Laserfiche WebLink
ENERGY CODE COMPLIANCE <br />ALLOWABLE BUILDING HEIGHT AND AREA <br />L: <br />X <br />U <br />co <br />I <br />Z <br />I <br />U <br />U <br />U) <br />I <br />L <br />a) <br />L <br />O <br />U <br />L <br />O <br />LL <br />I` <br />N <br />00 <br />U <br />U <br />U <br />O <br />0 <br />X <br />U <br />g <br />L <br />A <br />5 STORY APARTMENT BUILDING <br />OVER PARKING STRUCTURE <br />CODE INFORMATION AND NOTES <br />GOVERNING CODES <br />CITY OF EVERETT, WASHINGTON STATE <br />2015 INTERNATIONAL BUILDING CODE (IBC) <br />2015 INTERNATIONAL MECHANICAL CODE (IMC) <br />2015 INTERNATIONAL FUEL GAS CODE (IFGC) <br />2015 INTERNATIONAL FIRE CODE (IFC) <br />2015 WASHINGTON STATE ENERGY CODE COMMERCIAL (WSEC) <br />2015 WASHINGTON STATE ENERGY CODE APPENDIX (WSEC) <br />2015 UNIFORM PLUMBING CODE (UPC) <br />2015 NATIONAL FUEL GAS CODE (NFPA 54) <br />2014 NATIONAL ELECTRICAL CODE (NFPA 70) <br />2015 WASHINGTON STATE-WIDE AMENDMENTS <br />ICC A117.1-2009 ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES <br />2010 ADA STANDARDS FOR ACCESSIBLE DESIGN (RECREATION CENTER) <br />ivi III ► I Is] 1 :7_1 S0101 I] d <br />CITY OF EVERETT MUNICIPAL CODE <br />TITLE 19 ZONING CODE <br />CHAPTER 19 31 BE E-1 / MUO ZONES <br />OCCUPANCY GROUPS <br />(PER IBC 508.3): <br />R-2: RESIDENTIAL & ASSEMBLY USES < 50 OCCUPANTS <br />S-2: ENCLOSED PARKING GARAGE & LOW HAZARD STORAGE <br />B OFFICES & BUSINESS, MAINTENANCE & FITNESS CENTERS <br />A-3 LOUNGE AND RELATED AREAS, GAME ROOM AND CONVENING SPACES, <br />BASKETBALL COURT <br />A-4 POOL, SPA, AND POOL DECK AREAS <br />CONSTRUCTION TYPES / CODE NOTES <br />LEVELS: <br />LEVELS 2-6 <br />LEVEL 1 <br />OCCUPANCY GROUPS: <br />R-2 <br />S-2 <br />CONSTRUCTION TYPE: <br />TYPE V-A <br />TYPE 1-A <br />1. BUILDING PROTECTED THROUGHOUT BY AN APPROVED AUTOMATIC SPRINKLER <br />SYSTEM IN ACCORDANCE WITH 903.3.1.1 (NFPA 13): THE ENTIRE SPRINKLER SYSTEM <br />INCLUDING THE UNDERGROUND SUPPLY LINE SHALL BE INSTALLED BY A STATE <br />LICENSED SPRINKLER CONTRACTOR WITH THE APPROPRIATE LEVEL OF <br />CERTIFICATION. SEPARATE PERMIT REQUIRED FOR ALL SPRINKLER WORK INCLUDING <br />UNDERGROUND. <br />2. STAIR ENCLOSURE PRESSURIZATION INCREASE: 5 STORY / V-A ALLOWANCE. <br />INTERIOR EXIT STAIRWAYS ARE PRESSURIZED IN ACCORDANCE WITH SECTION 909. <br />LEGALLY REQUIRED STANDBY POWER SHALL BE PROVIDED AND CONNECTED TO <br />STAIRWAY SHAFT PRESSURIZATION EQUIPMENT, ELEVATORS USED FOR ACCESSIBLE <br />MEANS OF EGRESS, HOISTWAY PRESSURIZATION EQUIPMENT AND OTHER LIFE <br />SAFETY EQUIPMENT. LEGALLY REQUIRED STANDBY POWER SHALL COMPLY WITH 2O14 <br />NEC SECTION 701.12, OPTIONS (A), (B), (C), (D), (F), OR (G). <br />3. LEGALLY REQUIRED STANDBY POWER TO BE PROVIDED VIA A SECONDARY SERVICE <br />IN