My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
8102 EVERGREEN WAY FINAL EVERETT 4 CORNERS 2025-08-04
>
Address Records
>
EVERGREEN WAY
>
8102
>
EVERETT 4 CORNERS
>
8102 EVERGREEN WAY FINAL EVERETT 4 CORNERS 2025-08-04
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/4/2025 9:24:20 AM
Creation date
8/4/2025 6:56:04 AM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
8102
Unit
FINAL
Tenant Name
EVERETT 4 CORNERS
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
739
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
oq <br />15. <br />twhare below. <br />a� <br />STA 91+76.OZ 1244' RT <br />(1) 4" DI GV, FLxMJ <br />(1) THRUST BLOCK <br />TOSLAND HALF ACRE GARDEN TRACTS <br />VOL. 11, PC. 101 <br />(1) 4" DI GV, FLxMJ <br />(1) THRUST BLOCK <br />AREA OF RELINQUISHMENT <br />REC. N0. 2046848 <br />AREA ACQUIRED BY <br />SUPERIOR COURT CASE <br />NO. 93074 <br />SW 1/4, SEC. 07, TWP. 28N., R05E, W.M. <br />0 <br />28050700302000 <br />28050700301700 <br />1. ALL WATER VALVES SHALL BE PROVIDED WITH VALVE BOX AND OPERATING NUT EXTENDED PER COE STD. DWG. 505. <br />2. MEGA LUGS SHALL BE INSTALLED AT ALL BENDS AND FITTINGS IN ACCORDANCE WITH COE STANDARDS. ALL PIPES AND FITTINGS SHOWN AS RESTRAINED JOINTS <br />(RJ) SHALL BE MEGALUG GASKET OR APPROVED EQUAL. <br />3. DOMESTIC WATER SERVICE SUPPLY SHALL INCLUDE A DOUBLE CHECK VALVE ASSEMBLY (DCVA) INSIDE BUILDING MECHANICAL ROOM W/MATERIALS AND CLEARANCES <br />PER COE STD. DWG. 520, REF. PROJECT PLUMBING PLANS/DETAILS. <br />4. THE CONTRACTOR SHALL VERIFY ALL SANITARY SEWER, DOMESTIC WATER, AND FIRE SERVICE CONNECTIONS SHOWN ON THIS PLAN WITH THE INFORMATION <br />PROVIDED IN THE PROJECT PLUMBING AND FIRE SPRINKLER PLANS/DETAILS AND NOTIFY ENGINEER OF ANY VARIANCES PRIOR TO CONSTRUCTION. <br />5. ALL WATER MAIN PIPES SHALL BE DUCTILE IRON, CLASS 52 WITH A MINIMUM COVER OF 36" UNLESS OTHERWISE NOTED AND APPROVED BY THE CITY. <br />6. COE WATER DEPT. CREWS SHALL MAKE ALL CONNECTIONS TO ACTIVE PUBLIC WATER MAINS UNDER SEPARATE UTILITY PERMIT. CONNECTION FEE SHALL BE BASED <br />ON A COST ESTIMATE BY THE WATER DEPT. AND WORK SHALL BE AT OWNERS EXPENSE. <br />FIRE SYSTEM NOTES <br />1. FIRE SERVICE SUPPLY LINE SIZES SHOWN ARE APPROXIMATE. ACTUAL LINE SIZES SHALL BE PER FIRE PROTECTION ENGINEER. <br />2. COE UTILITY SERVICES DEPARTMENT SHALL HAVE ACCESS TO MECHANICAL ROOMS DURING THE HOURS OF 7.30AM TO 4.00PM, MONDAY THROUGH FRIDAY. <br />4. FIRE SERVICE SUPPLY FOR ALL BUILDINGS SHALL INCLUDE A DOUBLE CHECK DETECTOR ASSEMBLY (DCDA) INSIDE BUILDING MECHANICAL ROOM PER COE STD. DWG. <br />523. ALL FIRE SPRINKLER