My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
8102 EVERGREEN WAY EVERETT 4 CORNERS - BLDG B 2025-08-22
>
Address Records
>
EVERGREEN WAY
>
8102
>
EVERETT 4 CORNERS - BLDG B
>
8102 EVERGREEN WAY EVERETT 4 CORNERS - BLDG B 2025-08-22
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2025 11:16:45 AM
Creation date
7/29/2025 6:29:44 AM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
8102
Tenant Name
EVERETT 4 CORNERS - BLDG B
Imported From Microfiche
No
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
1616
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Q <br />rn <br />1p <br />00 <br />0 <br />N <br />O <br />N <br />N <br />L: <br />X <br />a) <br />co <br />I <br />Z <br />I <br />C) <br />UI <br />L <br />E <br />O <br />U <br />O <br />LL <br />ti <br />N <br />e0 <br />E <br />U <br />O <br />0 <br />X <br />a) <br />g <br />L <br />U) <br />A <br />uj <br />Q <br />z <br />w <br />J_ <br />LL <br />(4) 3/8" X 3 1/2" LAG SCREWS <br />COUNTERTOP AND <br />BACKSPLASH <br />REMOVABLE 1/2" x 3-5/8" <br />FACE TRIM- MATCH <br />CABINETS <br />17" <br />3/4" x 3" SUPPORT CLEAT <br />1 <br />/ <br />3/4" x 3" SUPPORT CLEAT <br />- MOUNT BETWEEN VANITY <br />3/4" PLYWOOD <br />BRACE AND WALL OR ANOTHER <br />FINISHED TO <br />I <br />VANITY CABINET <br />O <br />MATCH CABINET <br />i i ��� <br />a Q <br />~ <br />AND EDGE <br />I l I/ <br />�O � <br />a) <br />W <br />BANDED. <br />w ��,,,� <br />_ <br />W INSULATE HOT z <br />N <br />z <br />Q <br />1_WATER AND DRAIN <br />g <br />� <br />`� <br />Z) LINES _ <br />ti <br />z <br />O <br />(, N <br />N <br />Y 3 1/4" <br />REMOVABLE CABINET <br />REMOVABLE CABINET <br />L � <br />TYPE I COUNTER BRACE <br />co <br />SEE DETAILS 15-16 THIS SHEET FOR <br />REMOVED CABINET CONDITION <br />16 ACCESSIBLE COUNTER BRACE - SECTION <br />//"12 REMOVABLE CABINET <br />TYPE I COUNTER TYPE II COUNTER BRACE 15" <br />BRACE (SIDE (SIDE ELEVATION) <br />ELEVATION) SEE TYPE II COUNTER BRACE MIN. <br />DETAILS THIS SHEET. CAN BE OF ANY 11 TOP O SINK RIM <br />CONFIGURATION. <br />TYPE I COUNTER BRACE WHERE LAVATORY ENCROACHES KNEE z M <br />REQ'D CLEAR FLOOR SPACE @ WATERCLOSET, BATHTUB OR SPACE N <br />TURNING CIRCLE. TYPE II COUNTER BRACE @ ALL OTHER <br />LOCATIONS UNLESS INDICATED. 30" <br />MIN. <br />FINISHED TO MATCH <br />- <br />2X4 -FULL <br />1. <br />WATER TEMPERATURE SHALL NOT EXCEED 120° F. <br />CABINETS <br />HT.TYP. <br />2. <br />HOT WATER & DRAIN PIPING TO BE INSULATED OR <br />OTHERWISE CONFIGURED TO AVOID CONTACT. <br />- <br />3. <br />MAXIMUM SINK BOWL DEPTH SHALL BE 6-1/2". <br />_ <br />4. <br />SELF -CLOSING FAUCET VALVES SHALL REMAIN OPEN <br />— <br />— <br />— — <br />— — <br />— <br />—� <br />FOR AT LEAST 10 SECONDS PER OPERATION. <br />30"X48" CLR. <br />- <br />5. <br />CABINETS MAY BE INSTALLED UNDER <br />FLR. SPACE <br />LAVATORIES/SINKS