My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
8102 EVERGREEN WAY EVERETT 4 CORNERS - BLDG B 2025-08-22
>
Address Records
>
EVERGREEN WAY
>
8102
>
EVERETT 4 CORNERS - BLDG B
>
8102 EVERGREEN WAY EVERETT 4 CORNERS - BLDG B 2025-08-22
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2025 11:16:45 AM
Creation date
7/29/2025 6:29:44 AM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
8102
Tenant Name
EVERETT 4 CORNERS - BLDG B
Imported From Microfiche
No
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
1616
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
o_ <br />M <br />GENERAL NOTES <br />N <br />0 1. SEE SITE PLAN FOR ACTUAL AND ASSUMED PROPERTY LINES INCLUDING THOSE REQUIRED BY <br />N 2015 IBC SECTION 705.3. ALL BUILDINGS MINIMUM FIRE SEPARATION DISTANCE = 30'-0". <br />N <br />N <br />2. 3 HR FLOOR/CEILING ASSEMBLY <br />- SEE BUILDING SECTION & HORIZONTAL ASSEMBLY DETAILS ON SHEET A040, A041. <br />3. TABLE 705.8 ALLOWS 45% OF WALL AREA TO HAVE UNPROTECTED OPENINGS IN R-2, <br />SPRINKLERED BUILDINGS WITH A FIRE SEPARATION DISTANCE FROM 10 FEET TO LESS <br />THAN 15 FEET. <br />4. MEANS OF EGRESS /CORRIDOR: <br />IBC SECTION 1020.2 THE MINIMUM WIDTH OF CORRIDOR SPECIFIED IN TABLE 1020.2 <br />SHALL BE AS DETERMINED IN IBC SECTION 1005.1. <br />STAIR: <br />IBC SECTION 1011.2 THE WIDTH OF STAIRWAYS SHALL BE DETERMINED AS <br />SPECIFIED IN IBC SECTION 1005.1, BUT SUCH WIDTH SHALL NOT BE LESS THAN 44". <br />SEE IBC SECTION 1009.3 FOR ACCESSIBLE MEANS OF EGRESS STAIRWAYS. <br />SEE STAIR SECTIONS REFERENCED PER BUILDING BELOW FOR EMERGENCY LIGHT FIXTURE LOCATION. <br />BLDG A SEE SHEETS A480 & A481 <br />BLDG B SEE SHEETS A481 & A482 <br />BLDG C&D SEE SHEETS A481 <br />MEANS OF EGRESS <br />1. AREAS INCLUDED FOR OCCUPANT LOAD CALCULATION DO NOT INCLUDE <br />CORRIDORS, STAIRS, RESTROOMS AND UNOCCUPIED AREAS. <br />2. THE NUMBER OF OCCUPANTS HAVE BEEN ROUNDED UP. <br />3. DESIGN OCCUPANT LOAD PER IBC TABLE 1004.1.2: SEE CALCS. BY OCCUPANCY ON <br />THIS SHEET. <br />A. STORAGE, BUILDING SERVICES & MECH. ROOM = 300 SF / OCCUPANT (GROSS) <br />B. RESIDENTIAL = 200 SF / OCCUPANT (GROSS) <br />5. NUMBER OF EXITS (IBC SECTION 1006): TWO EXITS SHALL BE REQUIRED FROM ANY <br />SPACE WHERE THE OCCUPANT LOAD EXCEED THE FOLLOWING VALUES PER IBC TABLE <br />1006.2.1: SEE EXITING PLAN ON THIS SHEET. <br />6. SEPARATION OF EXITS (IBC SECTION 1007.1.1): WHERE TWO EXITS ARE REQUIRED <br />THEY SHALL BE PLACED A DISTANCE APART EQUAL TO NOT LESS THAN 1/2 THE CON <br />DIAGONAL DIMENSION OF THE AREA SERVED. SEE EXITING PLANS ON THIS SHEET FOR 5 <br />SEPARATION DIMENSIONS. 