Laserfiche WebLink
1401", ARMS 9512 7th Avenue Southeast <br /> Insulation <br /> Baffles installed in each rafter bay with soffit protection and extends along roof deck a Yes <br /> minimum of 18 inches above ceiling plane? <br /> Exterior walls W/Grade I insulation W/proper sealing &secured at fireplaces/tubs/chases? Yes <br /> Does the wall rim/band joist insulation have the correct R-value installed to Grade I or II? Yes <br /> Foam seal at corners, T-joints, top and bottom plates, chases, and all other points of air Yes <br /> infiltration? <br /> Windows and door frames air sealed? Yes <br /> Perimeter and garage floor blocking/draft stopping air sealed? Yes <br /> Inaccessible attic spaces have ceilings completely insulated or have access for blown-in attic Yes <br /> insulation <br /> Top plate Sealant installed per ESTAR or IECC code requirements? Yes <br /> Section Inspection Status - Insulation Pass <br /> Rating Verification <br /> Foundation Type Pier& Beam <br /> R-Value of Foundation Insulation N/A <br /> Does the house have a Crawl Space? Yes <br /> Crawl Space Yes <br /> Crawl Space - Type Vented <br /> Unvented height above grade N/A <br /> Exterior wall sheathing -Type Housewrap <br /> Exterior wall sheathing - In. Thickness 0.0 <br /> Exterior wall sheathing - R-Value R-0 <br /> Exterior wall cavity-Type Batt21 <br /> Exterior wall cavity- In.Thickness 5.50 <br /> Exterior wall cavity- Stud Spacing 16'' O.C. <br /> Exterior wall cavity- R-Value R-21 <br /> ,IYW <br /> J� <br /> i <br /> 10/14/2024 12:46 <br /> Exterior wall cavity- Grade 1 <br /> Garage - Type Batt <br /> Garage - In. Thickness 5.50 <br /> Page 3/6 <br />