WITHIN DWELLING UNITS IF THE <br />L <br />_ <br />`V <br />CABINETRY IS EASILY REMOVABLE AND FLOORING <br />8" MIN. <br />EXTENDS UNDER. (TYPE A UNITS, TYPICAL. TYPE B <br />CENTERLINE <br />UNITS ONLY AS NOTED) <br />KNEE &TOE <br />OF SOLID <br />6. <br />SEE ALSO ACCESSIBILITY NOTES ON SHEET A550. <br />SPACE <br />BLKG. <br />CLEARANCE <br />z_ <br />DIMENSTIONS <br />N <br />- <br />Z <br />15 ACCESSIBLE COUNTER BRACE - PLAN <br />11 ACCESSIBLE COUNTER & SINK <br />11" MIN. 6" MAX. <br />3" = 1'-0" <br />1/4" = 1'-0" <br />* DIMENSION IS 46" MAX. A.F.F. AND LOCATED 36" MIN. FROM <br />INSIDE CORNERS IN KITCHENS (SIDE REACH OVER COUNTERTOP), <br />TYPICAL <br />114 RFC FPTOC:I F Mni INTINr, 14FIr,14T-q <br />1 1/2" = 1'-0" <br />1. GRAB BARS SHALL HAVE AN OUTSIDE DIAMETER OF NOT LESS THAN <br />1-1/4" OR MORE THAN 1-1/2" AND SHALL PROVIDE A CLEARANCE OF <br />1-1/2" BETWEEN THE GRAB BAR AND THE WALL. <br />2. TOP OF GRAB BARS SHALL BE LOCATED NOT LESS THAN 33" AND NOT <br />MORE THAN 36" ABOVE THE FLOOR OF THE ADJACENT CLEAR SPACE. <br />3. THE STRUCTURAL STRENGTH OF GRAB BARS, TUB AND SHOWER <br />SEATS, FASTENERS AND MOUNTING DEVICES SHALL MEET THE <br />FOLLOWING REQUIREMENTS. <br />A. BENDING STRESS INDUCED IN A GRAB BAR OR SEAT <br />INDUCED BY THE MAXIMUM BENDING MOMENT FROM THE <br />APPLICATION OF 300 POUNDS SHALL BE LESS THAN THE <br />ALLOWABLE STRESS FOR THE MATERIAL OF THE GRAB <br />BAR OR SEAT. <br />B. SHEAR STRESS INDUCED IN A G.B. OR SEAT BY THE <br />APPLICATION OF 300 POUNDS SHALL BE LESS THAN THE <br />ALLOWABLE SHEAR STRESS FOR THE MATERIAL OF THE <br />G.B. OR SEAT. IF THE CONNECTION BETWEEN THE G.B. OR <br />SEAT AND ITS MOUNTING BRACKET OF OTHER SUPPORT <br />IS CONSIDERED TO BE FULLY RESTRAINED, THEN THE <br />DIRECT AND TORSIONAL SHEAR STRESSES SHALL BE <br />TOTALED FOR THE COMBINED SHEAR STRESS, WHICH <br />SHALL NOT EXCEED THE ALLOWABLE SHEAR STRESS. <br />C. SHEAR FORCE INDUCED IN A FASTENER OR MOUNTING <br />DEVICE FROM THE APPLICATION OF 300 POUNDS SHALL <br />BE LESS THAN THE ALLOWABLE LATERAL LOAD OF EITHER <br />THE FASTENER OR MOUNTING DEVICE OR THE <br />SUPPORTING STRUCTURE, WHICHEVER IS THE SMALLER <br />ALLOWABLE LOAD. <br />D. TENSILE FORCE INDUCED IN A FASTENER BY A DIRECT <br />TENSION FORCE OF 300 POUNDS PLUS THE MAXIMUM <br />MOMENT FROM THE APPLICATION OF 300 POUNDS SHALL <br />BE LESS THAN THE ALLOWABLE WITHDRAWAL LOAD <br />BETWEEN THE FASTENER AND THE SUPPORTING <br />STRUCTURE. <br />13 GRAB BAR REQUIREMENTS <br />1/4" = 1'-0" <br />EXTENT OF NON - <br />ABSORBENT <br />MATERIAL <br />TOP OF TOP OF <br />GRAB z GRAB 12" 24" <br />BAIR z z B R _ <br />o C2 <br />w <br />C?