My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3810 RIVERFRONT BLVD BLDG B 2025-10-27
>
Address Records
>
RIVERFRONT BLVD
>
3810
>
BLDG B
>
3810 RIVERFRONT BLVD BLDG B 2025-10-27
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/27/2025 10:21:17 AM
Creation date
7/31/2025 10:20:58 AM
Metadata
Fields
Template:
Address Document
Street Name
RIVERFRONT BLVD
Street Number
3810
Tenant Name
BLDG B
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
544
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Page 1 of 1 <br />ikiAKy an& Ass ociate s,Inc. <br />Geotechnical Engineering . Environmental Engineering <br />Construction Testing and Inspection <br />Field <br />Report NO.: 09621171DFR4102023ZZ <br />DATE: 4/10/2023 Set Count: CONTRACTOR: SHELTER HOLDTNCTS <br />PROJECT #: 09621171 PERMIT #: B1912-032 <br />PROJECT: RIVERFRONT BLDG tB" i�dvz 7_OHZINSPECTOR: Zelalem Zerihun <br />LOCATION: 3810 Riverfront Blvd, Everett, WA JURISDICTION: EVERETT <br />KA P.M.: Jeffrey S. Mercer WEATHER: Cloud TEMP: 45' F <br />A Krazan & Associates, Inc. representative revisited the above -said project as per contractor's request <br />and reinspected fireproofing intumescent paint. <br />Thin Film Intumescent Fire -Resistive Material (TFIFRM) from SHERWIN-WILLIAMS was applied <br />for two-hour rated WF steel beams (2)W10X30 at mezzanine level (level 113). As per Sherwin- <br />Williams, the dry film thickness (DFT) required was 221mils for WIOX30 located at 1 — 7/13.3 on LIB <br />and 170 mils for WIOX30 located at 2.5 — 6.5/H on L113. DFT tested using gauge named Elcometer <br />model# A456 CFTS and met or exceeded minimum required DFT and comply with 2015 IBC chapter <br />17, ASTM D7091, and AWCI (Technical 12-13). <br />Reviewed <br />To the best ofiny Liowl <br />regulatory requirements. <br />ASTM Test #: <br />Asset <br />the above WAS performed in accordance with the approved plans, specifications and <br />Technician: <br />Offices Serving the Western United States <br />Lynnwood (425) 485-5519 • Poulsbo (360) 598-2126 • Tacoma (253) 939-2500 <br />The information provided on this report is prepared for the exclusive use of the client. This report may not be reproduced in any format without the written permission of the client and Krsaan & Associates. This report <br />indicates our inspectors observation and testing results based on site conditions and contractor activities. This information is subject to review prior to final submittal. By signing this report, our inspector does not accept <br />responsibility for validity of results. The same information has been provided by others on site. <br />
The URL can be used to link to this page
Your browser does not support the video tag.