Laserfiche WebLink
1 <br /> 1 <br /> I <br /> 5 year 0.057209 <br /> 10 year 0.067734 <br /> 25 year 0.08173 <br /> 50 year 0.092672 <br /> I <br /> 100 year 0.104064 <br /> Total Volume Filtrated (acre-ft)= 16.473 <br /> Percent Filtered (%) = 93.98 <br /> 1 <br /> POC #2 <br /> I <br /> Facility FAILED duration standard for 1+ flows. <br /> Flow(CFS) Predev Dev Percentage Pass/Fail <br /> 0.0218 659 639 96 Pass <br /> II 0.0225 595 581 97 Pass <br /> 0.0232 538 500 92 Pass <br /> 0.0239 497 446 89 Pass <br /> I <br /> 0.0247 452 410 90 Pass <br /> 0.0254 413 364 88 Pass <br /> 0.0261 366 328 89 Pass <br /> 0.0269 312 301 96 Pass <br /> I <br /> 0.0276 290 269 92 Pass <br /> 0.0283 267 246 92 Pass <br /> 0.0291 246 223 90 Pass <br /> 0.0298 224 200 89 Pass <br /> 1 0.0305 195 174 89 Pass <br /> 0.0312 178 158 88 Pass <br /> 0.0320 151 142 94 Pass <br /> 0.0327 133 120 90 Pass <br /> I <br /> 0.0334 120 102 85 Pass <br /> 0.0342 109 97 88 Pass <br /> 0.0349 101 90 89 Pass <br /> 0.0356 88 81 92 Pass <br /> I 0.0363 76 76 100 Pass <br /> 0.0371 70 70 100 Pass <br /> 0.0378 65 62 95 Pass <br /> I <br /> 0.0385 62 58 93 Pass <br /> 0.0393 59 53 89 Pass <br /> 0.0400 56 51 91 Pass <br /> 0.0407 52 47 90 Pass <br /> I <br /> 0.0414 49 43 87 Pass <br /> 0.0422 46 42 91 Pass <br /> 0.0429 42 38 90 Pass <br /> 0.0436 39 33 84 Pass <br /> 1 0.0444 35 32 91 Pass <br /> 0.0451 34 30 88 Pass <br /> 0.0458 34 30 88 Pass <br /> 0.0466 32 29 90 Pass <br /> I <br /> 0.0473 31 28 90 Pass <br /> 0.0480 28 25 89 Pass <br /> 0.0487 26 25 96 Pass <br /> 0.0495 25 24 96 Pass <br /> I <br /> 0.0502 24 23 95 Pass <br /> 0.0509 24 23 95 Pass <br /> 0.0517 23 21 91 Pass <br /> I <br /> I <br />