COMPLIANCE WITH THE CITY OF EVERETT REGULATIONS. SECONDARY SERVICE TO <br />BE UNDER SEPARATE PERMIT. <br />4. FIRE ALARM: A FIRE ALARM SYSTEM SHALL BE INSTALLED THROUGHOUT THE BUILDING <br />PER SNOHOMISH COUNTY FIRE DEPARTMENT OPERATING POLICY AND SHALL COMPLY <br />WITH WASHINGTON STATE BARRIER FREE REQUIREMENTS REGARDING INSTALLATION <br />OF VISUAL DEVICES AND PULL STATIONS. THIS WORK IS UNDER SEPARATE PERMIT. <br />5. CLASS I STANDPIPE IS REQUIRED PER 2015 IBC SECTION 905. <br />6. BUILDING RADIO COVERAGE: THE BUILDING SHALL HAVE APPROVED RADIO COVERAGE <br />FOR EMERGENCY RESPONDERS WITHIN THE BUILDING EITHER BY MINIMUM SIGNAL <br />STRENGTH LEVELS OF THE SNOHOMISH COUNTY REGIONAL 800 MHz RADIO SYSTEM <br />OR BY A SYSTEM INSTALLED WITHIN THE BUILDING IN ACCORDANCE WITH SECTION <br />510 OF THE IFC AND WITH APPLICABLE PROVISIONS OF NFPA 72, NATIONAL FIRE <br />ALARM SIGNALING CODE <br />STAIRWAY PRESSURIZATION <br />STAIRWELLS TO BE PRESSURIZED IN ACCORDANCE WITH WSBC SECTION 909 <br />1. STANDBY POWER <br />2. SPECIAL INSPECTION <br />RATIONAL ANALYSIS PREPARED BY ALLEN ENGINEERING <br />ADDRESSING <br />APPROVED NUMBERS OR ADDRESSES SHALL BE PLACED ON ALL NEW OR <br />EXISTING BUILDINGS IN SUCH A POSITION AS TO BE PLAINLY VISIBLE FROM <br />THE STREET OR ROAD FRONTING THE PROPERTY. FOR MULTIPLE BUILDING <br />COMPLEXES, BUILDING DESIGNATION LETTERS OR NUMBERS MUST BE <br />VISIBLE FROM THE PRIMARY DRIVE PATH IN THE COMPLEX. NUMBERS SHALL <br />CONTRAST WITH THEIR BACKGROUND. SIZING SHALL BE IN ACCORDANCE <br />WITH CITY OF EVERETT REGULATIONS. <br />2015 WASHINGTON STATE ENERGY CODE <br />RESIDENTIAL BUILDING. For this code, includes detached one- and two-family dwellings and <br />multiple single-family dwellings (townhouses) as well as Group R-2, R-3 and R-4 buildings three <br />stories or less in height above grade plane. <br />COMMERCIAL BUILDING. For this code, all buildings that are not included in the definition of <br />"Residential buildings." <br />Therefore the R-2 occupancy, 5-story apartment buildings fall under the scope of the <br />Commercial Energy Code. <br />Chapter 51-11C WAC <br />Table C301.1 Climate Zone: SNOHOMISH COUNTY - 4C <br />SECTION C402.1.3 - SPECIFIC INSULATION REQUIREMENTS (Prescriptive) <br />TABLE C402.1.3 - OPAQUE THERMAL ENVELOPE REQUIREMENTS <br />ROOFS <br />ATTIC SPACES R-49 FULL DEPTH AT ENTIRE ATTIC (RAISED HEEL TRUSSES) <br />ABOVE ROOF DECK R-38 CONTINUOUS INSULATION <br />WALLS, ABOVE GRADE <br />MASS WALLS R-13.3 CONTINOUOUS INSULATION <br />STEEL FRAMED WALLS R-19 + R-8.5 CONTINUOUS INSULATION <br />MASS FLOORS R-30 BATT OR R-30 CONTINUOUS <br />SLAB -ON -GRADE FLOORS <br />UNHEATED FLOORS R-10 FOR 24" BELOW <br />OPAQUE DOORS (DOORS WITH LESS THAN 50% GLAZING AREA) <br />SWINGING U-0.37 <br />TABLE C402.4 - BUILDING ENVELOPE REQUIREMENTS - FENESTRATION <br />VERTICAL FENESTRATION <br />NONMETAL FRAMING (ALL TYPES) U-VALUE 0.30 MAX <br />SHGC PF < 0.2 SEW 0.40 MAX <br />N 0.53 MAX <br />C402.4.1 MAXIMUM AREA <br />VERTICAL FENESTRATION SHALL NOT EXCEED 30% OF THE GROSS ABOVE - <br />GRADE WALL AREA. <br />SEE FENESTRATION CALCULATIONS ON CS SHEETS <br />C402.5 -AIR LEAKAGE (MANDATORY) <br />THE THERMAL ENVELOPE OF BUILDINGS SHALL COMPLY WITH SECTIONS C402.5.1 <br />THROUGH C402.5.8. <br />SUSTAINABLE PROGRAMS <br />1. EVERGREEN SUSTAINABLE DEVELOPMENT v3.0: <br />REFERENCE EVERGREEN PROJECT PLAN AND COMPLIANCE CHECKLIST PREPARED <br />BY OWNER & GENERAL CONTRACTOR. <br />DEFERRED SUBMITTALS <br />SUBMITTAL DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE SUBMITTED TO THE <br />ARCHITECT OR ENGINEER OF RECORD WHO SHALL REVIEW THEM AND STAMP THEM WITH A <br />NOTATION INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE BEEN REVIEWED AND <br />THAT THEY HAVE BEEN FOUND IN GENERAL CONFORMANCE WITH THE DESIGN OF THE BUILDING. <br />DEFERRED SUBMITTALS WILL BE RETURNED TO THE CONTRACTOR, WHO WILL IN TURN SUBMIT <br />THEM TO THE BUILDING DEPARTMENT. <br />THE DEFERRED SUBMITTAL ITEMS SHALL NOT BE INSTALLED UNTIL THEIR DESIGN AND <br />SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING DEPARTMENT. <br />THE FOLLOWING ITEMS ARE DEFERRED SUBMITTALS: <br />1. PRE-ENGINEERED ROOF TRUSS SHOP DRAWINGS <br />2. FIRE STOPPING / FIRE RESISTANCE JOINT SYSTEMS <br />3. MECHANICAL SYSTEMS INCLUDING STAIR PRESSURIZATION (2015 IMC) <br />4. ELECTRICAL SYSTEMS INCLUDING LEGALLY REQUIRED STANDBY POWER (2014 NEC) <br />5. PLUMBING SYSTEMS (2015 UPC, 2015NFGC, 2015 IFGC) <br />THE FOLLOWING BIDDER -DESIGN/ BUILD ITEMS REQUIRE SEPARATE PERMITS: <br />1. FIRE SUPPRESSION SYSTEM (NFPA 13 & SPRINKLER AND STANDPIPES, 2014 ED.) <br />2. FIRE ALARM SYSTEM (NFPA 72) <br />3. SIGNAGE <br />4. OUTDOOR POOL & SPA <br />5. ELEVATOR <br />COORDINATION NOTES <br />THE FOLLOWING NOTES SHALL SERVE AS A GUIDE TO THE CONTRACTOR TO VERIFY <br />EACH CONDITION WITH THE PRODUCT MANUFACTURER OR SUPPLIER AND/OR LOCAL <br />JURISDICTION FOR THEIR REQUIREMENTS PRIOR TO SUBMITTING A BID TO THE <br />OWNER OR PROCEEDING WITH WORK. <br />THE ITEMS OUTLINED BELOW ARE NOT INTENDED TO BE AN EXHAUSTIVE ANALYSIS OF <br />ALL POSSIBLE AREAS OF CONCERN OR CONFLICT, BUT RATHER SERVE AS A <br />BEGINNING POINT IN IDENTIFYING COMMONLY OVERLOOKED AREAS IN THE <br />CONSTRUCTION PROCESS. <br />1. REVIEW MANUFACTURER'S PRODUCT LITERATURE FOR INSTALLATION <br />INSTRUCTIONS UNIQUE TO THE PROJECT CONSTRUCTION TYPE. <br />A. GAS APPLIANCES AND CHASE REQUIREMENTS <br />B. HVAC EQUIPMENT AND DUCTING <br />C. ALL EXHAUST FANS AND DUCTING <br />D. BATHTUB AND SHOWER ENCLOSURES <br />E. RECESSED AND SEMI -RECESSED ELECTRICAL EQUIPMENT <br />F. RECEPTACLE BOXES (I.E.: TELEVISION, TELEPHONE, ELECTRICAL, <br />PLUMBING) <br />G. ANY OTHER BUILT-IN OR RECESSED EQUIPMENT WHICH MAY <br />PENETRATE A FLOOR/CEILING, ROOF/CEILING OR WALL ASSEMBLY. <br />2. REVIEW LOCAL JURISDICTIONAL REQUIREMENTS FOR COMPLETE <br />INSTALLATIONS OF THE FOLLOWING: <br />A. BUILDING FIRE ALARM SYSTEM (NFPA 72) <br />B. FIRE EXTINGUISHER SIZE, TYPE AND LOCATION <br />C. FIRE SUPPRESSION SPRINKLER SYSTEM - VERIFY NFPA SYSTEMS <br />D. EMERGENCY AND EXIT LIGHTING <br />3. COORDINATE WITH THE FOLLOWING UTILITIES AND COMPLY WITH LOCAL <br />JURISDICTIONAL REQUIREMENTS: <br />A. TELEPHONE UTILITY <br />B. CABLE TELEVISION UTILITY <br />C. POWER UTILITY, VAULT AND EASEMENTS <br />D. GAS UTILITY <br />E. TRASH SERVICE AND RECYCLING SERVICE <br />F. POSTAL AUTHORITY <br />G. DEPARTMENT OF PUBLIC WORKS FOR: <br />I. SANITARY SEWER <br />ii. STORM SEWER <br />iii. WATER SUPPLY <br />4. THE FOLLOWING ITEMS SHALL BE BIDDER DESIGN/BUILD SYSTEMS. THE SUB- <br />CONTRACTOR SHALL PROVIDE A COMPLETE SYSTEM TO THE OWNER WHICH <br />COMPLIES WITH ALL JURISDICTIONAL REQUIREMENTS: <br />A. FIRE SPRINKLER SYSTEM <br />B. FIRE ALARM SYSTEM <br />C. SMOKE EVACUATION SYSTEM <br />D. ELECTRICAL <br />E. PLUMBING <br />F. MECHANICAL <br />THE BIDDER DESIGN/BUILD SYSTEMS SHALL BE SUBMITTED TO THE <br />APPROPRIATE JURISDICTION(S) FOR REVIEW AND APPROVAL. <br />5. SUBCONTRACTORS SHALL PROVIDE DETAILS AND INFORMATION TO THE LOCAL <br />JURISDICTION FOR APPROVAL SHOWING HOW PENETRATIONS OF FIRE - <br />RESISTANCE RATED ASSEMBLIES (WALLS, FLOORS & CEILINGS) ARE PROTECTED. <br />PROVIDE 7" AND/OR "T" RATINGS FOR BOTH MEMBRANE & THROUGH <br />PENETRATIONS, ALONG WITH APPROPRIATE APPROVAL NUMBERS FOR PROPOSED <br />FIRESTOPPING SYSTEMS. <br />co <br />W <br />0 <br />co <br />le <br />CD <br />W <br />J <br />m <br />Q <br />ALLOWED <br />PROPOSED <br />V-A 1HR <br />LEVEL 6 <br />70' ABOVE <br />68.4' <br />CONSTRUCTION <br />GRADE <br />(FROM GRADE PLANE) <br />R2 <br />LEVEL 5 <br />PLANE <br />LEVEL4 <br />OCCUPANCY <br />a <br />75' ABOVE AV. <br />73.05' <br />Z <br />LEVEL 3 <br />BASE <br />(FROM AVERAGE BASE <br />LEVEL 2 <br />ELEVATION <br />ELEVATION) <br />3 HR HORIZONTAL SEPARATION PER IBC 510.2 <br />10.5' <br />(FROM GRADE PLANE) <br />1-A <br />CONSTRUCTION <br />LEVEL1 <br />a <br />UL <br />15.7' <br />u_ <br />(FROM AVERAGE BASE <br />Z <br />OCCUPANCY <br />ELEVATION) <br />ALLOWED I PROPOSED <br />V-A 1HR <br />LEVEL 6 <br />CONSTRUCTION <br />*4+1 <br />*5 <br />LEVEL 5 <br />STORIES <br />STORIES <br />LEVEL 4 <br />R2 <br />ABOVE <br />ABOVE <br />a <br />OCCUPANCY <br />HORIZONTAL <br />HORIZONTAL <br />U_ <br />LEVEL 3 <br />SEPARATION <br />SEPARATION <br />Z <br />LEVEL 2 <br />3 HR HORIZONTAL SEPARATION PER IBC 510.2 <br />1-A <br />CONSTRUCTION <br />LEVEL 1 <br />UL <br />1 STORY <br />a. <br />S-2,13,A-3,A-4 <br />Z <br />OCCUPANCY <br />SEE CALCULATIONS <br />w <br />BELOW FOR GRADE <br />PLANE, AVERAGE FINAL <br />GRADE, AND BUILDING <br />a <br />HEIGHT. <br />a <br />w <br />C9 LU <br />ZZ <br />Y uJ <br />� U <br />a� <br />aW <br />w <br />Z <br />w <br />H <br />a <br />a <br />a <br />w <br />�w <br />Z Z <br />Y uJ <br />� U <br />a� <br />aW <br />w <br />* PRESSURIZED STAIR INCREASE (IBC 504.4.1): <br />WAC CHAPTER 51-50 AMENDMENTS TO 2015 WASHINGTON STATE BUILDING CODE <br />SECTION 504.4.1 ALLOWS AN INCREASE OF 1 (ONE) STORY FROM THE ALLOWABLE <br />MAXIMUM PROVIDED THAT THE INTERIOR EXIT STARWAYS AND RAMPS <br />ARE PRESSURIZED IN ACCORDANCE WITH SECTION 909. <br />ALLOWED <br />PROPOSED <br />ALLOWED <br />PROPOSED <br />~ <br />X <br />BUILDING EXTERIOR TOTAL <br />RATIO <br />BUILDING EXTERIOR TOTAL <br />RATIO <br />AREAS COVERED AREAS PER FLOOR <br />LU <br />AREAS COVERED AREAS PER FLOOR <br />VA 1HR <br />LEVEL 6 <br />20,064 SF <br />116 SF <br />20,180 SF <br />.44 <br />VA 1HR <br />LEVEL 6 <br />873 SF <br />220 SF <br />1,093 SF <br />.2 <br />CONSTRUCTION <br />P = <br />ZO <br />CONSTRUCTION <br />= <br />LEVEL 5 <br />20,064 SF <br />116 SF <br />20,180 SF <br />.44 <br />w <br />N <br />LEVEL 5 <br />873 SF <br />220 SF <br />1,093 SF <br />.2 <br />w <br />R2 <br />45,000 SF MAX <br />p <br />R2 <br />45,000 SF MAX <br />a ~ <br />LEVEL 4 <br />20,064 SF <br />116 SF <br />20,180 SF <br />.44 <br />LEVEL 4 <br />873 SF <br />220 SF <br />1,093 SF <br />.2 <br />OCCUPANCY <br />PER FLOOR <br />W 0 <br />= <br />OCCUPANCY <br />PER FLOOR <br />LL <br />LEVEL 3 <br />20,064 SF <br />116 SF <br />20,180 SF <br />.44 <br />a Z <br />w <br />LEVEL 3 <br />873 SF <br />220 SF <br />1,093 SF <br />.2 <br />Z a 0 <br />a <br />a <br />LEVEL 2 <br />20,064 SF <br />116 SF <br />20,180 SF <br />.44 <br />N <br />LEVEL 2 <br />873 SF <br />220 SF <br />1,093 SF <br />2 <br />100,900 SF <br />2.2 <br />3 HR HORIZONTAL SEPARATION PER IBC 510.2 <br />5,465 <br />1.4 <br />1-A <br />w <br />CONSTRUCTION <br />LEVEL 1 <br />UL <br />30,069 SF <br />661 SF <br />30,730 SF <br />LU <br />z Z <br />S2, A-3, A-4, B <br />z <br />a �? <br />OCCUPANCY <br />11.0 <br />w <br />TYPE V-A ALLOWABLE BUILDING AREA: 36,000 SF (At) I APARTMENTS NORTH I TYPE V-A ALLOWABLE BUILDING AREA: 36,000 SF (At) I APARTMENTS SOUTH <br />BUILDING AREA CALCULATIONS (IBC 506.2.3): BUILDING AREA CALCULATIONS (IBC 506.2.3): <br />UPPER LEVEL BUILDING TYPE V-A/ SPRINKLERED (SM) / LEVELS 2-6: UPPER LEVEL BUILDING TYPE V-A/ SPRINKLERED (SM) / LEVELS 2-6: <br />TYPE V-A ALLOWABLE BUILDING AREA: 