SUPPLY LINES AND APPURTENANCES SHALL BE INSTALLED PER SECTION 5-17 OF COE DESIGN AND CONSTRUCTION STANDARDS AND <br />SPECIFICATIONS. FIRE SPRINKLER SYSTEM DESIGN AND CONNECTION DETAILS SHALL BE PROVIDED AND APPROVED UNDER SEPARATE PLUMBING PERMIT. <br />U � <br />CONSTRUCTION NOTES <br />r cc <br />O1 4" WATER SERVICE AND METER PER COE STD. DWI 00 <br />504 w/ 4" BACKFLOW ASSEMBLY WITHIN THE BLDI <br />(DCDA) PER COE STD. DWG. 523 <br />O SAWCUT, REMOVE AND REPLACE EXIST. PVMT. <br />O4" FIRE SERVICE SPRINKLER SYSTEM SERVICE LINE <br />(SEE FIRE SYSTEM NOTES) <br />O FIRE HYDRANT ASSEMBLY PER COE STD. DWG. 50'. <br />LEGEND <br />APPROX. 6" DI LENGTH PER PLAN <br />O POST INDICATOR VALVE (PTV) <br />cc <br />w <br />Y <br />6 FIRE DEPARTMENT CONN. (FDC) <br />0 <br />0 <br />3 <br />(n <br />U <br />1" IRRIGATION WATER SERVICE PER COE STD. DET. <br />O w/ 1" BACKFLOW ASSEMBLY (DCVA) PER COE STD <br />w <br />m <br />a <br />DET. 520. CONTRACTOR TO INSTALL <br />o <br />O PUBLIC UTILITY EASEMENT <br />o <br />POTHOLE EXIST. WATER MAIN TO VERIFY LOCA110A <br />O <br />o <br />8" SEGMENT <br />z <br />10 BLOW OFF ASSEMBLY PER COE STD. DET. 511 <br />if 1" AIR VAC VALVE ASSEMBLY PER COE STD. DET. <br />:rrraa.!��rai►.m�ya:��ra�r�.��a <br />FIRE DEPT. CONN. (FDC) <br />—F— FIRE SERVICE <br />F���I:i7d:>'►Idl <br />o SO CATCH BASIN <br />SS SANITARY SEWER MAIN <br />— — — — — — — SIDE SEWER SERVICE <br />SIDE SEWER CLEANOUT <br />1;'D:Irl�:a�711d1 <br />WATER SERVICE <br />— — — — PUBLIC UTILITY ESMT. <br />A FIRE HYDRANT (FH) <br />m BACKFLOW ASSEMBLY (DCVA) <br />k <br />0 30 60 <br />PLAN IN FEET <br />Copyright 0 2020 CPH Consultants, -LC. All Rights Reserved. <br />z <br />O <br />z <br />z_ <br />x <br />in <br />3 <br />z <br />z <br />U <br />2 <br />in <br />0 <br />O <br />x <br />O <br />z <br />rn <br />N <br />LLJ <br />a <br />Z <br />0 <br />0 <br />Z <br />U <br />a <br />J <br />W wm <br />Q w <br />3 <br />p <br />a <br />LL <br />O <br />LL <br />U <br />CLIENT <br />FOUR CORNERS, LLC <br />10900 NE 8TH STREET <br />SUITE 1200 <br />BELLEVUE, WA 98004 <br />PHONE: (425) 453-9551 <br />mm <br />CONSULTANTS <br />Site Planning • Civil Engineering <br />Landscape Architecture - Land Use Consulting <br />11321-B NE 1201h Street <br />laddand, WA 98034 - )425) 285-2390 <br />101 South Wenatchee Avenue, Suite C3 <br />Wenatchee, WA 98801 - )509) 293-7731 <br />www.cphconsuItants.com <br />PROJECT NO. <br />0024-18-042 <br />DRAWING <br />C5.02 <br />SHEET 34 OF 51 <br />
The URL can be used to link to this page
Your browser does not support the video tag.