. PRE -MANUFACTURED ENGINEERED WOOD TRUSSES <br />E. SPRINKLER SYSTEM <br />F. ELEVATOR <br />2. SUBMIT SPECIFICATIONS IN PDF FORMAT FOR REVIEW OF: <br />A. CONCRETE DESIGN MIX <br />B. CONCRETE INSERTS <br />DEFERRED SUBMITTALS <br />1. PLANS FOR DEFERRED SUBMITTAL ITEMS SHALL BE SUBMITTED IN A TIMELY MANNER <br />THAT ALLOWS A MINIMUM OF 10 WORKING DAYS FOR THE ENGINEER PLUS AN <br />ADDITIONAL 30 WORKING DAYS FOR INITIAL PLAN REVIEW FROM THE CITY. ALL <br />COMMENTS RELATED TO THE DEFERRED SUBMITTAL MUST BE ADDRESSED TO THE <br />SATISFACTION OF THE PLAN CHECK DIVISION PRIOR TO APPROVAL OF THE SUBMITTED <br />I TEMS. <br />2. THE DEFERRED SUBMITTAL ITEMS INCLUDE THE FOLLOWING: <br />A. PRE -MANUFACTURED ENGINEERED WOOD TRUSSES <br />B. FIRE SPRINKLER DRAWINGS <br />SPECIAL INSPECTIONS <br />1. SPECIAL INSPECTIONS ARE TO BE PERFORMED BY INDEPENDENT, JURISDICTIONALLY <br />APPROVED AGENCY IN ACCORDANCE WITH SBC SECTION 1703 AND PROVIDE THE <br />DUTIES AND RESPONSIBILITIES AS INDICATED IN SECTION 1704. <br />2. A CERTIFICATE OF SATISFACTORY COMPLETION OF WORK REQUIRING SPECIAL <br />INSPECTION MUST BE COMPLETED AND SUBMITTED TO THE BUILDING OFFICIAL UPON <br />COMPLETION OF PROJECT. <br />3. SPECIAL INSPECTION IS NOT A SUBSTITUTE FOR INSPECTION BY A JURISDICTIONAL <br />INSPECTOR. <br />4. THE SPECIAL INSPECTIONS REQUIRED FOR THIS PROJECT ARE AS FOLLOWS: <br />SUMMARY OF SPECIAL INSPECTION <br />ITEM <br />INSPECTION REQUIRED <br />REMARK <br />GRADING AND EXCAVATION <br />VERIFY MATERIAL BELOW FOOTING FOR DESIGN BEARING CAPACITY, PERIODIC INSPECTION <br />REFER TO GEOTECHNICAL REPORT <br />VERIFY EXCAVATION TO PROPER DEPTH; PERIODIC INSPECTION <br />VERIFY USE OF PROPER MATERIALS, DENSITIES AND LIFT THICKNESS DURING PLACEMENT AND <br />COMPACTION OF FILL; CONTINUOUS INSPECTION <br />CONCRETE <br />VERIFY MIX DESIGN SUPPLIED MEETS APPROVED MIX DESIGN; PERIODIC INSPECTION <br />REFER TO STAMPED MIX DESIGN BY DCG <br />PLACEMENT OF CONCRETE, INCLUDES VERIFYING SLUMP AND AIR CONTENT TESTS; CONTINUOUS <br />INSPECTION <br />REFER TO DRAWINGS; NOT REQUIRED FOR <br />SITE -WORK CONCRETE <br />VERIFY ANCHOR BOLTS ARE PLACED AND TIED PROPERLY, CONTINUOUS INSPECTION <br />REFER TO DRAWINGS <br />PERFORM CYLINDER STRENGTH TESTS <br />FOOTINGS/SLAB-ON-GRADE - 3,000 PSI <br />COLUMNS - 4,000 PSI <br />WALLS - 4, 000 PSI <br />ELEVATED SLABS - 6,000 PSI <br />SHOTCRETE <br />PERFORM CYLINDER STRENGTH TESTS <br />WALLS - 4000 PSI <br />VERIFY MIX DESIGN SUPPLIED MEETS APPROVED MIX DESIGN; PERIODIC INSPECTION <br />REFER TO STAMPED MIX DESIGN BY DCG <br />PLACEMENT OF SHOTCRETE, INCLUDES VERIFYING SLUMP AND AIR CONTENT TESTS; CONTINUOUS <br />INSPECTION <br />REFER TO DRAWINGS <br />PROVIDE 46' TEST PANELS MATCHING REINFORCING ON DRAWINGS. 