Laserfiche WebLink
19011 Wood-Sno Road NE,Suite 100 <br /> BTL <br /> Woodinville,\X/A 98072-4436 <br /> Phone:425.814-8448 a <br /> ENGINEERING Fax;425-821-2120 <br /> Stud Wall Design <br /> Based on 2018 NDS Combined axial and bending formula: <br /> [fdF,]2+fb/Fe[1-(fdF,.E)]< 1 in which: F�,E=0.822(Emin')1(tjd)2 <br /> Wall: Interior Walls Wall Height: 9 ft <br /> Desired Stud Spacing: 24 in oc <br /> No Fire Rating ® Design Axial Dead Load: 203 plf <br /> 2A qV Design Axial Live Load: 640 pif <br /> SPF stud IV Design Axial Snow Load: 0 pif <br /> Design Lateral Pressure(0.6W): 5 psf <br /> Deflection Criteria: U 180 <br /> STUD CHECK Od < 50 OK <br /> D+0.6W(Co= 1.60) <br /> [fdF�]`+fb/Fjl-(fdF�)]= 0.41 < 1 OK <br /> if fdFa2+(fb/FbE)`= 0.00 < 1 OK <br /> D+0.75L+0.75(0.6W)+0,75S(CD= 1.60) <br /> [fjF,,]2+fdFe[1-(fdF,,E)]= 0.99 < 1 OK <br /> fdF�,u+(fb/FbE)`= 0.00 < 1 OK <br /> D+0,75L+0.75S (CD= 1.15) <br /> fdF,= 0.69 < 1 OK <br /> D+L A <br /> QF.= 0.86 < 1 OK <br /> Deflection(No Increase for Load Duration): <br /> Defl: U 180 = 0.60 0.23 < 0.60 OK <br /> to x oc <br /> Checks Crushing for Stud Spacing` <br /> No Stress Increase for Load Duration <br /> Hem Fir Plates: fjZ= 0.46 < 1 OK <br /> Douglas Fir Plates: fdFal= 0.30 < 1 OK <br /> ' Plate must also be checked for bending. <br /> 2 Check on crushing only applies to stud spacing. Joists above <br /> must also be checked for crushing effect on plate. <br /> Also, no stress increase is allowed due to load duration. <br /> Date: 1/27/2021 <br /> Page: M1 .3 <br />