Laserfiche WebLink
0 IIII SPECIFICATIONS <br /> F RAK90 <br /> Ventilation Products ® EXHAUST FANS <br /> • Cold rolled steel,powder coated white. \ <br /> T i______---fi e. <br /> �� `• Blower Wheel 4„ • <br /> One piece polymeric centrifugal blower wheel,5.22"diameter, <br /> 2.90'wide,with 30 paddles. 1 ► ( 7 I <br /> „ <br /> • Motor I <br /> Heavy duty,permanently split capacitor,4 pole motor,lifetime <br /> lubrication,thermally protected.Rated 120 volts,0.3 amps. <br /> • Contractor Pack(Motor/BladeGrill)Model:FAK9OT* 5/8„I <br /> • Fan Housing 5 „ — ——'__, <br /> 24 gauge galvanized steel housing,dimensions 103/4"x 91/4"x Ps". 10 h6 —�'1215/16„ <br /> Contractor Pack Model:AKFH2* <br /> • Damper <br /> • Duct Collar Blanket-Non-asbestos,ceramic blanket <br /> Metal collar for 4°duct connection,comes complete with built Fusible Link-Replaceable,165°F standard <br /> in back draft damper. Classification-Ceiling Radiation Damper is ULC classified <br /> ' • Ventilating Area and rated for a 3-4 hour fire resistance.U.L.listed 555C. <br /> For rooms up to 115 sq.ft. California State Marshall classification for 1 or 2 hour fire <br /> damper rating.California State Marshall listing number <br /> • Unit Mounting 3225 1374 101. <br /> FRAK90 is centered between joists(with 16"centers)using Contractor Pack Model:AKFD2* <br /> hanging brackets.The housing will mount through drywall <br /> thickness up to 3/4",with a rough-in opening of 103/4"x9V4". Qmca <br /> oO(RTI f D Air King Ventilation Products <br /> certifies that the models shown <br /> * herein are licensed to bear the <br /> Sold in packs of 4.All three parts(housing,damper,motor/blade/grill) AMCA seal.The ratings shown <br /> must be purchased and used together to make a complete unit. MUD are based on tests and procedures <br /> °t° performed in accordance with <br /> NYp11Wq AMCA Publication 211 and AMCA <br /> (.......----..„.\ nin Publication 311 and comply with <br /> .�y mo•tmcnr the requirements of the Certified <br /> _E�u�OaY`1 c nap conTnrn Ratings Program. <br /> C US n,,oannon <br /> ENERGY STAR firrennwrionnt.MC. <br /> AMCA LICENSED PERFORMANCE <br /> HVI Sones Fan Speed Power <br /> Static Pressure(inches of w.g.) @ Ps.1 SP RPM Watts <br /> 0 0.05 0.1 0.125 0.15 0.2 0.25 0.3 <br /> Air Flow-CFM 101 94 90 88 86 80 70 55 2.0 1250 32 <br /> Sound-SONES 2.7 2.9 2.9 2.9 2.9 3.0 2.9 3.1 <br /> Performance shown is for FRAK exhaust models for installation type B:Free inlet,Ducted outlet.Performance ratings include the effects of an inlet grille,ceiling radiation damper and backdraft <br /> damper in the airstream.Speed(RPM)shown is nominal.Performance is based on actual speed of test.The loudness ratings shown are loudness values in fan cones at 5 ft(1.5m)in a <br /> hemispherical free field calculated per AMCA standard 301.Values shown are for installation type B:free inlet fan sone levels.The AMCA Certified Ratings Seal does not apply to HVI Sones. <br /> LOCATION ENGINEER <br /> CONTRACTOR SUBMITTED BY DATE <br /> FAN MODEL CFM IN RPM WATTS AMPS SONES QTY OPTIONAL EQUIPMENT <br /> NUMBER NUMBER W.G. I &REMARKS <br /> . U.S.:820 Lincoln Drive•West Chester,PA 19380-4466•Tel:877-304-3785• Fax:(610)696-8048 <br /> Canada:110 Glidden Road • Brampton,Ontario L6T 2J3•Tel:(9051456-2033• Fax:(9051456-1015 <br /> Specifications subject to change without notice. FRAK80 Updated September 2007 <br />