3 CORE SAMPLES FROM <br />EACH PANEL ARE TO BE TAKEN TO VERIFY PROPER PLACEMENT. NOZZLEMAN, MIX AND <br />EQUIPMENT ARE TO BE THE SAME AS USED ON THE PROJECT. CONTINUOUS INSPECTION OF <br />PLACEMENT. <br />PANEL TO BE REPRESENTATIVE OF THE MOST CONGESTED REINFORCING. <br />ONE PANEL REQUIRED PER BUILDING. <br />REINFORCING STEEL <br />VERIFY PLACEMENT, COVER AND BAR SIZE; PERIODIC INSPECTION <br />REFER TO DRAWINGS <br />VERIFY GRADE; PERIODIC INSPECTION <br />ASTM A615, GRADE 60 <br />STRUCTURAL STEEL <br />VERIFY MEMBER SIZES AND PLACEMENT, AND BOLTED CONNECTIONS ARE SNUG -TIGHT, PERIODIC <br />INSPECTION <br />REFER TO DRAWINGS <br />ON -SITE WELDING <br />PERIODIC INSPECTION OF FILLET WELDS %6" AND LESS <br />POST -TENSIONED TENDONS <br />VERIFY HEIGHTS AND PLACEMENT PRIOR TO POURING; PERIODIC INSPECTION <br />REFER TO DRAWINGS <br />TENDON STRESSING; CONTINUOUS INSPECTION <br />SUBMIT STRESSING REPORT TO ENGINEER OF RECORD FOR REVIEW <br />EPDXY OR MECHANICAL ANCHORS <br />VERIFY INSTALLATION SIZE AND DEPTH; CONTINUOUS INSPECTION <br />REFER TO DRAWINGS OR FIELD DIRECTIVES <br />WOOD FLOOR/WALL DIAPHRAGMS <br />VERIFY NAIL SIZE, SPACING, SHEATHING TYPE, BLOCKING, ETC.; PERIODIC INSPECTION <br />REFER TO DRAWINGS <br />9706 4th Avenue NE <br />Suite 300 <br />Seattle, WA 98115 <br />P: 206.523.0024 <br />F: 206.523.1012 <br />www.dogengr.com <br />C- SC <br />S11 �cF WAS&�/ <br />�P �0� <br />p 37334 t� <br />GCTURAL EN�N <br />STAMP <br />Z <br />O <br />a <br />as - <br />w <br />�E <br />W <br />�� <br />z <br />o <br />m� <br />Q <br />N <br />� <br />o <br />U) <br />W <br />FLU <br />o <br />a <br />z <br />U) <br />c <br />4. <br />c <br />d <br />�a <br />c <br />d <br />�11 <br />U <br />W <br />o' <br />a <br />W <br />�- <br />F <br />O <br />z <br />a <br />Z <br />0 <br />W <br />o <br />'w <br />V/ <br />LL <br />Ed <br />*+ <br />W <br />0 <br />= <br />Z <br />z <br />W <br />Z <br />0 <br />42 Z <br />�LU <br />Va <br />W <br />Q� <br />EU <br />oZ <br />CL <br />UQ <br />� <br />LL <br />Q <br />3. M <br />o <br />Q <br />y <br />Go <br />a <br />m <br />WZ <br />F- <br />L <br />�� <br />0Z <br />°o <br />, <br />AW <br />> <br />o <br />o <br />o� <br />w <br />N <br />w® <br />CD <br />a� <br />L <br />co w <br />z <br />W.� <br />0 <br />UJ�00 <br />v <br />00 <br />we <br />w <br />a 11-- Q <br />�, `° <br />�W <br />Z <br />L <br />a <br />Q <br />wUZ <br />Z <br />w <br />z o <br />3- <br />LL <br />co <br />o li Ella)F <br />a <br />PROJECT #: 1827 <br />DRAWN BY: TF/BV/JH <br />CHECKED BY: MS/EM <br />GENERAL <br />NOTES <br />Simi <br />