3 <br />7. COMMON PATH OF EGRESS TRAVEL (IBC TABLE 1006.2.1): <br />A. 100' MAX GROUP S-2 WITH OCCUPANT LOADS OVER 30 (SPRINKLERED BUILDING) <br />B. 125' MAX GROUP R-2 WITH OCCUPANT LOADS OVER 30 (SPRINKLED BUILDING) <br />9. EXIT ACCESS TRAVEL DISTANCE (IBC SECTION 1017): <br />A. GROUP S-2 = 400 FT (SPRINKLERED) <br />B. GROUP R-2 = 250 FT (SPRINKLERED) <br />10. DEAD-END CORRIDORS (IBC SECTION 1020.4. EXCEPTION #2 <br />2. IN OCCUPANCIES GROUPS R-2 AND S-2 WHERE THE BUILDING IS EQUIPPED <br />THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM IN <br />ACCORDANCE WITH SECTION 903.3.1.1, THE LENGTH OF THE DEAD-END CORRIDORS <br />SHALL NOT EXCEED 50 FEET. <br />11. EGRESS WIDTH (IBC SECTION 1005.3.2, EXCEPTION): SHALL NOT BE LESS THAN <br />THE TOTAL OCCUPANT LOAD SERVED BY THE MEANS OF EGRESS MULTIPLIED BY: <br />A. .15 INCHES PER OCCUPANT FOR OTHER COMPONENTS (SPRINKLERED) <br />PROPOSED 36" DOOR = 34"/.15 = 226 OCCUPANTS ACCOMMODATED <br />B. SEE EXITING PLANS FOR ACTUAL NUMBER OF OCCUPANTS AT EACH DISCHARGE. <br />12. MEANS OF EGRESS ILLUMINATION (IBC SECTION 1008): <br />A. ILLUMINATION SHALL BE PROVIDED AT EVERY POINT IN THE MEANS OF EGRESS. THE <br />ILLUMINATION LEVEL SHALL NOT BE LESS THAN 1 FOOT-CANDLE (11 LUX) AT THE <br />WALKING SURFACE AT ALL TIMES THE SPACE SERVED BY THE MEANS OF EGRESS IS <br />OCCUPIED. LUMINARIES SHALL BE INSTALLED WHENEVER EXIT SIGNS ARE <br />REQUIRED. <br />B. POWER SUPPLY TO BE PROVIDED BY PREMISES' ELECTRICAL SUPPLY. IN EVENT OF <br />POWER SUPPLY FAILURE, AN EMERGENCY POWER SYSTEM SHALL AUTOMATICALLY <br />ILLUMINATE AREAS REQUIRED PER IBC SECTION 1008.3 INCLUDING: CORRIDORS, <br />EXIT ENCLOSURES, EXIT PASSAGEWAYS, INTERIOR EXIT DISCHARGE ELEMENTS AND <br />EXTERIOR LANDINGS FOR EXIT DISCHARGE DOORWAYS. <br />C. EMERGENCY POWER SYSTEM SHALL PROVIDE POWER FOR A DURATION OF <br />NOT LESS THAN 90 MINUTES AND SHALL CONSIST OF STORAGE BATTERIES, UNIT <br />EQUIPMENT OR AN ON -SITE GENERATOR. REFER TO ELECTRICAL BIDDER/DESIGN <br />PLANS FOR SYSTEM DESIGN. <br />13. EXIT SIGNS (IBC SECTION 1013 <br />A. PROVIDE AN APPROVED EXIT SIGN AT ALL EXITS AND EXIT ACCESS DOORWAYS <br />(FROM SPACES REQUIRING TWO EXITS) IN A LOCATION THAT IS READILY VISIBLE <br />FROM ANY DIRECTION OF EGRESS TRAVEL. PLACE SIGNS SUCH THAT NO POINT <br />IN CORRIDOR OR EXIT PASSAGEWAY IS MORE THAN 100 FT FROM THE NEAREST <br />VISIBLE EXIT SIGN. SEE BUILDING PLANS FOR SIGN LOCATIONS. <br />B. EXIT SIGNS SHALL BE INTERNALLY OR EXTERNALLY ILLUMINATED PER IBC <br />SECTION 1013.5 AND 1013.6 <br />C. PROVIDE A TACTILE EXIT SIGN STATING "EXIT" AND COMPLYING WITH ICC <br />A117.1-2009 ADJACENT TO EACH DOOR TO AN AREA OF