Q <br />SHEET NOTES <br />Lp <br />1. LEVELS 2-6 TYPE VA CONSTRUCTION <br />LO <br />co <br />�V <br />R2 OCCUPANCIES <br />N <br />OHNSON BRAUNDINC. <br />o <br />N <br />N <br />2. <br />15200 52nd Ave. South <br />IBC SECTION 903.3.1.1 (NFPA 13). <br />Suite 300 <br />0 <br />3 REFER TO SHEETS CS03 FOR FIRE <br />Seattle, WA 98188 <br />ASSEMBLY KEY PLAN W/ WALL TYPE <br />Phone 206.766.8300 <br />TAGS & LOCATIONS. REFER TO <br />www.johnsonbraund.com <br />SHEET SERIES A040 FOR ASSEMBLY <br />A R C H I T E C T U R E <br />DETAILS. <br />INTERIOR DESIGN <br />4. SEE ENLARGED UNIT PLANS FOR ALL <br />Greg L. Allwine, <br />INTERIOR DIMENSIONS, WINDOW AND <br />Jeffrey A. Williams, <br />DOOR CALL -OUTS, AND RATED WALL <br />TAGS <br />5. EXIT STAIR ENCLOSURES IN TYPE 1A <br />CONSTRUCTION SHALL BE 3-HOUR <br />RATED <br />ALL VERTICAL SHAFTS SHALL BE 2- <br />6' HOUR RATED PER IBC SECTION 713.4. <br />7. ODOOR TYPE - SEE SCHEDULE <br />SHEET A100 <br />8. REFER TO SHEET SERIES A100 FOR <br />8556 <br />UNIT PLAN DOOR & WINDOW <br />REGISTERED <br />SCHEDULE. <br />ARCHITECT <br />9. REFER TO SHEETS Al 10, A120, <br />eFFREY <br />A130, A140, A150 & A151 FOR <br />THUR WILLIAMENLARGED <br />UNIT PLANS. <br />WASH NCTON <br />10. REFER TO ACCESSIBILITY NOTES <br />STAMP <br />ON SHEET CS00 <br />11. PROVIDE MECHANICALLY <br />B.b B.0 B.d B.e B.f B. FASTENED INSULATION AT ALL <br />g CEILINGS BETWEEN CONDITIONED <br />7 AND UNCONDITIONED SPACE, <br />REFER TO SHEET A040 FOR <br />REQUIRED R-VALUES. <br />UNI 2.1 <br />51 g I I 7A _ 12. CORRIDOR VENTILATION CONCEPT <br />N U SHOWN, REFER TO DESIGN/BUILD <br />SHEET A120 I Uj � MECHANICAL PLANS. <br />� <br />ui <br />1 LL72 N <br />B.3 - - - - I - - - I - - - - B.3 13. CABINET <br />F.E.0 RECESSED/FIRE EXTINGUISHER <br />% <br />SEE DETAIL: 6 <br />3'-0" 2'-0" II I <br />B.h A051 <br />_ I_ <br />N II II o o -i- 7D N <br />o c, 4 14. F.E. <br />E EXTINGUISHER CABINET <br />I 7C I <br />A423 LOCATE PER IBC TABLE 906.3 <br />UNIT 1.1 - I (1) 75 FT. MAX. SEPARATION - <br />o PARKING GARAGE LEVEL ONLY <br />It Q 518 o SEE DETAIL 3/A051 FOR <br />( I <br />_SHEET Al 10 MOUNTING/INSTALLATION <br />1 2 A323 <br />C _ HEIGHT <br />�7D I 1 I 1 / / 1 15. EXIT SIGN PER IBC SECTION 1013. <br />A322CD <br />N 16. REFER TO DESIGN/BUILD <br />9 1 /2' 25' - 11 " 1 " 45' - 10 1 /2" 2 4" 10' - 0 1 /8" 01 6' - 2 5/8" / ELECTRICAL PLANS. <br />B.a II u II I <br />00 2'-01 II -- 01 10'-0" 3'-21/ " 12'-9" 10'-8" 9'-101/2" / 1 17. REFER TO SHEETA051 FOR <br />Q <br />M <br />o <br />0 <br />m <br />D <br />a <br />U) <br />LULU <br />w; <br />0 <br />0 <br />w <br /><Q <br />Uo0 <br />EL <br />N <br />d <br />0 <br />d <br />a <br />0 <br />d <br />0 2 Sim PENETRATION REQUIREMENTS IN <br />A483 7A 7A 3 / FIRE RATED CONSTRUCTION. <br />O - - _ _ _ _ _ _ - _ - _ A480 / 18. REFERENCE BUILDING ENVELOPE w <br />- I=Pr 4 / I DRAWINGS FOR ALL WATERPROOFING. a <br />UNI 2.1 7C / w <br />517 SHAFT I 11 3/4" 7 J I / 19 INDICATES TYPE A ACCESSIBLE