My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3810 RIVERFRONT BLVD BLDG B 2025-10-27
>
Address Records
>
RIVERFRONT BLVD
>
3810
>
BLDG B
>
3810 RIVERFRONT BLVD BLDG B 2025-10-27
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/27/2025 10:21:17 AM
Creation date
7/31/2025 10:20:58 AM
Metadata
Fields
Template:
Address Document
Street Name
RIVERFRONT BLVD
Street Number
3810
Tenant Name
BLDG B
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
544
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Page 1 of 1 <br />r .. <br />KmzamAssociates, Inc. <br />Geotechnical Engineering . Environmental Engineering <br />Construction Testing and Inspection <br />Field <br />Report NO.:09621171292023JLG <br />DATE: 2/9/2023 Set Count: CONTRACTOR: Shelter <br />PROJECT #: 09621171 PERMIT #: B1912-032 <br />PROJECT: Riverfront Bld B INSPECTOR: Jerry L. Gelder <br />LOCATION: 3910 Riverfront Blvd Everett JURISDICTION: City of Seattle <br />KA P.M.: WEATHER: Overcast TEMP: 500 F <br />Report #140 <br />Arrived onsite per contractors request to observe the installation of 6X6 wood post at Elevator for each <br />floor Level 2 to Roof. The post was from floor to approximately center of beam running along top of <br />elevator for the length of the front side of elevator. Though plans called for post to be installed there was <br />no detail for connecting the post to the beam. At level 2 contractor had an embed in the PT Deck that the <br />post sat in. The post was then connected to the beam with 2 A35 clips (1 each side). Level 3 to Roof <br />contractor installed 2 A35 clips at floor and beam. Items were installed per plans and specs. <br />Reviewed By: I ASTM Test #: I I Asset <br />To the best ofmy knowledge, the above WAS performed in accordance with the approved plans, specifications and <br />regulatory requirements. <br />Technician: <br />Offices Serving the Western United States <br />Lynnwood (425) 485-5519 - Poulsbo (360) 598-2126 - Tacoma (253) 939-2500 <br />The information provided on this report is prepared for the exclusive use of the client. This report may not be reproduced in any format without the written permission of the client and Ka & Associates. This report <br />indicates our inspectors observation and testing results based on site conditions and contactor activities. This information is subject to review prior to final submittal. By signing this report, our inspector does not accept <br />responsibility for validity of results. The same information has been provided by others on site. The test results apply only to the specific locations, and items inspected or tested. <br />
The URL can be used to link to this page
Your browser does not support the video tag.