REFUGE, EXTERIOR <br />AREA FOR ASSISTED RESCUE, EXIT STAIRWAY, EXIT RAMP, EXIT PASSAGEWAY <br />AND EXIT DISCHARGE. <br />OCCUPANTLOAD <br />OCCUPANTS <br />EXITS <br />LEVEL 6 <br />98 <br />2 <br />X <br />LEVEL 5 <br />98 <br />2 <br />a) <br />LEVEL 4 <br />98 <br />2 <br />cal <br />LEVEL 3 <br />98 <br />2 <br />ZI <br />LEVEL 2 <br />98 <br />3 <br />LEVEL 1 <br />106 <br />2 <br />b <br />TOTAL <br />596 <br />C) <br />U <br />ONLY 2 EXITS ARE REQUIRED AS NO INDIVIDUAL STORY HAS > 500 OCCUPANTS PER TABLE 1006.3.1 <br />I <br />L <br />a) <br />L <br />O <br />U <br />L <br />O <br />LL. <br />I` <br />00 EGRESS LEGEND <br />a) # <- OCCUPANT LOAD PER EXIT <br />E <br />0 0 DOOR EGRESS WIDTH STAIR EGRESS WIDTH <br />TOTAL NUMBER OF OCCUPANTS SERVED TOTAL # OF OCCUPANTS SERVED <br />0 REQUIRED DOOR WIDTH (.2) 0 REQUIRED STAIR WIDTH (.2) <br />x PROVIDED DOOR WIDTH PROVIDED STAIR WIDTH <br />gMAXIMUM EXIT ACCESS TRAVEL DISTANCE TO NEAREST EXIT (250' PER TABLE 1017.2) <br />MAXIMUM COMMON PATH OF EGRESS TRAVEL (125' PER TABLE 1006.2.1) <br />U) <br />EXIT RAISED CHARACTER & BRAILLE EXIT SIGN PER IBC SECTION 1011.4 <br />U <br />F.E.C. FIRE EXTINGUSHER CABINET SEE DETAITYPE 5LB AC <br />SIZE 2A 10BC <br />6j <br />ACCESSIBLE <br />2 <br />ELEVATOR TO <br />MEANS OF <br />* <br />z <br />O ACCOMMODATE <br />EGRESS <br />w <br />STRETCHER <br />ELEVATOR <br />J_ <br />U_ <br />70'-4" LONGEST COMMON PATH <br />OF EGRESS DISTANCE <br />LEVEL 1 - BLDG B <br />1 " = 20'-0" <br />ADCA nC IAI(`DCACC TAQI II ATVlA1C QI III MlAlf_ 0 <br />.6/30 <br />STAIR 1 <br />CONVERGEN <br />7 <br />48" <br />h� <br />W <br />Z <br />W <br />Lu <br />CIO <br />Z <br />0 <br />N <br />� <br />o <br />o _ Q <br />O <br />co <br />co <br />A J a <br />II QLu <br />N <br />c) IF <br />coc')ILL <br />z <br />I STAIR 3 <br />C <br />48" <br />300 <br />EN <br />65' - 4" RAGE <br />FSD = > 30' _0" 70 SF 300 GROSS <br />WALL 7 1 OCC 1 EXIT <br />RESIDENTIAL UNITS <br />R-2 <br />2184 SF 200 GROSS <br />11 OCC 1 EXIT F-Nr <br />75' - 11 1 /2" <br />FSD = > 30'-0" <br />WALL 5 <br />EXIT <br />S-2 <br />133 SF 200 <br />O <br />1 Occ rr <br />0 <br />10'-5" <br />1 <br />2 <br />3 <br />4 <br />TACTILE EXIT SIGN <br />18" MIN. CLR FLR SPACE CENTERED <br />ON TACTILE CHARACTERS <br />4" <br />M ao : ILL: <br />M U_ <br />... Q <br />- Q <br />0 <br />N � <br />z <br />NOTES: <br />00 <br />4" WIDE x 3" HIGH x 1/8" THICK SIGN MOUNTED AT STRIKE SIDE <br />OF EXIT DOORS. <br />LETTER CHARACTERS TO BE RAISED 1/32" x 7/8" HIGH UPPER <br />CASE, SAN SERIF TYPE AND ACCOMPANIED BY GRADE 2 <br />ROUNDED OR DOMED SHAPED BRILLE. <br />BRAILLED CHARACTERS TO