Laserfiche WebLink
Q CEILING PLAN LEGEND & NOTES <br />co <br />I, <br />00 1 CENTER GRID IN ROOM OR <br />�r <br />N CORRIDOR, U.N.O. <br />N JOHNBRAUNDINc. <br />2. GWB CEILING TO BE ATTACHED �52nd Ave. South <br />SON <br />o TO UNDERSIDE OF FLOOR Suite 300 <br />FRAMING, U.N.O. Seattle, WA 98188 <br />3. SEE MECHANICAL SHEETS FOR Phone 206.766.8300 <br />LOCATION OF DUCTS, FIRE www.johnsonbraund.com <br />DAMPERS AND COMBINATION ARCH ITECTU RE <br />FIRE/SMOKE DAMPERS <br />I I INTERIOR DESIGN <br />4. SEE ELECTRICAL DRAWINGS <br />FOR LOCATION OF EXIT SIGNS, Greg L. Wwi <br />INCLUDING LOW-LEVEL EXIT Jeffrey A.. Williams,a <br />I SIGNS, AND SMOKE DETECTORS <br />u I�5. CENTER SPRINKLER HEADS ON <br />A322 1 I I 1 A323 CEILING TILES <br />6. SEE SHEETS A040 AND A041 <br />FOR ASSEMBLY TYPES <br />7. NFPA 13 FIRE SPRINKLER SYSTEM TO BE <br />DESIGN -BUILD <br />8. NFPA 72 FIRE ALARM SYSTEM TO BE <br />DESIGN BUILD <br />M <br />B,2 9. PROJECTIONS INTO THE ACCESSIBLE <br />PATH OF TRAVEL BY WALL SCONCES 8556 <br />GWB AND OTHER SUCH DEVICES BETWEEN REGISTERED <br />THE HEIGHT OF 27" AFF AND 80" AFF ARE ARCHITECT <br />LIMITED TO 4" IN DEPTH. <br />I <br />eFFREY THUR WILLIAM <br />WASHINGTON <br />Room name CEILING TAG STAMP <br />I101 <br />7,-I8„ <br />GYPSUM WALL BOARD <br />GB o CEILINGco <br />I 0 0.. <br />OIL CEILING HEIGHT MARKER <br />01 RETURN REGISTER <br />aI SUPPLY DIFFUSER <br />I IFIN. CEILING TO BE UNDERSIDE OF FLOOR/CEILING � CLG. MOUNTED EXIT SIGN <br />OR ROOF/CEILING ASSEMBLY U.N.O. m W/ DIRECTIONAL ARROW <br />I <br />M,4�( WALL MOUNTED EXIT SIGN <br />I � o <br />GIB WALL/CEILING EXIT SIGN BASIS OF DESIGN: <br />NAVILITE NXPB-3-G-WH 90 MIN. BATTERY <br />BACK-UP. GREEN LETTERING <br />------------- <br />I <br />7' - 8" <br />G B <br />A 20 <br />0 0 <br />w <br />I <br />a <br />LU <br />0 <br />I 0 <br />o � r <br />MAXo <br />w <br />U) <br />G B o <br />w <br />0 <br />w <br />w <br />IUE' z <br />o <br />z <br />7'- 8" -�w <br />vQ <br />w <br />G B <br />Q� <br />Ez <br />I �z <br />Z <br />Off <br />_ 7 <br />M w m <br />O <br />� F_ O <br />M L a�Q o= <br />w0 <br />j N �� <br />Q <br />G B O LM > t' LU <br />LU <br />_ w� <br />00 <br />co J J (n O In LU <br />Q N 00 w <br />w a (n=Q z> <br />L 0 E w <z <br />Z I I I *GB <br />w z U o ai LU wQLu <br />LL cn O� m a <br />�I I M o <br />GB <br />U <br />L <br />U_ I <br />KEY PLAN <br />N <br />e0 I I <br />A322 2 <br />� I 17 8 � <br />E GU�IB <br />O PROJECT #: 1827 <br />B.b B.d I B.e B.g <br />X I DRAWN BY: AT <br />g CHECKED BY: ST <br />i I <br />BLDG B - RESIDENTIAL <br />U I FLOOR MID - RCP <br />I <br />w <br />BUILDING B <br />Q I�n A228B <br />�� BLDG B - RESIDENTIAL FLOOR MID - RCP PERMIT SET 10/09/2020 <br />/k <br />w <br />1/8" = 1'-0" <br />Q <br />z <br />� <br />o <br />m <br />w <br />w <br />H <br />w <br />0 <br />0 <br />wQo <br />�o� <br />c <br />N <br />d <br />0 <br />d <br />ca <br />0 <br />d <br />