UNIT. o <br />SHEET A120 F_ - LEV #1 ALL REMINING UNITS SHALL MEET TYPE z <br />1 7B2 - I I B ACCESSIBLE UNIT REQUIREMENTS Q <br />/ _ I PER IBC SECTION 1107.6.2 0 <br />cl) z <br />LEV-1 <br />2 ILU <br />-4 1-�� - 7C - � 24 - 7D - - - - 7 - - - - - - - - 7 � - �- - - - - - - - UNIT DEMISING WALLS ARE 1 HOUR co <br />� <br />N ET _ ° o STORAGE I I 17K _ _ - - <br />6„ S-500 SHEET _ _ - - / 20. RATED PER IBC SECTION 708 W/ <br />N 7C VFY 21 NOTE #24 I 7J I I _ _ _ _ _ I / MINIMUM STC 50. SEE SHEETS A040&A041 N w <br />0 <br />II I LOBBY 24 LEV #2 LU <br />!Hill <br />OOELEV-2 - - - UNIT 1.1 UNIT 3.1 _ _ - - 21. ® INDICATES TYPE W UNIT I � � 513 � _ _ � 511 DN UP-- o ° <br />Uj <br />3 1' - 1/2" 7P` 3 7C I► SHEET A110 I II SHEET A130 I I I co / w <br />482 1 FT11 <br />22. AT DOORS INTO ELECTRICAL CONTROL > <br />- - - - - ♦- - - - - - ci ® II ISTAIR #1 1 7A / PANEL ROOMS, SIGNAGE SHALL BE Q I- <br />I - - 11U / PROVIDED ON THE DOOR STATING � 0 <br />U4 11ii I DAS SHAFT I ST-1 I / 1 'ELECTRICAL ROOM' z <br />7A UP N II O, 23. AT DOORS INTO FIRE PROTECTION 0 o <br />_ UTILITY 0 ° ° II 0 / Q <br />STORAGE 9 503 19 `� 504 ° of 18 I / EQUIPMENT ROOMS CONTAINING Q o m <br />o - 10 4 SPRINKLER RISERS, FACP, OR OTHER c = o <br />DN iSTAI #3 I S- 05 00 1 STOR GE SUPPRESION CONTROL ELEMENTS, N aa)i ° ~ z <br />ST-3 10' - 0" 1 4 1 / Q 1 � -1 / Q o = <br />73:Q <br />I i REF. �J L - REF. S-503 CORRIDOR S/�AFT APPROVED SIGNAGE SHALL BE L L o <br />B 5 �1 I 1 1 - - ri!- 0 L O 2 --- - '/ B 5 I PROVIDED AND READILY VISIBLE PER w N o <br />CO�RRID R F.E.C. 2LU <br />7 7K F.E.C. / IFC SECTION 509.1 = N <br />Ka - 500- - 7C - - - - - - - - - - - - - - 7 �- - - - - - - - - - I 24. TWO-WAY COMMUNICATION L � w Q U CO o a-< <br />co `n SYSTEM PER IBC SECTION 1009.8 0 U J - w� <br />I 7K F.E.C. STORAGI= ♦ ♦ co _ J vo rn �Uj <br />0 O - ST GE a � � � zw <br />] I L II �r [ - 3 1/4" II R� EF.� �r DO II �r -i / L a E w <= <br />Z I 1 RIC <br />II 0 S-502 Q wzQco <br />° ° ° ° ° p H rn °� w o <br />° ° o ° ° II o LLco O U_ M <br />o I II <br />ZL 1 D W <br />UI C <br />o <br />0 7A II - I 1 1 <br />II UNIT 4.2 1 UNIT .1 - UNIT 1.1 - UNIT 1.1 UNIT 3.1 - - - - M l <br />p 516 51 514 512 510 <br />ILL <br />I SHEET A140 SHEET A110 SHEET Al 10 SHEET A110 SHEET A130 - - <br />N 11 I eo"7' <br />I 7D 7D <br />� N <br />E 1 II <br />� II <br />O II <br />- <br />x 1 <br />go 7A <br />L I I <br />� N <br />U) - <br />1' 10'-6' 8'-9" 3'-9" <br />UI 19'-3" 01 <br />B. B.b <br />1 <br />A423 <br />Q <br />z <br />w <br />J <br />12'-10" 2'-71/ <br />29' - 1 /2" 1 " 1 <br />B.c B.d B.e <br />2 <br />A420 A421 <br />V 7A V <br />25'-11" 1'- 8'-101/2" <br />1 <br />B.f01 <br />CBg <br />A320 <br />/ <br />0 <br />/ - <br />c <br />CD <br />/ 7A <br />10'-0" 3 -21/ " / <br />17' - 0 1/2" 1" 25' - 11" 1" / 46' - 1" <br />/ <br />BLDG B - LEVEL 5 SOUTH <br />1/8" = 1'-01, <br />B.h <br />KEY PLAN <br />BUILDING B <br />PROJECT #: 1827 <br />DRAWN BY: AT <br />CHECKED BY: ST <br />BLDG B - FLOOR 5 <br />SOUTH <br />