> C?co m co <br />4" MAX. MIDPOINT OF TUB <br />NJ <br />24" 15 3/4" ;Ojz <br />co <br />co <br />CONTROL <br />AREA <br />TYPE A <br />U M Q M UNITS <br />18„ SEE NOTE #4 <br />O <br />NOTES <br />24" <br />wil <br />1. TOILET CAN ENCROACH THE REQUIRED CLEAR FLOOR r---r <br />_ X <br />CN <br />SPACE @ TUB IN TYPE B UNITS. <br />g <br />2. AT TYPE A UNITS: A HAND SHOWER WITH A HOSE 59" <br />4" MAX. <br />MIN. LENGTH THAT CAN BE USED BOTH AS A FIXED <br />�t <br />SHOWER HEAD AND AS A HAND SHOWER SHALL BE <br />PROVIDED. THE HAND SHOWER SHALL HAVE A <br />*CLEAR <br />CONTROL WITH A NONPOSITIVE SHUT-OFF FEATURE. i <br />i _ X <br />AN ADJUSTABLE HEIGHT SHOWER HEAD MOUNTED ON A 1 <br />FLOOR N Q <br />VERTICAL BAR SHALL BE INSTALLED SO AS NOT TO �___LSPACE <br />OBSTRUCT THE USE OF GRAB BARS. <br />3. CONTROL AREA RESTRICTION FOR TYPE A UNITS ONLY. <br />4. AT TYPE B UNITS WHERE WATER CLOSET IS DIRECTLY <br />ADJACENT TO BATHTUB, PROVIDE BLOCKING FOR A 24" <br />12" MIN. <br />REAR GRAB BAR AND A FLIP DOWN GRAB BAR AS <br />* 30"X60" TYPE A <br />SHOWN. <br />48"X60" TYPE B <br />- -iiqiii - <br />-11l <br />■ - <br />co <br />co <br />co <br />1 <br />E <br />3 <br />4 <br />TOP OF GRAB <br />BAR <br />LIGHT GAUGE FRAMED SOFFIT - <br />BELOW 1-HR FLR/CEILING <br />ASSEMBLY (ONLY AS INDICATED ON <br />UNIT PLANS) <br />PROVIDE BLOCKING AT ALL <br />CABINET MODULES 36" WIDE OR <br />LESS. <br />PRE -MANUFACTURED UPPER <br />CABINET UNITS - SEE INTERIOR <br />ELEVATIONS. <br />PRE -FORMED PLASTIC LAMINATE <br />COUNTERTOP & TILE BACKSPLASH <br />OR APPROVED. <br />PROVIDE BLOCKING AT ALL <br />CABINET MODULES 36" WIDE OR <br />LESS. <br />2" MIN. FILLER AT INSIDE BLIND <br />CORNER CABINETS - SEE INT.ELEV <br />PRE -MANUFACTURED BASE <br />CABINET UNITS - SEE INT. ELEV. <br />FACE OF FINISHED WALL <br />1/2" <br />VERTICAL <br />GRAB BAR <br />NOT REQ'D AT <br />DWELLING <br />39"-41" UNITS <br />NOTE 3 <br />42" 12„ NOTE 4 NOTE 2 <br />00 z NOTE 1 <br />TOP OF G.B. <br />C?C?II <br />M M _ 00 coII N U <br />co N co <br />co <br />*15"-17" IN DWELLING UNITS TOP OF SEAT 36" MIN. NOTE 3 <br />NOTES: Jp 12" 24" <br />VANITY CAN OVERLAP REQ'D CLR. IN. MIN. 18" @ TYPE A UNIT <br />FLR. SPACE @ DWELLING UNITS 15" @ TYPE B UNIT <br />ONLY. KNEESPACE (OR REMOVABLE <br />CAB) REQ'D @ TYPE A UNITS. TYPE A <br />UNITS W/OVERLAP REQUIRES <br />60"X66" CLR. FLR. SPACE. z L = (- <br />FLUSH CONTROL SHALL BE 42„ NOTE 1 <br />MOUNTED FOR USE FROM THE OPEN <br />SIDE OF THE WATERCLOSET AREA. MIN. 60"X56" CLR. FLR. SPACE <br />(TYPE A UNIT) 16" MIN. - 18"I MAX (48"X56" TYPE B UNIT) <br />REAR GRAB BAR CAN BE 24" IN — — — — — ___1 <br />DWELLING UNITS WHERE WALL __J 60"X66" CLR. FLR. SPACE <br />SPACE DOES NOT ALLOW FOR 36". @ TYPE A UNITS <br />IN TYPE B UNITS, WHERE FIXTURES 60" W/VANITY OVERLAP <br />ARE LOCATED ON EACH SIDE A <br />SWING -UP GRAB BAR IS PERMITTED <br />ON THE 18" SIDE. <br />�5 ACCESSIBLE WATER CLOSET <br />1/4" = 1'-0" <br />FRAMED SOFFIT - BELOW 1-HR <br />FLR/CEILING ASSEMBLY (ONLY AS <br />INDICATED ON UNIT PLANS) <br />PROVIDE WOOD TRIM