Page 1 of 1 <br />d1qrJKrazan&Associates,Inc. <br />Geotechnical Engineering . Environmental Engineering <br />Construction Testing and Inspection <br />Field <br />Report NO.: 09621171DFR5202022JD-0 <br />DATE: 5/20/2022 Set Count: 0 CONTRACTOR: Shelter Holdings / Day Spring Construction <br />PROJECT #: 09621171 PERMIT #: B 1912-032 <br />PROJECT: Riverfront, Building B INSPECTOR: Jeff Dewey <br />LOCATION: 3810 Riverfront Blvd. JURISDICTION: City of Everett <br />KA P.M.: Jeff Mercer WEATHER: Partly Sunny TEMP: 50' F <br />- A representative of Krazan and Associates arrived on -site as scheduled to perform construction observation <br />and/or materials testing. While on -site we observed the following operations: <br />Drill and EV xv: <br />- Day Spring Construction performed drill and epoxy operations for placement of 1" all thread for (2) hold downs <br />on level 2, Elevator 1 North at approximately gridline location E.5/20.0. Holes were drilled to a minimum depth of <br />20" utilizing a 1 %" bit and roto-hammer. A wire brush and compressed air were then used to clean the holes prior <br />to epoxy placement. Day Spring Construction applied Simpson 3G epoxy (with an expiration date of 04/13/2023) <br />to fill the previously drilled holes. 1" x 30" all thread was inserted with a twisting motion until bottomed out in the <br />holes. Epoxy was observed to be coming from the holes during and after anchor insertion. The anchors were <br />installed in general compliance with the project plans, specifications, governing standards and engineer direction. <br />• Documents Referenced: S3.11B, RFI-237 <br />- JP (with Shelter Holdings) was notified of all observations prior to Krazan's departure from the project site. <br />Reviewed <br />To the best of"my knowl <br />regulatory requirements. <br />ASTM Test #: <br />Asset <br />the above WAS performed in accordance with the approved plans, specifications and <br />Technician: <br />Jeff Dewey <br />Offices Serving the Western United States <br />Lynnwood (425) 485-5519 • Poulsbo (360) 598-2126 • Tacoma (253) 939-2500 <br />The information provided on this report is prepared for the exclusive use of the client. This report may not be reproduced in any format without the written permission of the client and Krazan & Associates. This report <br />indicates our inspectors observation and testing results based on site conditions and contractor activities. This information is subject to review prior to final submittal. By signing this report, our inspector does not accept <br />responsibility for validity of results. The same information has been provided by others on site. The test results apply only to the specific locations, and items inspected or tested. <br />