36,000 SF (At) per Story TYPE V-A ALLOWABLE BUILDING AREA: 36,000 SF (At) per Story <br />Aa = {At + (NS x I f)} x Sa Aa = {36,000 + (12,000 x 1)} x 3 = 144,000 SF Aa = {At + (NS x I f)} x Sa Aa = {36,000 + (12,000 x .3)} x 3 = 115,200 SF <br />Aa = Allowable area (SF) At = Tabular allowable area factor Aa = Allowable area (SF) At = Tabular allowable area factor <br />NS = Tabular area factor per table 506.2 for non-sprinklered building NS = Tabular area factor per table 506.2 for non-sprinklered building <br />If = Area factor increase due to frontage (percentage) per 506.3 SEE CALCULATIONS ON If = Area factor increase due to frontage (percentage) per 506.3 SEE CALCULATIONS ON <br />CS02B If = 1 CS02B If = 1 <br />Sa = Actual number of building stories above grade plane, not to exceed 3. Sa = Actual number of building stories above grade plane, not to exceed 3. <br />NO STORY SHALL EXCEED THE ALLOWABLE BUILDING AREA PER STORY = 39,960 SF NO STORY SHALL EXCEED THE ALLOWABLE BUILDING AREA PER STORY = 39,960 SF <br />ACTUAL AREA: 106,365 SF LARGEST ACTUAL STORY: 20,180 SF ACTUAL AREA: 5,465 SF LARGEST ACTUAL STORY: 1,093 SF <br />NOTE: BUILDING AREA ALSO COMPLIES WHEN CALCULATED AS A MIXED -OCCUPANCY MULTI -STORY NOTE: BUILDING AREA ALSO COMPLIES WHEN CALCULATED AS A MIXED -OCCUPANCY MULTI -STORY <br />STRUCTURE PER 506.2.4. AGGREGATE SUM OF THE RATIOS IS < 3.0. SEE CALCULATIONS ABOVE. STRUCTURE PER 506.2.4. AGGREGATE SUM OF THE RATIOS IS < 3.0. SEE CALCULATIONS ABOVE. <br />SITE DIAGRAM: GRADE PLANE, BUILDING HEIGHT CALCULATIONS <br />BUILDING HEIGHT (IBC CHAPTER 2): THE <br />VERTICAL DISTANCE FROM GRADE PLANE TO <br />THE AVERAGE HEIGHT OF THE HIGHEST ROOF <br />SURFACE - SEE BUILDING ELEVATIONS FOR \ <br />DIMENSIONS. <br />GRADE PLANE (IBC CHAPTER 2): A REFERENCE <br />PLANE REPRESENTING THE AVERAGE OF <br />FINISHED GROUND LEVEL ADJOINING THE <br />BUILDING AT EXTERIOR WALLS. GRADE SLOPES <br />UNIFORMLY ALONG EXTERIOR WALL. <br />BUILDING HEIGHT IBC TABLE 503.4 <br />GRADE PLANE: 570.05' <br />AVERAGE RIDGE (HIGHEST) 637.8' <br />BUILDING HEIGHT (IBC): 68.4' <br />I <br />CITY OF EVERETT ZONING CODE CHAPTER 6 <br />AVERAGE BASE ELEVATION IS COMPOSED OF THE <br />AVERAGE OF THE ELEVATIONS AT THE MIDPOINTS <br />AT THE FOUR SIDES OF A RECTANGLE <br />ENCOMPASSING THE ENTIRE BUILDING <br />AVERAGE BASE ELEVATIONS CALCULATIONS <br />POINT A: <br />562.19' <br />POINT B: <br />545.5' <br />POINT C: <br />568.02' <br />POINT D: <br />569.84' <br />AVERAGE BASE ELEVATION: <br />565.31' <br />AVERAGE RIDGE (HIGHEST) <br />637.8' <br />BUILDING HEIGHT (ZONING) <br />72.5' <br />SEE EXTERIOR ELEVATIONS <br />M <br />GRADE PLANE CALCULATION <br />ELA <br />EL.2 <br />L <br />(EL.1+EL.2/2)*L <br />WALL 1 <br />570.3 <br />570.46 <br />234 <br />133,469 <br />WALL 2 <br />570.46 <br />567.47 <br />90.5 <br />51,491 <br />WALL 3 <br />567.97 <br />567.97 <br />14.7 <br />8,349 <br />WALL 4 <br />567.97 <br />567.86 <br />33.8 <br />19,196 <br />WALL 5 <br />567.97 <br />567.86 <br />38.8 <br />22,035 <br />WALL 6 <br />567.86 <br />567.88 <br />109.2 <br />62,011 <br />WALL 7 <br />567.88 <br />567.88 <br />43.6 <br />24,760 <br />WALL 8 <br />567.88 <br />570 <br />27.2 <br />15,477 <br />WALL 9a <br />570.65 <br />570.65 <br />75.2 <br />42,912 <br />WALL 9b <br />570.65 <br />570 <br />31.3 <br />15.65 <br />WALL 10 <br />570.65 <br />569.83 <br />44.4 <br />25,316 <br />WALL 11 <br />569.83 <br />570.15 <br />19.2 <br />10,943 <br />WALL 12 <br />570.15 <br />570.15 <br />257.25 <br />147,228 <br />WALL 13 <br />570.15 <br />570.30 <br />65.3 <br />37,234 <br />TOTALS <br />1,089.2 <br />620,786 <br />GRADE PLANE ELEVATION = <br />570.05' <br />POINT A <br />li 562.19' <br />570.30' <br />WALL 1 234'-0" <br />LEVEL 1 FFE 570.5' <br />LEVEL 2 FFE 581.0' <br />� 570.15' <br />WALL 12 257'-3" <br />POINT B 567.97' <br />545.5' <br />WALL 5 <br />J O <br />J 38'-10" <br />M <br />567.97' <br />WALL 3 <br />14'-8" <br />570.46' <br />567.86' <br />.97' <br />0 <br />OHNSON BRAUNDINC. <br />15200 52nd Ave. South <br />Suite 300 <br />Seattle, WA 98188 <br />Phone 206.766.8300 <br />www.johnsonbraund.com <br />ARCHITECTURE <br />INTERIOR DESIGN <br />Greg L. Allwine, <br />Jeffrey A. Williams, <br />8556 <br />REGISTERED <br />ARCHITECT <br />WFFREY THUR WILLIAM <br />STATE OF WASHINGTON <br />STAMP <br />Q <br />0m <br />�U) <br />U)� <br />LULU <br />ww <br />o <br />a <br />LU <br />0 <br />N <br />W <br />Q <br />o <br />CO <br />o <br />a <br />N <br />d <br />0 <br />d <br />a <br />0 <br />d <br />b <br />0 <br />w <br />0 <br />a <br />Uj <br />w <br />_ <br />0 <br />r <br />z <br />< <br />z <br />0 <br />w <br />co <br />0 <br />Uj <br />w <br />0 <br />z <br />w <br />z <br />0 <br />z <br />w <br />< <br />w <br />t Q= <br />E0 <br />Ez <br />C� <br />z <br />L0 <br />M < <br />O m <br />F o <br />00 <br />A+ o <br />W w � �o <br />N < <br />LU <br />L w Z a <br />< <br />QUUo L� <br />U wF <br />J J (n O � w <br />d ��� z> <br />567.88' L o Q w <br />Q W Cj Z o ~ <br />W Z L C) a) LU <br />Cl) <br />LL cn O LL m a <br />I <br />\568.00' <br />0 <br />V67,88��% <br />I <br />O <br />o <br />_ <br />13 <br />POINT C <br />568.02' <br />2 HR <br />00 <br />SEPARATION <br />13Q <br />PROJECT #: 1827 <br />WALL <br />o <br />DRAWN BY: SK <br />WALL 9b <br />31'-3" <br />570.0' <br />CHECKED BY: ST <br />Lo <br />570.65' <br />BLDG B - CODE <br />COMPLIANCE <br />- 570.15' <br />Q N WALL 10 CS01 B <br />PERMIT SET 10/09/2020 <br />POINT D 569.83' 570.65' <br />569.84' <br />