IF GAP <br />> 3/8" <br />CLEAT AS REQ <br />PROVIDE BLOCKING AT ALL <br />CABINET MODULES 36" WIDE OR <br />LESS. <br />PRE -MANUFACTURED UPPER <br />CABINET UNITS - SEE INTERIOR <br />ELEVATIONS. <br />LIGHT GAUGE FRAMED SOFFIT - <br />BELOW 1-HR FLR/CEILING <br />ASSEMBLY (ONLY AS INDICATED ON <br />UNIT PLANS) <br />PROVIDE BLOCKING AT ALL <br />CABINET MODULES 36" WIDE OR <br />LESS. <br />PRE -MANUFACTURED UPPER <br />CABINET UNITS - SEE INTERIOR <br />ELEVATIONS. <br />PRE -FORMED PLASTIC LAMINATE <br />COUNTERTOP & TILE BACKSPLASH <br />OR APPROVED. <br />PROVIDE BLOCKING AT ALL <br />CABINET MODULES 36" WIDE OR <br />LESS. <br />2" MIN. FILLER AT INSIDE BLIND <br />CORNER CABINETS - SEE INT.ELEV <br />PRE -MANUFACTURED BASE <br />CABINET UNITS - SEE INT. ELEV. <br />FACE OF FINISHED WALL <br />EXTERIOR INTERIOR <br />DOOR FRAME & <br />DOOR AS <br />SCHEDULED <br />LOW PROFILE MTL. <br />THRESHOLD & COMP. <br />WEATHER STRIP W. <br />SEALANT <br />F.F. F.F. <br />DOORS TO ACCESSIBLE SPACES SHALL HAVE A <br />DOOR THRESHOLD WITH A MAXIMUM HEIGHT OF <br />1/2" PER PER ICC/ANSI 117.1 SEC. 404.2.4. <br />CHANGES IN LEVEL GREATER THAN 1/4" IN HEIGHT <br />AND NOT MORE THAN 1/2" MAX. IN HEIGHT SHALL BE <br />BEVELED WITH A SLOPE NOT STEEPER THAN 1:2 <br />PER ICC/ANSI A117.1 SEC. 303.3 <br />a1111• • ■ ■ • <br />\I <br />OHNSON BRAUNDINC. <br />15200 52nd Ave. South <br />Suite 300 <br />Seattle, WA 98188 <br />Phone 206.766.8300 <br />www.johnsonbraund.com <br />ARCHITECTURE <br />INTERIOR DESIGN <br />Greg L. Allwine, <br />Jeffrey A. Williams, <br />8556 <br />REGISTERED <br />ARCHITECT <br />J �ARTHUR <br />STAMP <br />Q <br />r <br />0m <br />FD <br />a- <br />� <br />Cie <br />LULU <br />w <br />o <br />w <br />a <br />H <br />w <br />0 <br />Q <br />wQo <br />CO <br />o <br />c <br />EL <br />N <br />0 <br />0 <br />d <br />a <br />0 <br />d <br />Uj <br />w <br />0 <br />a <br />Uj <br />w <br />0 <br />r <br />z <br />Q <br />z <br />0 <br />w <br />U) <br />D <br />0 <br />w <br />Uj <br />w <br />0 <br />z <br />w <br />z <br />o <br />z <br />�w <br />Q <br />Ew <br />Q= <br />Q� <br />,o <br />�z <br />C� <br />z <br />M <br />o <br />oQ <br />w< <br />m <br />N <br />rn <br />Fo <br />L <br />tm <br />o = <br />w0 <br />A+ <br />W <br />> <br />w a� <br />o <br />� o <br />L <br />w <br />Q <br />0 <br />.. <br />z <br />< 0 <br />a- <br />Q <br />� � <br />UF <br />co <br />J J CO(n 00 <br />� w <br />w <br />a n :5 <br />z> <br />L <br />o <br />Q Ewe <br />az <br />Q <br />W C) <br />o C) <br />w <br />z L C) N <br />�Uj <br />- <br />11 <br />cn <br />O li pp <br />a_ <br />PROJECT #: 1827 <br />DRAWN BY: GLEE <br />CHECKED BY: ST <br />INTERIOR & <br />ACCESSIBILITY <br />DETAILS <br />A550 <br />PERMIT SET 10/09/2020 <br />
The URL can be used to link to this page
Your browser does not support the video tag.