CONFORM WITH STANDARD <br />DIMENSIONS FOR LITERARY BRAILLE AND AS INDICATED IN <br />2009 ICC/ANSI A117.1 703.3. <br />LOCATE SIGN AT EACH REQUIRED EXTERIOR EXIT DOOR. <br />(EXTERIOR DOORS WITH ILLUMINATED EXIT SIGN ABOVE.) <br />1184' 8" LONGEST EXIT <br />ACC ESS TRAVEL <br />DISTANCE <br />LONGEST COMMON PATH OF <br />EG REES TRAVEL 75'-2" <br />MECHANICAL 82' - 10 7/8" C) <br />LO <br />114 SF 300 GR DSS FSD = > 25'-0" N <br />1 OCC 1 EXIT WALL 2 <br />RESIDENTIAL UNITS <br />R-2 <br />1971 SF 200 GROSS <br />10 OCC 1 EXIT FIF. <br />RESIDENTIAL UNITS <br />R-2 <br />2710 SF 200 GROSS <br />14 OCC 1 EXIT P/ <br />� • �%���r7�II <br />aI I <br />1 III 'Ii ��-���ii;�� • <br />STOP <br />�45S <br />ORAGE <br />S-2 S-2 <br />81 SF 300 GROS F 300 GF1 OCC 1 EXI C 1 EXIT <br />83' - 6"�i1IK///�r/z <br />SEPARATION BETWEEN <br />0 <br />0 0 0 <br />99, - 2" <br />\ FSD = > 30'-0" <br />/ WALL 4 <br />HORIZONTAL EXIT <br />FOR BUILDING B <br />APARMENTS SOUTH / <br />2HR SEPARATION WALL <br />®r <br />OHNSON BRAUNDINC. <br />15200 52nd Ave. South <br />Suite 300 <br />Seattle, WA 98188 <br />Phone 206.766.8300 <br />www.johnsonbraund.com <br />ARCHITECTURE <br />INTERIOR DESIGN <br />Greg L. Allwine, <br />Jeffrey A. Williams, <br />8556 <br />REGISTERED <br />ARCHITECT <br />J FFREY ARTHUR WILLIAM <br />STATE OF WASHINGTON <br />STAMP <br />Q <br />Z <br />� <br />OCie <br />�U) <br />c <br />o <br />a_ <br />LU <br />0 <br />N <br />W <br />Q <br />o <br />in <br />p <br />o <br />c <br />0 <br />EL <br />�L <br />N <br />d <br />0 <br />U) <br />z <br />z <br />w <br />75 <br />0 <br />U <br />w <br />EL <br />N <br />N <br />0 <br />� <br />M <br />d <br />U <br />w <br />0 <br />a <br />LU <br />w <br />0 <br />r <br />z <br />a <br />z <br />O <br />w <br />U) <br />O <br />LL <br />V/ <br />0 <br />p <br />LU <br />z <br />w <br />z <br />0 <br />z <br />�w <br />Q <br />w <br />Q= <br />Q~ <br />a <br />Ez <br />C� <br />z <br />Q\ <br />M <br />L Q <br />m <br />N <br />C) <br />00 <br />Fo <br />L <br />Q <br />cjeZ <br />LL Oc <br />A+ <br />W <br />> <br />w <br />o <br />�o <br />L <br />00 W <br />Q <br />0 <br />z = <br />o <br />a- Q <br />LU� <br />U <br />00 <br />J J (n a)� <br />LULU <br />w <br />a �Q <br />z> <br />L <br />o <br />Q =� <br />wz <br />az <br />Q <br />WU <br />o� <br />W <br />z C) (1) <br />7 <br />LU <br />�- <br />11 <br />w <br />O li ( pp <br />a <br />PROJECT #: 1827 <br />DRAWN BY: SK <br />BLDG B - CODE <br />SUMMARY AND <br />OCCUPANCY <br />CS02B <br />PERMIT SET 10/09/2020 <br />
The URL can be used to link to this page
Your browser does not support the video tag.