My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3810 RIVERFRONT BLVD BLDG B 2025-10-27
>
Address Records
>
RIVERFRONT BLVD
>
3810
>
BLDG B
>
3810 RIVERFRONT BLVD BLDG B 2025-10-27
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/27/2025 10:21:17 AM
Creation date
7/31/2025 10:20:58 AM
Metadata
Fields
Template:
Address Document
Street Name
RIVERFRONT BLVD
Street Number
3810
Tenant Name
BLDG B
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
544
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 <br />VERETT <br />Permit Inspections <br />City of Everett <br />5/30/2023 <br />5/30/2023 <br />ELEC 10-FINAL <br />MIKE BEARDA <br />PARTIAL <br />eTRAKiT Inspection Request <br />APPROVAL <br />Notes: <br />5/25/2023 2:50 PM EXPRESS ELECTRIC INC <br />L6 Units to gain access please contact Jed @360-410-5012 <br />Contact Name: EXPRESS ELECTRIC INC <br />Site Address: 3810 RIVERFRONT BLVD <br />Phone:3606710113 <br />e-Mail: expressadmin@expresselectric.com <br />Ok units and corridors level 6 <br />6/1/2023 <br />6/1/2023 <br />ELEC 10-FINAL <br />MICHAEL <br />CORRECTION <br />eTRAKiT Inspection Request <br />WICKLANDER <br />REQUIRED <br />Notes: <br />5/31/2023 1:55 PM EXPRESS ELECTRIC INC <br />L5 units corridor for questions please contact Jed @360-410-5012 <br />Contact Name: EXPRESS ELECTRIC INC <br />Site Address: 3810 RIVERFRONT BLVD <br />Phone:3606710113 <br />e-Mail: expressadmin@expresselectric.com <br />Corridor receptacle just outside the IDF room missing, master bath lights aren't installed in unit 527, electrical room at elevator bank, not trimmed out, <br />kitchen receptacles not trimmed out, and refrigerator circuit appears to be in operative in unit 525, several circuits dead in unit at 521. <br />6/2/2023 <br />6/2/2023 <br />ELEC 06-ROUGH IN <br />MICHAEL <br />PARTIAL <br />I <br />eTRAKiT Inspection Request <br />WICKLANDER <br />APPROVAL <br />Notes: <br />6/1/2023 2:54 PM EXPRESS ELECTRIC INC <br />Dropped ceiling L1 N. corridor for questions please contact Jed @360-410-5012 <br />Contact Name: EXPRESS ELECTRIC INC <br />Site Address: 3810 RIVERFRONT BLVD <br />Phone:3606710113 <br />e-Mail: expressadmin@expresselectric.com <br />Approve level one drop ceiling, North. level five north Corredor's corrections have been made. Panel directories are required in all panels, including the <br />electrical room near the north elevator bank. Labels need to be installed so as -to identify the house panel and the other unit smaller panel unit515 <br />ckt#10 AFCI inoperative, faulty test button. <br />6/5/2023 <br />6/5/2023 <br />ELEC 10-FINAL <br />MICHAEL <br />PARTIAL <br />as noted <br />WICKLANDER <br />APPROVAL <br />Notes: <br />6/2/2023 8:06 AM EXPRESS ELECTRIC INC <br />L5 units corridor for questions please contact Jed @360-410-5012 <br />Contact Name: EXPRESS ELECTRIC INC <br />Site Address: 3810 RIVERFRONT BLVD <br />Phone:3606710113 <br />e-Mail: expressadmin@expresselectric.com <br />building B, level 4, Approve unit 402-through 418; 401 master bath fixtures not yet installed. <br />�A_ <br />Printed: Tuesday, 12 September, 2023 15 of 21 rk <br />SUPERION <br />
The URL can be used to link to this page
Your browser does not support the video tag.