Laserfiche WebLink
• <br /> Min Vel Max Vel Min Slope Max Slope Min Cover <br /> 2.00 ft/s 15.00 ft/s 0.50% 2.00% ( 3.00 ft <br /> Drop across MH 0.00 ft Ex/Infil Rate 0.00 in/hr <br /> Record Id: P-6 <br /> Section Shape: Circular <br /> Uniform Flow Method: j Manning's Coefficient: 0.009 <br /> Routing Method: Travel Time Shift Contributing Hyd <br /> DnNode Vault A UpNode CB-6 <br /> Material unspecified (Size 12 in Diam <br /> Ent Losses Groove End w/Headwall <br /> Length 60.00 ft Slope 6.00% <br /> Up Invert 441.09 ft Dn Invert 437.49 ft <br /> Conduit Constraints <br /> Min Vel Max Vel Min Slope Max Slope Min Cover <br /> 2.00 ft/s 15.00 ft/s 0.50% j 2.00% 3.00 ft <br /> Drop across MH I 0.00 ft Ex/Infil Rate 0.00 in/hr <br /> Record Id: P-7 <br /> Section Shape: Circular <br /> Uniform Flow Method: Manning's Coefficient: 0.009 <br /> Routing Method: Travel Time Shift Contributing Hyd <br /> DnNode CB-6 UpNode CB-7 <br /> Material I unspecified Size 12 in Diam <br /> Ent Losses Groove End w/Headwall <br /> Length 76.00 ft Slope 2.20% <br /> Up Invert 442.77 ft 1Dn Invert 441.098 ft <br /> Conduit Constraints <br /> Min Vel Max Vel Min Slope Max Slope Min Cover <br /> I 2.00 ft/s 15.00 ft/s 0.50% 2.00% 3.00 ft <br /> Drop across MH 0.00 ft Ex/Infil Rate I 0.00 in/hr <br /> July 2014 5-18 LDC Job No. 13-144 <br />