Page 1 of 2 <br />,mmKraz&Associates,Inc. <br />Geotechnical Engineering . Environmental Engineering <br />Construction Testing and Inspection <br />Field <br />Report NO.: 09621305DFR662022JD-0 <br />DATE: 6/6/2022 Set Count: 0 CONTRACTOR: Shelter Holdings / R&D Masonry <br />PROJECT #: 09621171 PERMIT #: B1912-032 <br />PROJECT: Riverfront, Building B REPORT #124 INSPECTOR: Jeff Dewey <br />LOCATION: 3910 Riverfront Blvd. JURISDICTION: City of Everett <br />KA P.M.: Jeff Mercer WEATHER: Partly Cloudy TEMP: 60' F <br />- A representative of Krazan and Associates arrived on -site as scheduled to perform construction <br />observation and/or materials testing. While on -site we observed the following operations: <br />Drill and Epoxy: <br />- R&D Masonry performed drill and epoxy operations for placement of #5 reinforcing steel for various <br />Level 1 masonry verticals along 11.3 line from D.5 to K.0, K.0 line from 11.3 to 12.0, horizontals at <br />K.0/12.0 and horizontals at D.5/11.3. Holes were drilled to a minimum depth of 5" utilizing a 3/4" bit <br />and roto-hammer. A wire brush and compressed air were then used to clean the holes prior to epoxy <br />placement. R&D Masonry applied Hilti HIT -RE 500 V3 epoxy, with an expiration date of 07/2022, to fill <br />the previously drilled holes. #5 reinforcing steel was inserted with a twisting motion until bottomed out <br />in the holes. Epoxy was observed to be coming from the holes during and after reinforcing steel insertion. <br />• Documents Referenced: S2.1113 and Detail 13 on S6.01 <br />- Bill (Superintendent with Shelter Holdings) was notified of all observations prior to Krazan's departure <br />from the project site. <br />Pro iect Photos <br />Level 1, Gridline 11 <br />41' _E1111911111K <br />Offices Serving the Western United States <br />Lynnwood (425) 485-5519 • Poulsbo (360) 598-2126 • Tacoma (253) 939-2500 <br />The information provided on this report is prepared for the exclusive use of the client. This report may not be reproduced in any format without the written permission of the client and Knutan & Associates. This report <br />indicates our inspectors observation and testing results based on site conditions and contractor activities. This information is subject to review prior to final submittal. By signing this report, our inspector does not accept <br />responsibility for validity of results. The same information has been provided by others on site. The test results apply only to the specific locations, and items inspected or tested. <br />