My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3810 RIVERFRONT BLVD BLDG B 2025-10-27
>
Address Records
>
RIVERFRONT BLVD
>
3810
>
BLDG B
>
3810 RIVERFRONT BLVD BLDG B 2025-10-27
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/27/2025 10:21:17 AM
Creation date
7/31/2025 10:20:58 AM
Metadata
Fields
Template:
Address Document
Street Name
RIVERFRONT BLVD
Street Number
3810
Tenant Name
BLDG B
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
544
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Page 1 of 3 <br />djKmzan&Associates, I nc. <br />Geotechnical Engineering . Environmental Engineering <br />Construction Testing and Inspection <br />Field <br />Report NO.: 0962117111232021CG <br />DATE: 11/23/2021 Set Count: CONTRACTOR: Shelter Holdings <br />PROJECT #: 09621171 PERMIT #: B 1912-032 <br />PROJECT: River&ont Building B INSPECTOR: Charles Green <br />LOCATION: 3810 Riverfront Boulevard JURISDICTION: City of Everett <br />KA P.M.: Jeff Mercer WEATHER: Overcast/Rain TEMP: 42' F <br />Report #74 <br />Inspector arrived on site at Contractor's (Shelter Holdings) request <br />to perform a visual inspection of reinforcing steel for cast -in -place <br />walls prior to the placement of concrete. On arrival, Inspector met <br />with contractor representative to determine the scope of work for the <br />day and to review the on -site permit plan set. <br />Inspector noted the formwork was commercial reusable formwork, and the <br />dimensions conformed with approved plans, and wall form sections <br />already installed were sufficiently braced to resist concrete <br />placement pressures and to maintain dimensionality during the <br />placement and internal vibratory consolidation of concrete. <br />Reinforcing steel was the correct size and type per plans, and was <br />spliced in conformance with the reinforcing steel splice tables in the <br />permit plan notes. No exceptions were noted, and contractor will have <br />areas that were still in progress during the inspection inspected <br />prior to the closing up of forms in preparation for the placement of <br />concrete. <br />Wall Resteel in progress <br />Offices Serving the Western United States <br />Lynnwood (425) 485-5519 • Poulsbo (360) 598-2126 • Tacoma (253) 939-2500 <br />The information provided on this report is prepared for the exclusive use of the client, This report may not be reproduced in any format without the written permission of the client and Krazan & Associates. This report <br />indicates our inspectors observation and testing results based on site conditions and contractor activities. This information is subject to review prior to final submittal. By signing this report, our inspector does not accept <br />responsibility for validity of results. The same information has been provided by others on site. The test results apply only to the specific locations, and items inspected or tested <br />
The URL can be used to link to this page
Your browser does not support the video tag.