Preliminary Stormwater Site Plan Everett, WA <br /> I <br /> Maintenance Checklist for Fencing/Shrubbery Screen/Other Landscaping <br /> I <br /> Frequency Drainage 4 Problem Conditions To Check For Conditions That Should Exist <br /> System <br /> Feature <br /> M General Missing or broken Any defect in the fence or screen Fence is mended or shrubs <br /> I parts/dead shrubbery that permits easy entry to a facility replaced to form a solid barrier to <br /> entry. <br /> M,S Erosion Erosion has resulted in an opening Replace soil under fence so that <br /> under a fence that allows entry by no opening exceeds 4 inches in <br /> ' M Unruly vegetation people or pets. height. <br /> Shrubbery is growing out of control Shrubbery is trimmed and weeded <br /> or is infested with weeds. to provide appealing aesthetics. <br /> Do not use chemicals to control <br /> I <br /> weeds. <br /> A Wire Damaged parts Posts out of plumb more than 6 Posts plumb to within 1-1/2 <br /> Fences inches. inches of plumb. <br /> A Top rails bent more than 6 inches. Top rail free of bends greater than <br /> 1 inch. <br /> i A Any part of fence(including posts, is gned and meets design <br /> top rails,and fabric)more than 1 foot standards. <br /> Fenceali <br /> out of design alignment. <br /> A Missing or loose tension wire. Tension wire in place and holding <br /> I fabric. <br /> A Missing or loose barbed wire that is Barbed wire in place with less <br /> sagging more than 2-1/2 inches than 3/4-inch sag between posts. <br /> between posts. <br /> A Extension arm missing,broken,or Extension arm in place with no <br /> bent out of shape more than 1-1/2 bends larger than 3A inch. <br /> inches. <br /> A Deteriorated paint or Part or parts that have a rusting or Structurally adequate posts or <br /> I <br /> protective coating scaling condition that has affected parts with a uniform protective <br /> structural adequacy. coating. <br /> M Openings in fabric Openings in fabric are such that an No openings in fabric. <br /> 8-inch diameter ball could fit <br /> through. <br /> I <br /> Maintenance Checklist for Conveyance Systems (Pipes, Ditches and Swales) <br /> I <br /> Frequency Drainage ,J Problem Conditions To Check For Conditions That Should Exist <br /> System <br /> Feature <br /> M,S Pipes Sediment& Accumulated sediment that exceeds Pipe cleaned of all sediment and <br /> I <br /> debris 20%of the diameter of the pipe. debris. <br /> M Vegetation Vegetation that reduces free movement All vegetation removed so water <br /> of water through pipes. flows freely through pipes. <br /> 1 A Damaged Protective coating is damaged;rust is Pipe repaired or replaced. <br /> (rusted,bent, causing more than 50%deterioration to <br /> or crushed) any part of pipe. <br /> M Any dent that significantly impedes Pipe repaired or replaced. <br /> I flow(i.e.,decreases the cross section <br /> area of pipe by more than 20%). <br /> M Pipe has major cracks or tears allowing Pipe repaired or replaced. <br /> groundwater leakage. <br /> If you are unsure whether a problem exists, please contact a Professional Engineer. <br /> Comments: <br /> I A = Annual (March or April, preferred) <br /> M = Monthly(see schedule) <br /> S = After major storms (use 1-inch in 24 hours as a guideline) <br /> I <br /> I <br /> PACLAND Job# 50175001 Page 19 <br />